M M cCann Structural BUILDING DEPARTMENT <br />-- -Solutions REVIEW -COMU MI NTS <br />T -- — RESPONSE LETTER <br />April 8, 2024 <br />Benjamin Monk, PE <br />Plans Examiner <br />City of Everett Public Works <br />3200 Cedar Street <br />Everett, WA 98201 <br />Subject: Architectural and Structural Comment Answers <br />B2211-046 <br />Ladd Stairs <br />3617 Oakes Ave. <br />Everett, 'WA 98201 <br />Dear Mr. Monk: <br />CITY OF EVERETT <br />Permit Services <br />In answer to the Architectural and Structural comments in your letter of March 4, 2024, <br />please consider the following responses: <br />Architectural Comments: <br />1. The existing window at the intermeNat stair landing shall be replaced with one that , <br />is compliant with Section 1015.8 of t�i 018 IBC to avoid creating moisture barrier <br />penetrations through the existing wv ll stru ure with a handrail. The existing <br />windows shall be replaced with ones that are not "operable", i.e., cannot be opened. <br />2. The handrail shown in Detail 2 of Sheet S6/8 has been modified to be compliant with <br />Section 1014.3 of the 2018 IBC. <br />Structural Comments: <br />1. A note will be added to the drawings to rotate and replace any existing hangers that <br />are not used in the intended vertical orientation, turning the members as appropriate <br />to achieve a vertical orientation for the hanger. An example of an HUC44, or a <br />hanger that is similar to an HUC44, and the associated 4X4 that needs to be rotated <br />relative to the existing column is included with this response as an example. <br />2. According to the calculations, on page 6A/17, 3 stringers will work with a five-foot <br />maximum stringer span, so the clouded statement on page 6A of the calculations and <br />the drawings are correct. No changes are needed. Regarding Sections 1603 and 1604 <br />of the 2018 IBC, the vertical and lateral requirements have been addressed. <br />A revised set of the stair drawings will be submitted along with this letter. <br />
The URL can be used to link to this page
Your browser does not support the video tag.