My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8102 EVERGREEN WAY 2020 EVERETT 4 CORNERS - BLDG A Plans 2025-06-20
>
Address Records
>
EVERGREEN WAY
>
8102
>
EVERETT 4 CORNERS - BLDG A
>
Plans
>
8102 EVERGREEN WAY 2020 EVERETT 4 CORNERS - BLDG A Plans 2025-06-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/20/2025 7:33:04 AM
Creation date
5/9/2025 10:56:40 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
8102
Tenant Name
EVERETT 4 CORNERS - BLDG A
Permit
B2010-048
Year
2020
Notes
FOUR CORNERS APTS - BLDG A-5, OVER 1 MULTIFAMILY RESID BLDG
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
100
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
a PRE-FAB SHOWER PAN <br /> COUNTERTOP AND FLOOR FINISH TO BE <br /> FLUSH WITH BOTTOM <br /> BACKSPLASH <br /> SLOPE OF SHOWER OHNSON BRAUND- <br /> (4)3/8"X 3 1/2"LAG SCREWS THRESHOLD SLOPE TO DRAIN <br /> N 17" 1• � 15200 52nd Ave.South <br /> 3/4"x 3"SUPPORT CLEAT PER MFR. _ Suite 300 <br /> REMOVABLE 1/2"x 3-5/8" Mom' Seattle,WA 98188 <br /> FACE TRIM-MATCH SEALANT Phone 206.766.8300 <br /> CABINETS vmvjonnsonnrauntl.wm <br /> GYPCRETE y ARCHITECTURE <br /> t / _ - INTERIOR DESIGN <br /> 3/4"x 3"SUPPORT CLEAT Greg L.Allwine, <br /> 3/4"PLYWOOD - -MOUNT BETWEEN VANITY FLOOR ASSEMBLY Jeffrey A.Williams, <br /> FINISHED TO I BRACE AND WALL OR ANOTHER <br /> VANITY CABINET m O <br /> MATCH CABINET i i __ o- w <br /> AND EDGE I 1 1 !^ <br /> BANDED. w m w INSULATE HOT 4 <br /> O N i <br /> z 2 _ N Z WATER AND DRAIN ? O 6" <br /> o.m o LINES U <br /> zU FRAMED SOFFIT-BELOW I-HR <br /> y 31/4" REMOVABLE CABINET FLR/CEILING ASSEMBLY(ONLY AS <br /> INDICATED ON UNIT PLANS) <br /> REMOVABLE CABINET <br /> TYPE I COUNTER BRACE PROVIDE WOOD TRIM IF GAP <br /> SEE DETAILS 15-16 THIS SHEET FOR i EXPOSED VENT-PAINT-BLACK ass. <br /> REMOVED CABINET CONDITION REGISTERED <br /> CLEAT AS REQ. ARCHITECT <br /> 16 ACCESSIBLE COUNTER BRACE-SECTION 12 REMOVABLE CABINET - <br /> 1" PROVIDE BLOCKING AT ALL <br /> I FFRF.Y ARTH[IR riII.I.IAM <br /> CABINET MODULES 36"WIDE OR sTnTe aF wnswucTOH <br /> UPPER LESS. <br /> LOCATE FULL HT.BLKG. ABINET <br /> 'I 'I LIGHT GAUGE FRAMED SOFFIT- sTP <br /> PER UNIT PLANS&INT. LL: BELOW 1-HR FLR/CEILING <br /> ELEVS.,TYP. ASSEMBLY(ONLY AS INDICATED ON k <br /> TYPE I COUNTER TYPE II COUNTER BRACE PRE-MANUFACTURED UPPER - <br /> REMOVABLE 1/2" BRACE(SIDE (SIDE ELEVATION) 15' UNIT PLANS) <br /> LL CABINET UNITS-SEE INTERIOR <br /> HARDWOOD TRIM ELEVATION)SEE TYPE II COUNTER BRACE MIN. TOP O SINK RIM ELEVATIONS. e t <br /> DETAILS THIS SHEET. CAN BE OF ANY w PROVIDE BLOCKING AT ALL qq <br /> 3/4"X3"$UPPORT CLEAT CONFIGURATION. > CABINET MODULES 36"WIDE OR o g <br /> LESS. <br /> TYPE I COUNTER BRACE WHERE LAVATORY ENCROACHES KNEE � z M - <br /> (4)3/8"X 3-1/2"LAG SCREWS REQ'D CLEAR FLOOR SPACE @ WATERCLOSET,BATHTUB OR SPACE g R <br /> PER DTL.THIS SHEET TURNING CIRCLE.TYPE II COUNTER BRACE @ ALL OTHER PRE-MANUFACTURED UPPER R <br /> LOCATIONS UNLESS INDICATED. 30" m <br /> CABINET UNITS-SEE INTERIOR <br /> ELEVATIONS. 141/4" <br /> (2)LAYERS 3/4"PLYWD. NOTES: MIN. <br /> GLUED,EDGEBANDED& 11" <br /> FINISHED TO MATCH 2X4-FULL 1. WATER TEMPERATURE SHALL NOT EXCEED 120'F. PRE-FORMED PLASTIC LAMINATE <br /> CABINETS HT.TYP. 2. HOT WATER&DRAIN PIPING TO BE INSULATED OR 25"(25 1/2"MAX. COUNTERTOP&TILE BACKSPLASH <br /> OTHERWISE CONFIGURED TO AVOID CONTACT. OR APPROVED. <br /> 3. MAXIMUM SINK BOWL DEPTH SHALL BE 6-1/2". <br /> 4. SELF-CLOSING FAUCET VALVES SHALL REMAIN OPEN 30'X48"CLR. PROVIDE BLOCKING AT ALL <br /> ——————— — —� FOR AT LEAST 10 SECONDS PER OPERATION. <br /> 0 <br /> 5. CABINETS MAYBE INSTALLED UNDER FLR.SPACE �� �' y LESS.CABINET MODULES 36"WIDE OR _ <br /> LAVATORIES/SINKS WITHIN DWELLING UNITS IF THE L_—_1 r <br /> CABINETRY IS EASILY REMOVABLE AND FLOORING o <br /> � 8"MIN. —— —-M 2"MIN.FILLER AT INSIDE BLIND o <br /> EXTENDS UNDER.(TYPE A UNITS,TYPICAL.TYPE B CORNER CABINETS-SEE INT.ELEV. <br /> CENTERLINE UNITS ONLY AS NOTED) KNEE 8 TOE i = <br /> OF SOLID 6. SEE ALSO ACCESSIBILITY NOTES ON SHEET A550. SPACE PRE MANUFACTURED BASE <br /> CLEARANCE <br /> BLKG. v12 <br /> CABINET UNITS-SEE INT.ELEV. <br /> r DIMENSTIONS 8 <br /> z 3„ FACE OF FINISHED WALL 3 CABINET SYSTEM-SOFFIT FRAMING <br /> m �— 24"BOX <br /> y��" PLUS DOOR m <br /> 15 ACCESSIBLE COUNTER BRACE-PLAN 11 ACCESSIBLE COUNTER&SINK 11"MIN! T'MAX. � CABINET SYSTEM PROFILE-TYPE B <br /> 3"=1'-0" 114"=V-0" 1/2"=1111, > <br /> EXTENT OF NOW C <br /> ABSORBENT MATERIAL <br /> LIGHT GAUGE FRAMED SOFFIT- <br /> MIDPOINT OF TUB TOP OF GRAB NOTE BELOW 1-HR FLR/CEILING <br /> 4"MAX. BAR 3 ASSEMBLY(ONLY AS INDICATED ON <br /> r 2" 12" NOTE 3 NOTE UNIT PLANS) 3 <br /> ® TOP OF TOP OF - _ L 2 <br /> ——NOTE 1 w PROVIDE BLOCKING 6"ALL o z 12" 24" 24" co z TOP OF G.B. <br /> GRAB GRAB � � > CABINET MODULES 36"WIDE OR <br /> BA Z Z rR LESS. <br /> to <br /> PRE-MANUFACTURED UPPER <br /> QU CABINET UNITS-SEE INTERIOR 12 <br /> ro ro ELEVATIONS. <br /> r TOP OF SEAT y <br /> Z ® Q NOTES: 36"MIN. <br /> 2 NOTE 1 <br /> A PRE-FORMED PLASTIC LAMINATE C <br /> 1. VANITY CAN OVERLAP REQ'D CLR.FLR. IN 24" 24' MAX. 1 COUNTERTOP&TILE BACKSPLASH F <br /> � <br /> 2q- SPACE DWELLING UNITS ONLY. IN. MIN. OR APPROVED. E <br /> �i� 2. REAR GRR AB BAR CAN BE 24"IN <br /> NOTES: r------ DWELLING UNITS WHERE WALL SPACE F.LR <br /> z DOES NOT ALLOW FOR 36"(ICC NNOTE 1 PROVIDE BLOCKING AT ALL1. TYPE BUNITS/OPTION A BATHROOMS: 4"MAX. A117.1-2009,1004.11.1,EXC.3). CABINET MODULES 36"WIDE ORTOILET CAN ENCROACH THE REQUIRED - i 3 IN TYPE B UNITS,WHERE FIXTURES i w w LESS. <br /> 48"X 60"CLEAR FLOOR SPACE @ TUB. ARE LOCATED ON EACH SIDE,A 2"MIN.FILLER AT INSIDE BLIND2. TYPE BUNITS/OPTION B BATHROOMS: SWING-UP GRAB BAR IS PERMITTED 6+ 48"X56"CLR. n CORNER CABINETS-SEE INT.ELEV.NO ENCROACHMENTS IN REQUIRED 30"X _ ON THE16"-18"SIDE. FLR.SPACE �gFINISH FLOOR 48"CLEAR FLOOR SPACE POSITIONED AT PRE-MANUFACTURED BASE :¢CONTROL END OF TUB. L———— CABINET UNITSSEE INT.ELEV. �30 oDIMENSION IS 46"MAX.A.F.F.AND LOCATED 36"MIN.FROM CLEAR . 1 w>d a <br /> INSIDE CORNERS IN KITCHENS(SIDE REACH OVER COUNTERTOP), FLOOR 48" 3' FACE OF FINISHED WALL C o m w <br /> TYPICAL SPICE-SEE4"MIN. P 23"BOX O m w> z w rc <br /> 3 <br /> m v wk <br /> 14 RECEPTACLE MOUNTING HEIGHTS 10 s �z�CABINET SYSTEM PROFILE-TYPE A (,� m°' 3m <br /> w o.m ¢ zW <br /> 1 1/2"=V-0" z <br /> ZI N ABSORBENT <br /> T 0 ¢ wUoi �G <br /> 1. GRAB BARS SHALL HAVE AN OUTSIDE DIAMETER OF NOT LESS THAN MATERIAL L u$m <br /> 1-114"OR MORE THAN 1-1/2"AND SHALL PROVIDE A CLEARANCE OF <br /> 1-1/2"BETWEEN THE GRAB BAR AND THE WALL. MIDPOINT OF TUB <br /> 2. TOP OF GRAB BARS SHALL BE LOCATED NOT LESS THAN 33"AND NOT 4"MAX. TOP OF GRAB <br /> UI MORE THAN 36"ABOVE THE FLOOR OF THE ADJACENT CLEAR SPACE. BAR NOTE 3 <br /> ` 3. THE STRUCTURAL STRENGTH OF GRAB BARS,TUB AND SHOWER F <br /> y SEATS,FASTENERS AND MOUNTING DEVICES SHALL MEET THE TOP OF w TOP OF 2„ 12' NOTE 2 <br /> FOLLOWING REQUIREMENTS. z 12" 24" 24" eo z T.P.DISPENSER <br /> EO GRAB Z GRAB M BLOCKING TOP OF G.B. NOTE 1 <br /> U A. BENDING STRESS INDUCED IN A GRAB BAR OR SEAT BA ? rR INDUCED BYTHE MAXIMUM BENDING MOMENT FROM THEp APPLICATION OF 300 POUNDS SHALL BE LESS THAN THE - w CONTROLEXTERIOR INTERIOR <br /> IL ALLOWABLE STRESS FOR THE MATERIAL OF THE GRAB AREA „ � DOOR FRAME& <br /> BAR OR SEAT. TYPE A Q o Q DOOR AS <br /> � B. SHEAR STRESS INDUCED IN A G.B.OR SEAT BY THE ? UNITS ro ro A N B SCHEDULED <br /> APPLICATION OF 300 POUNDS SHALL BE LESS THAN THE 36"MIN. <br /> ALLOWABLE SHEAR STRESS FOR THE MATERIAL OF THE Q Q '15"-17"IN DWELLING UNITS 70P OF SEAT NOTE 3 <br /> y G.B.OR SEAT.IF THE CONNECTION BETWEEN THE G.B.OR NOTES: 12" 24" LOW PROFILE MTL. <br /> E SEAT AND ITS MOUNTING BRACKET OF OTHER SUPPORT THRESHOLD&COMP. <br /> NOTES 24„ 1. VANITY CAN OVERLAP REQ'D CLR. IN. MIN. <br /> IS CONSIDERED TO BE FULLY RESTRAINED,THEN THE g 1g^ WEATHERSTRIP W. <br /> O DIRECT AND TORSIONAL SHEAR STRESSES SHALL BE 1. TOILET CAN ENCROACH THE REQUIRED CLEAR FLOOR ----- FLR.SPACE @ DWELLING UNITS ,{ SEALANT PROJECT#: 1827 <br /> 0 TOTALED FOR THE COMBINED SHEAR STRESS,WHICH iv ONLY.KNEESPACE(OR REMOVABLE <br /> SPACE @TUB IN TYPE BUNITS. F12 <br /> is SHALL NOT EXCEED THE ALLOWABLE SHEAR STRESS. CAB)REQ'D @ TYPE A UNITS.TYPE A DRAWN BY: GLEE <br /> 2. AT TYPE A UNITS:A HAND SHOWER WITH A HOSE 59" 4'MAX. <br /> m C. SHEAR FORCE INDUCED IN A FASTENER OR MOUNTING z UNITS WIOVERLAP REQUIRES MIN.LENGTH THAT CAN BE USED BOTH AS A FIXED `v60"X66"CLR.FLR.SPACE. F.F. CHECKED BY: ST <br /> DEVICE FROM THE APPLICATION OF 300 POUNDS SHALL SHOWER HEAD AND AS A HAND SHOWER SHALL BE I � z F.F.BE LESS THAN THE ALLOWABLE LATERAL LOAD OF EITHER PROVIDED.THE HAND SHOWER SHALL HAVE A 2. FLUSH CONTROL SHALL BE NOTE 1 <br /> THE FASTENER OR MOUNTING DEVICE OR THE 30"X6U' MOUNTED FOR USE FROM THE OPEN , INTERIOR& <br /> CONTROL WITH A NONPOSITIVESHUT-OFF FEATURE. SIDE OF THE WATERCLOSET AREA. a DOORS TO ACCESSIBLE SPACES SHALL HAVE ASUPPORTING STRUCTURE,WHICHEVER IS THE SMALLER AN ADJUSTABLE HEIGHT SHOWER HEAD MOUNTEDONA `"' PEAUNIT) X DOORTHRESHESSIBLOLD HAMAXI SHALLUM AVEAHT ACCESSIBILITY <br /> ALLOWABLE LOAD. VERTICAL BAR SHALL BE INSTALLED SO AS NOT TO (TY` 3. REAR GRAB BAR CAN BE 24"IN 1/2"PER PER ICC/ANSI 117.1 SEC.404.2.4. DETAILS <br /> D. TENSILE FORCE INDUCED INA FASTENER BY A DIRECT OBSTRUCT THE USE OF GRAB BARS.TENSION FORCE OF 300 POUNDSPLUS THEMAXIMUM 3. CONTROL AREA RESTRICTION FOR TYPE A UNITS ONLY. DWELLINGUNITS WHERE WALL 60"X66"CLR.FLR.SPACE CHANGES IN LEVEL GREATER THAN 1l4"IN HEIGHT <br /> MOMENT FROM THE APPLICATION OF 300 POUNDS SHALL S D E O A O F W/VANITY OVERLAP AND NOT MORE THAN 1/2"MAX.IN HEIGHT SHALL BE <br /> BE LESS THAN THE ALLOWABLE WITHDRAWAL LOAD 12"MIN. 1 60 BEVELED WITH A SLOPE NOT STEEPER THAN 1:2 q 5 5 0 <br /> BETWEEN THE FASTENER AND THE SUPPORTING PER ICC/ANSI A117.1 SEC.303.3 <br /> w STRUCTURE. <br /> 1 <br /> w 13 GRAB BAR REQUIREMENTS ��ACCESSIBLE BATHTUBUNIT � ACCESSIBLE DOOR THRESHOLD PERMIT SET 10/09/2020 <br /> LL 1'..=1'-0" 1/4"=T-0" 1/4"=111" 1 112"=V-0" <br />
The URL can be used to link to this page
Your browser does not support the video tag.