Laserfiche WebLink
Q <br /> CEILING PLAN LEGEND&NOTES ''II11`` <br /> a <br /> 1 CENTER GRID IN ROOM OR VV <br /> coRRIDGR,u.N.o. OHNSON BRAUND- <br /> 2. GWB CEILING TO BE ATTACHED 15200 52nd Ave.South <br /> TO UNDERSIDE OF FLOOR Suite 300 <br /> FRAMING,U.N.O. Seattle,WA 98188 <br /> 3. SEE MECHANICAL SHEETS FOR Phone 206.766.8300 <br /> LOCATION OF DUCTS,FIRE vmvjohnsonhmund— <br /> DAMPERS AND COMBINATION ARCHITECTURE <br /> FIRE/SMOKE DAMPERS INTERIOR DESIGN <br /> 4. SEE ELECTRICAL DRAWINGS Greg L.Allwine, <br /> FOR LOCATION OF EXIT SIGNS, Jeffrey A.Williams, <br /> INCLUDING LOW-LEVEL EXIT <br /> SIGNS,AND SMOKE DETECTORS <br /> 5. CENTER SPRINKLER HEADS ON <br /> CEILING TILES <br /> 6. SEE SHEETS A040 AND A041 <br /> FOR ASSEMBLY TYPES <br /> 7. NFPA 13 FIRE SPRINKLER SYSTEM TO BE <br /> DESIGN-BUILD <br /> 8. NFPA 72 FIRE ALARM SYSTEM TO BE <br /> DESIGN BUILD <br /> 9. PROJECTIONS INTO THE ACCESSIBLE <br /> PATH OF TRAVEL BY WALL SCONCES ass. <br /> AND OTHER SUCH DEVICES BETWEEN REGISTERED <br /> THE HEIGHT OF 27"AFF AND 80"AFF ARE ARCHITECT <br /> LIMITED TO 4"IN DEPTH. <br /> I FFRF.Y ARTH[IR riII.I.IAM <br /> STATE OF WASHINGTON <br /> Room name CEILING TAG STAMP <br /> 101 <br /> k <br /> GYPSUM WALLBOARD <br /> CEILING s <br /> et <br /> CEILING HEIGHT MARKER <br /> R <br /> a a <br /> Nod <br /> RETURN REGISTER <br /> SUPPLY DIFFUSER <br /> CIL MOUNTED EXIT SIGN <br /> W/DIRECTIONAL ARROW <br /> 0 <br /> q 5 WALL MOUNTED EXIT SIGN <br /> 12 <br /> A412 3 WALUCEILING EXIT SIGN BASIS OF DESIGN: o <br /> A41P NAVILITE NXPB-3-G-WH 90 MIN.BATTERY <br /> BACK-UP.GREEN LETTERING <br /> MAX I <br /> GWB <br /> —_—_—_—_ A410 — — — ——— <br /> — <br /> T R#2 p <br /> a <br /> ST-2 DI GONAL HATCH INDICATES ADA g <br /> 8'-81/2' VVERTICAL CLEARANCE AREA. f <br /> GWB GWB 1 MddddddlNTAIN 8'-2"MIN FINISHED CLEAR 1 0 <br /> 3'-9" <br /> IN HIS AREA a <br /> zo <br /> � w <br /> Ea <br /> '-0 <br /> 2 A312 2 -€ <br /> � <br /> EXIT SIGNS TO BE 8'-2"MIN.TO BOTTOM La <br /> OF SIGN.PROVIDE R30 RIGID INSULATION 3 <br /> SIGN LOCATIONS TO ENSURE GI e <br /> COMPLIANT SIGN ISNTALLATION. = ry <br /> ZI COLUMN CAPS PER A.5 V a Z U S dW <br /> II 3 <br /> m1 STRUCTURAL.WRAP WITH 8'-21/4" a—i O u a m Fg <br /> R-30 RIGID INSULATION <br /> TP <br /> I I <br /> 0 <br /> p A310 827 <br /> DRAWN BY: 1 AT <br /> X <br /> m <br /> CHECKED BY: ST <br /> j BLDG A-GARAGE <br /> U WEST-RCP <br /> w A217A <br /> Z �I�BLDG A-GARAGE WEST-RCP <br /> PERMIT SET 10/09/2020 <br /> w <br /> 1 1/8"=T-0" <br />