"J"TRIM(TYP.) <br /> �I 1/4"RADIUS EDGES 3/4"PLYWOOD RISER(TYP.) <br /> EXTERIOR STAIR ENCLOSURE +42"ABOVE STAIR <br /> a J NOSE&LANDING <br /> J/j PLYWOOD STAIR TREAD(TYP.) <br /> 2HR STAIR ENCLOSURE 2 LAYER TYPE X 9A 9A 2"WIDE VINYL STAIR NOSING TO 1"MAX <br /> WALL.NO PENETRATIONS 7J 5/8"GWB CONTRAST WITH STAIR FINISH 77" PROJECTION OHNSON BRAUND <br /> INC. <br /> 5/4 x 6 HARDWOOD CAP TRIM 15200 52nd Ave.South <br /> PERMITTED. PER <br /> BASE AS SELECTED ( ) �NU E 6 -U—G'Q 504.5�CIANSI A717.1 SECTION300 <br /> PAINT EDGE BLACK TYP. Suite e, <br /> Ni- 6 Phone 206.766.8300 <br /> PLYWOOD,PER A490 Seattle,WA 98188 <br /> 1/2 x 4 HARDWOOD TRIM CONNECTOR-SEE <br /> STRUCTURALF73 STRUCTURAL w,mw.johnsonbraund— <br /> ARCHITECTURE <br /> I <br /> STAIR LANDING 1"GYPCRETE INTERIOR DESIGN <br /> FULL WIDTH BASE AS SELECTED Greg L. <br /> A.IIm.,Jeffrms, <br /> 2x4 STUDS @ 16"O.C. PLYWOOD TREAD <br /> 1_0" <br /> W/5/8"TYPE"X"GWB <br /> FRAMING PER STUDS @ EACH END STAIR FINISH <br /> STRUCTURAL 1 OF WALL <br /> I <br /> I 11 I P <br /> fl <br /> GIRDER PER HANGER PER TRUSS <br /> TRUSS MANUF'R MANUPR <br /> 2x BLOCKING IN LINE (1)LAYER 5/8"TYPE <br /> NAILER FOR CEILING FINISH 7J PSL+1 1/2'ENGINEERED WITH STAIR STRINGER e a PSL X"GWB gyp.) <br /> WOOD,NO SPACE=6 <br /> 3/4"WIDE HEAVY TIMBER <br /> 1 LAYER TYPE X 2HR STAIR ENCLOSURE <br /> GWB STRINGER-SEE asss <br /> 7J WALL. PENETRATIONS BEAM STRUCTURAL BEAM-SEE REGISTERED <br /> PERMITTED. <br /> R-10 SPRAY-IN <br /> STRUCTURAL ARCHITECT <br /> _ " <br /> FOAM INSULATION CORRIDOR STAIR ENCLOSURE 2x4 BLOCKING <br /> I FFRF.Y ARTH[IR riII.I.IAM <br /> \ STATE OF WASHINGTON <br /> �2 \MID"LANDING AT EXTERIOR WALL 12 A490 TRUSS BEARING 2 HOUR WALL STAIR GUARDRAIL r4� BOTTOM OF STAIR(a LANDING <br /> 1 1/2"=V-0" 1 1/2"=T-0" 1 1/2"=1'0" 1 1/2"=1'-0" STAMP <br /> 2"WIDE VINYL STAIR NOSING TO <br /> 1"PLYWOOD 1„ CONTRAST WITH STAIR FINISH PER k <br /> STAIR TREAD ICC/ANSI At 17.1 SECTION 504.5.1 <br /> AIR GAP CONNECTOR SEE s <br /> CORRIDOR STAIR ENCLOSURE 1"EMAX <br /> CTI /'STRUCTURAL a t <br /> LEDGER PER PROJECTION <br /> STRUCTURAL 2HR STAIR ENCLOSURE 1' 1/4' +36"ABOVE STAIR/` 3/4"PLYWOOD 11" 1"GYPCRETE o' <br /> PT SLAB-SEE FLOOR WALL.NO PENETRATIONS 7J NOSE 8 LANDING RISER(TYP.) <br /> ASSEMBLIES STRUCTURAL PERMITTED. (2)5/8"EXTERIOR DENS <br /> CONNECTOR BASE AS SELECTED GOLD TYPE"X" R <br /> PLYWOOD STAIR R <br /> SHEATHING TO BE V TREAD(TYP.) G7 <br /> - e. 2"CONTRASTING WALL BEYOND�ti PLYWOOD,PER APPLIED DURING rn <br /> COLOR VINYL STAIR STRUCTURAL FRAMING BASE AS SELECTED <br /> NOSING <br /> ` gp STAIR LANDING <br /> 2HR STAIR PLYWOOD TREAD <br /> ENCLOSURE @SIM:ROOF <br /> - - 3/8"PLYWOOD WALL.NO AT <br /> RISER PENETRATIONS STAIR FINISH " <br /> PERMITTED. srer Psi o <br /> --__------- h - <br /> FRAMING PER <br /> FULL WIDTH STRUCTURAL `u <br /> 1"PLYWOOD d <br /> FURRING CHANNELS STAIR TREAD BLOCKING IN LINE <br /> WITH STAIR BEAM-SEE <br /> 2X BLOCKING 514x STRINGER,PER STRUCTURAL <br /> 11 /e SL STRUCTURAL 2x4 BLOCKING <br /> 1 LAYER TYPE X 518"GWB 7F 2X4 UNIT WALL (i)LAYERS 5/8"TYPE <br /> CONSTRUCTED AS "X"GWB(TYP.) <br /> CLG.PER7 1/2 OF <br /> PSL+11/2"ENGINEERED <br /> 7D m RCP FRAMING PER 7JI WOOD,NO SPACE=6 0 <br /> STRUCTURAL WIDE HEAVY TIMBER GWB CONTINUOUS <br /> BEAM 7J ��TOP OF STAIR(il LANDING d <br /> (1)LAYERS 5/8'. <br /> TYPE"X"GWB 1 1/2"=T-0" <br /> 15 STRINGER AT PT CONCRETE SLAB 11 STAIR as CORRIDOR WALL @SIM:HANGER FOR <br /> ROOF JOIST <br /> 1 1/2"=V-0" 1 1/2"=P-0" 1'-1 1/4" 1.Stairway identification-approved stairway identification signs shall be located at each floor level ° <br /> STAIR STRINGER- 3 <br /> SEE STRUCTURAL <br /> in all enclosed stairways in buildings four or more stories in height.The sign shall identify the <br /> UNIT STAIR ENCLOSURE r7�STAIR(�WALL stairway,indicate whether there is roof access,the floor level,and the upper and lower terminus <br /> AIR GAP of the stairway.The sign shall be located 5 feet above the floor landing in a position which o <br /> 7F 2X4 UNIT WALL 2HR STAIR ENCLOSURE WALL.NO 1 1/2"=V-0" provides uninterrupted visibility when the door is in the open or closed position. <br /> CONSTRUCTED AS PENETRATIONS PERMITTED. <br /> 1/2 OF 7D 7J 2.The sign shall be a minimum of 12 inches x 18 inches. <br /> (2)5/8"EXTERIOR BASE AS SELECTED 1 1/4"PAINTED 3.The stairway location shall be placed at the top of the sign in 1 1/2 inch high block lettering <br /> DENS GOLD TYPE X 1 1/2" HARDWOOD with 3/8"stroke("SOUTH STAIR"or"NORTH STAIR"). <br /> SHEATHING TO BE PLYWOOD,PER STRUCTURAL HANDRAIL N w <br /> 'THRUST BLOCK'w/ APPLIED DURING 4,The stairway's upper terminus shall be placed under the stairway identification in 1 inch high <br /> ANCHOR BOLTS-REF FRAMING 8D 1 STAIR LANDING +36"ABOVE STAIR block lettering with 1/4"stroke("ROOF ACCESS"or"NO ROOF ACCESS"). <br /> STRUCTURAL NOSE 8 LANDING 1111i <br /> 5 The floor level number shall be placed in the middle of the sign in 5 inch high lettering with a rc <br /> FINISH FLOOR 3/4"stroke.Any garage level shall have the letter"G"preceding the floor number. E E <br /> g€ <br /> 6.The lower and upper terminus of the stairway shall be placed at the bottom of the sign in 1 inch C <br /> FRAMING R high block lettering with 1/4"stroke. g- <br /> STRUCTU L FRAMING PER BRACKET W/ <br /> STRUCTURAL ESCUTCHEON PLATE @ 7.These signs shall be maintained in an approved manner. 3 c LL <br /> 'n PLATE @CONCRETE.-,; SO O.C.MAX.- <br /> ,TO BE PRESSURE a BOLT TO BLOCKING y m rn <br /> _ .,TREATED <br /> 2x8 BLOCKING 1 1/2"LETTERING[ EAST STAIR #1 n ¢ w m® <br /> BLOCKING PER PSL+1/4"PLYWOOD,NO STRUCTURAL 7J SPACE= <br /> / g \HANDRAIL 1-LETTERING[ ROOF ACCES 3w 51/2"WIDE <br /> X 14 A490 BOTTOM OF STAIR AT PT SLAB RIMBOARD HEAVY TIMBERGEAM 3"=1'-0" y a t Q zw <br /> 11/2"=r-13" UNIT APPROVED FIRE STAIR ENCLOSURE SANSERIFOR L. ❑ a�w� 3z <br /> ml BLOCKING HELVETICA a w U zo d or <br /> Z <br /> ml STAIR ENCLOSURE BLOCK �L w z a <br /> 10 STAIR LANDING a12 UNIT WALL 5"LETTERING LETTERING a-i u$m Fg <br /> 1 1/2"=T-0" 18"MIN.CLR FLR SPACE CENTERED <br /> UI 2HR STAIR ENCLOSURE WALL.NO ON TACTILE,CHARACTERS PAINT REVEAL EDGE Sl4 x 6 HARDWOOD CAP TRIM <br /> PENETRATIONS PERMITTED. 4" (TYP-)BLACK <br /> LETTERING[ 1 TH RU <br /> 3" ill" 1/4"RADIUS EDGES <br /> ❑ BASE AS SELECTED 12"x18'SIGN <br /> U (DENS GOLD TYPE X 1/2 x 4 HARDWOOD TRIM "J"TRIM(TYP.) <br /> PLYWOOD,PER <br /> 3 SHEATHING TO BE 2.4 STUDS @ 16"O.C.W/ <br /> ❑ 1 STRUCTURAL _ 5/8"TYPE"X"GWB EA. <br /> ri APPLIED DURING - E��T SIDE-DOUBLE STUDS@ <br /> r FRAMING STAIR LANDING <br /> EACH END OF WALL <br /> �< OF DOUB LTST EA.SIDE 1 1/2"LETTERING[ WEST STAIR #2 w'OF DOUBLE STUDS <br /> W @ ENDS OF WALL BASE AS SELECTED <br /> E u Lim (2)10d NAILS @ 16" 1"LETTERING[ ROOF ACCES <br /> o UNIT NAILER a d O.C. PROJECT#: 1827 <br /> p NOTES: SHIM SANSERIF OR <br /> j� 1. 4"WIDE x 3"HIGH x 1/8"THICK SIGN FINISH FLOOR HELVETICA DRAWN BY: AT <br /> d) 7F MOUNTED AT STRIKE SIDE OF EXIT DOORS. BLOCK <br /> 2X4 UNIT WALL a CHECKED BY: ST <br /> g CONSTRUCTED AS 2. LETTER CHARACTERS TO BE RAISED 1/32"z 1/2 OF LETTERING <br /> AC HIGH UPPER CASE, SERIF TYPE AND 5"LETTERING <br /> y 7D ACCOMPANIED BY GRADE <br /> 2 2 ROUNDED OR <br /> DOMED SHAPED BRAILLE BEAM-SEE STRUCTURAL <br /> 3. BRAILLED CHARACTERS TO CONFORM WITH STAIR DETAILS <br /> Ci <br /> PSL+1/4"PLYWOOD,NO STANDARD DIMENSIONS FOR LITERARY <br /> 7J SPACE=51/2"WIDE BRAILLE AND AS INDICATED IN 20091CC/ANSI 1"LETTERING[ 1 TH RU <br /> 3.4 <br /> HEAVY TIMBER BEAM A117.1.E SIG <br /> 4. LOCATE SIGN AT EACH REOIURED EXTERIOR AA ///��� <br /> w STAIR ENCLOSURE EXIT DOOR AND AT DOORS TO EXIT STAIRS. (1)LAYERS TYPE"X �� 0 <br /> (EXTERIOR DOORS WITH ILLUMINATED EXIT GWB 12"x18"SIGN <br /> SIGN ABOVE.) <br /> w 13 INT.LANDING na UNIT WALL �9�TACTILE EXIT SIGN �5� LOW WALL(a�STAIR LANDING �j�STAIRWAY IDENTIFICATION PERMIT SET 10/09/2020 <br /> LL 1 1/2"=1'-0" 6"=1'-0" 1"=1'0" 3"=1'-0" <br />