Laserfiche WebLink
a \I <br /> COUNTERTOP AND <br /> BACKSPLASH <br /> OHNSON BRAUND- <br /> (4)3/8"X 3 1/2"LAG SCREWS 17" 15200 52nd Ave.South <br /> 3/4"x 3"SUPPORT CLEAT Suite 300 <br /> REMOVABLE Il'x 3-5/8" MAX' SeatBe,WA 98188 <br /> FACE TRIM-MATCH Phone 206.766.8300 <br /> CABINETS —phnsonhraund— <br /> ARCHITECTURE <br /> t / INTERIOR DESIGN <br /> 3/4"x 3"SUPPORT CLEAT Greg L.Allwine, <br /> 3/4"PLYWOOD - -MOUNT BETWEEN VANITY Jeffrey A.Wllllama, <br /> FINISHED TO I BRACE AND WALL OR ANOTHER <br /> VANITY CABINET to O <br /> MATCH CABINET i i __ w <br /> AND EDGE it it <br /> BANDED. w m w INSULATE HOT O w z <br /> Z WATER AND DRAIN z <br /> y o LINES O 14" <br /> zU FRAMED SOFFIT-BELOW I-HR <br /> y g1/q^ REMOVABLE CABINET FLR/CEILING ASSEMBLY(ONLY AS <br /> INDICATED ON UNIT PLANS) <br /> REMOVABLE CABINET <br /> TYPE I COUNTER BRACE PROVIDE 3 S WOOD TRIM IF GAP <br /> SEE DETAILS 15-16 THIS SHEET FOR i EXPOSED VENT-PAINT-BLACK ass. <br /> REMOVED CABINET CONDITION REGISTERED <br /> CLEAT AS REQ. ARCHITECT <br /> 16 ACCESSIBLE COUNTER BRACE-SECTION 12 REMOVABLE CABINET - <br /> 1" PROVIDE BLOCKING AT ALL <br /> I FFRF.Y ARTH[IR riII.I.IAM <br /> CABINET MODULES 36"WIDE OR sTATe aF wnswucTOH <br /> UPPER LESS. <br /> ABINET sTAMv <br /> LOCATE FULL HT.BLKG. <br /> PER UNIT PLANS&INT. <br /> ELEVS.,TYP. k <br /> TYPE COUNTER TYPE II COUNTER BRACE 15, PRE-MANUFACTURED UPPER <br /> REMOVABLE 1/2" BRACE(SIDE (SIDE ELEVATION) CABINET UNITS-SEE INTERIOR <br /> HARDWOOD TRIM ELEVATION)SEE TYPE II COUNTER BRACE MIN. TOP O SINK RIM ELEVATIONS. e t <br /> DETAILS THIS SHEET. CAN BE OF ANY <br /> 3/4"X3"SUPPORT CLEAT CONFIGURATION. o't <br /> TYPE I COUNTER BRACE WHERE LAVATORY ENCROACHES KNEE z M <br /> (4)3I8"X 3-1/2"LAG SCREWS REQ'D CLEAR FLOOR SPACE @ WATERCLOSET,BATHTUB OR SPACE R <br /> PER DTL.THIS SHEET TURNING CIRCLE.TYPE II COUNTER BRACE @ ALL OTHER <br /> LOCATIONS UNLESS INDICATED. 30" rn <br /> (2)LAYERS 3/4"PLYWD. NOTES: MIN. 141/4 <br /> GLUED,EDGEBANDED& <br /> FINISHED TO MATCH 2X4-FULL 1. WATER TEMPERATURE SHALL NOT EXCEED 120'F. <br /> CABINETS HT.TYP. 2. HOT WATER 8,DRAIN PIPING TO BE INSULATED OR <br /> OTHERWISE CONFIGURED TO AVOID CONTACT. <br /> 3. MAXIMUM SINK BOWL DEPTH SHALL BE 6-1/2". <br /> 4. SELF-CLOSING FAUCET VALVES SHALL REMAIN OPEN 30"X48"CUR. <br /> FOR AT LEAST 10 SECONDS PER OPERATION. FLR.SPACE ° <br /> 5. CABINETS MAY BE INSTALLED UNDER <br /> LAVATORIES/SINKS WITHIN DWELLING UNITS IF THE L_-_J '- <br /> CABINETRY IS EASILY REMOVABLE AND FLOORING 8"MIN. d <br /> _ EXTENDS UNDER.(TYPE A UNITS,TYPICAL.TYPE B o <br /> CENTERLINE UNITS ONLY AS NOTED) KNEE 8 TOE <br /> OF SOLID 6. SEE ALSO ACCESSIBILITY NOTES ON SHEET A550. SPACE <br /> BLKG. CLEARANCE <br /> N DIMENSTIONS \ <br /> � z 3 \CABINET SYSTEM-SOFFIT FRAMING <br /> 15 ACCESSIBLE COUNTER BRACE-PLAN 11 ACCESSIBLE COUNTER&SINK 11"MIN6"MAX. O <br /> 3"=1'-0" 114"=T-0" <br /> C <br /> y 11" 1111" I� <br /> 'I 'I LIGHT GAUGE FRAMED SOFFIT- 'I 9 LIGHT GAUGE FRAMED SOFFIT- <br /> BELOW 1-HR FLR/CEILING BELOW 1-HR FLR/CEILING <br /> ASSEMBLY(ONLY AS INDICATED ON ASSEMBLY(ONLY AS INDICATED ON <br /> UNIT PLANS) UNIT PLANS) g <br /> w PROVIDE BLOCKING AT ALL w PROVIDE BLOCKING AT ALL o <br /> > CABINET MODULES 36"WIDE OR > CABINET MODULES 36"WIDE OR <br /> LESS. LESS. a <br /> zo <br /> PRE-MANUFACTURED UPPER PRE-MANUFACTURED UPPER <br /> CABINET UNITS-SEE INTERIOR CABINET UNITS-SEE INTERIOR <br /> ELEVATIONS. ELEVATIONS. <br /> z Do w <br /> 11' PRE-FORMED PLASTIC LAMINATE 11" <br /> COUNTERTOP TILE BACKSPLASH PRE-FORMEDCOUNTERTO &LTILEIBACK PLASH <br /> OR APPROVED. G> <br /> OR APPROVED. E` <br /> z PROVIDE BLOCKING AT ALL <br /> PROVIDE BLOCKING AT ALL <br /> _ CABINET MODULES 36"WIDE OR ,`� L <br /> NE LESS. i LESS.CABINET MODULES 36"WIDE OR <br /> 2"MIN.FILLER AT INSIDE BLIND -- - 2"MIN.FILLER AT INSIDE BLIND Q 3 c LL <br /> CORNER CABINETS-SEE INT.ELEV. <br /> i CORNER CABINETS-SEE INT.ELEV. IT I <br /> FINISH FLOOR PRE-MANUFACTURED BASE PRE-MANUFACTURED BASE y °'¢ <br /> CABINET UNITS-SEE INT.ELEV. CABINET UNITS-SEE INT.ELEV. L3 0 <br /> •DIMENSION IS 46"MAX.A.F.F.AND LOCATED 36"MIN.FROM 4) w-d e <br /> INSIDE CORNERS IN KITCHENS(SIDE REACH OVER COUNTERTOP), FACE OF FINISHED WALL FACE OF FINISHED WALL <br /> 3 C o m w <br /> TYPICAL 24'�.OX 24"BOX L w> - rc <br /> p .. Ns 3 <br /> 14 RECEPTACLE MOUNTING HEIGHTS r6 CABINET SYSTEM PROFILE-TYPE B ��CABINET SYSTEM <br /> w a @�¢ iw <br /> 1 1/2"=1'-0" 1/2"=1'-0" 1/2"=T-0" L o ¢d 3 z <br /> ZI EXTENT OF NON- a w U zo oG <br /> ABSORBENT VERTICAL w z o >y <br /> 1. GRAB BARS SHALL HAVE AN OUTSIDE DIAMETER OF NOT LESS THAN MATERIAL GRAB BAR � a-i u w 3 <br /> 1-114"OR MORE THAN 1-1/2"AND SHALL PROVIDE A CLEARANCE OF NOT REQ'D AT A �g <br /> 1-1/2"BETWEEN THE GRAB BAR AND THE WALL. MIDPOINT OF TUB DWELLING <br /> 2. TOP OF GRAB BARS SHALL BE LOCATED NOT LESS THAN 33"AND NOT 4"MAX. TOP OF GRAB 39"41" UNITS <br /> UI MORE THAN 36"ABOVE THE FLOOR OF THE ADJACENT CLEAR SPACE. BAR NOTE 3 <br /> ` 3. THE STRUCTURAL STRENGTH OF GRAB BARS,TUB AND SHOWER 1= CL <br /> SEATS,FASTENERS AND MOUNTING DEVICES SHALL MEET THE w 2" NOTE 4 NOTE 2 <br /> O TOP OF TOP OF 153/4" 1Y <br /> FOLLOWING REQUIREMENTS. z 12" 24" 24" ao z - z <br /> EO GRAB z GRAB 12 12 f TOP OF G.B. NOTE 1 <br /> U A. BENDING STRESS INDUCED IN A GRAB BAR OR SEAT BA i B R <br /> INDUCED BY THE MAXIMUM BENDING MOMENT FROM THE ga77 3p APPLICATION OF 300 POUNDS SHALL BE LESS THAN THE - w _ CONTROL z EXTERIOR INTERIOR <br /> ILL <br /> ALLOWABLE STRESS FOR THE MATERIAL OF THE GRAB _ > AREA _� _� g DOOR FRAME& <br /> r BAR OR SEAT. m c'i TYPE A Q o Q DOOR AS <br /> B. SHEAR STRESS INDUCED IN A G.B.OR SEAT BY THE ? UNITS M ro n A N B SCHEDULED <br /> APPLICATION OF 300 POUNDS SHALL BE LESS THAN THE 36"MIN. <br /> ALLOWABLE SHEAR STRESS FOR THE MATERIAL OF THE Q 1g^ Q SEE NOTE#4 •15"-17"IN DWELLING UNITS 70P OF SEAT NOTE 3 <br /> y G.B.OR SEAT.IF THE CONNECTION BETWEEN THE G.B.OR NOTES: 12" 24" LOW PROFILE MTL. <br /> E SEAT AND ITS MOUNTING BRACKET OF OTHER SUPPORT P4., IN. MIN. 18"@ TYPE A UNIT THRESHOLD&COMP. <br /> NOTES 1. VANITY CAN OVERLAP REQ'D CLR. <br /> IS CONSIDERED TO BE FULLY RESTRAINED,THEN THE g 15"@ TYPE B UNIT WEATHERSTRIP W. <br /> O DIRECT AND TORSIONAL SHEAR STRESSES SHALL BE 1. TOILET CAN ENCROACH THE REQUIRED CLEAR FLOOR --- ----- FLR.SPACE @DWELLING UNITS SEALANT PROJECT#: 1827 <br /> 0 TOTALED FOR THE COMBINED SHEAR STRESS,WHICH N ONLY.KNEE (OR REMOVABLE <br /> SPACE @TUB IN TYPE B UNITS. 742 <br /> is SHALL NOT EXCEED THE ALLOWABLE SHEAR STRESS. I I � CAB)REQ'D @ TYPE A UNITS.TYPE A � � DRAWN BY: GLEE <br /> 2. ATTYPEAUNITS:A HAND SHOWERWITH A HOSE 59" 4"MAX. <br /> w C. SHEAR FORCE INDUCED IN A FASTENER OR MOUNTING Z UNITS WIOVERLAP REQUIRES MIN.LENGTH THAT CAN BE USED BOTH AS A FIXED 60"X66"CLR.FLR.SPACE. F.F. CHECKED BY: ST <br /> DEVICE FROM THE APPLICATION OF 300 POUNDS SHALL SHOWER HEAD AND AS A HAND SHOWER SHALL BE F.F.BE LESS THAN THE ALLOWABLE LATERAL LOAD OF EITHER PROVIDED.THE HAND SHOWER SHALL HAVE A 2. FLUSH CONTROL SHALL BE NOTE 1O THE FASTENER OR MOUNTING DEVICE OR THE •CLEAR MOUNTED FOR USE FROM THE OPEN <br /> N CONTROL WITH A NONPOSITIVE SHUT-OFF FEATURE. 60"X56"CLR.FLR.SPACE INTERIOR& <br /> SUPPORTING STRUCTURE,WHICHEVER IS THE SMALLER FLOOR SIDE OF THE WATERCLOSETAREA. a DOORS TO ACCESSIBLE SPACES SHALL HAVE AAN ADJUSTABLE HEIGHT SHOWER HEAD MOUNTED ON A L '�`� (48"X56"TYPE B UNIT) ACCESSIBILITY <br /> ALLOWABLE LOAD. VERTICAL BAR SHALL BE INSTALLED SO AS NOT TO _L SPACE (TYPEAUNIT) 18"MAX DOOR THRESHOLD WITH.MAXIMUM HEIGHT OF <br /> U -- 3. REAR GRAB BAR CAN BE 24"IN - 1/2"PER PER ICC/ANSI 117.1 SEC.404.2.4. DETAILS <br /> D. TENSILE FORCE INDUCED IN A FASTENER BY A DIRECT OBSTRUCT THE USE OF GRAB BARS. <br /> TENSION FORCE OF 300 POUNDS PLUS THE MAXIMUM 3. CONTROL AREA RESTRICTION FOR TYPE A UNITS ONLY. DWELLING UNITS WHERE WALL -----J�60"X66"CLR.FLR.SPACE <br /> MOMENT FROM THE APPLICATION OF 300 POUNDS SHALL SPACE DOES NOT ALLOW FOR 36". @ TYPE A UNITS CHANGES IN LEVEL GREATER THAN il4"IN HEIGHT <br /> 4. AT TYPE B UNITS WHERE WATER CLOSET IS DIRECTLY AND NOT MORE THAN 1/2"MAX.IN HEIGHT SHALL BE <br /> BE LESS THAN THE ALLOWABLE WITHDRAWAL LOAD ADJACENT TO BATHTUB,PROVIDE BLOCKING FOR A 24" 12"MIN. 4. IN TYPE B UNITS,WHERE FIXTURES 60" WNANITY OVERLAP BEVELED WITH A SLOPE NOT STEEPER THAN 1:2 q 5 5 0 <br /> BETWEEN THE FASTENER AND THE SUPPORTING REAR GRAB BAR AND A FLIP DOWN GRAB BAR AS '30"X60"TYPE A ARE LOCATED ON EACH SIDE,A PER ICC/ANSI At 17.1 SEC.303.3 <br /> ui SWING-UP GRAB BAR IS PERMITTED <br /> STRUCTURE. SHOWN. 48"X60"TYPE B <br /> ON THE 18"SIDE. <br /> w 13 GRAB BAR REQUIREMENTS ��ACCESSIBLE BATHTUB ��ACCESSIBLE WATER CLOSET ��ACCESSIBLE DOOR THRESHOLD PERMIT SET 10/09/2020 <br /> u= 1'..=1'-0„ 1/4"=T-0" 1/4"=111" 1 112"=V-0" <br />