My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8102 EVERGREEN WAY 2020 EVERETT 4 CORNERS - BLDG A Plans 2025-06-20
>
Address Records
>
EVERGREEN WAY
>
8102
>
EVERETT 4 CORNERS - BLDG A
>
Plans
>
8102 EVERGREEN WAY 2020 EVERETT 4 CORNERS - BLDG A Plans 2025-06-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/20/2025 7:33:04 AM
Creation date
5/9/2025 10:56:40 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
8102
Tenant Name
EVERETT 4 CORNERS - BLDG A
Permit
B2010-048
Year
2020
Notes
FOUR CORNERS APTS - BLDG A-5, OVER 1 MULTIFAMILY RESID BLDG
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
100
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
a FIRE&SOUND ASSEMBLIES GENERAL NOTES <br /> 1. GA FILE IS FROM GYPSUM ASSOCIATION FIRE RESISTANCE '11` <br /> DESIGN MANUAL GA-600-2015 21ST EDITION,WASHINGTON <br /> D.C. CONTRACTOR IS TO PROVIDE(2)COPIES OF THIS <br /> MANUAL ON THE JOB SITE TO COORDINATE FIRE RESISTIVE JOHNSON BRAUND- <br /> a ATTACHMENT W ITH SHEAR CONNECTORS AND SOUND 15200 52nd Ave.South <br /> RATED ASSEMBLIES.CONTRACTOR SHALL REFER TO THE Suite 300 <br /> "GENERAL EXPLANATORY NOTES"FOR ANY ALLOWED Seattle,WA 98188 <br /> DEVIATION FROM THE TESTED ASSEMBLY. Phone 206.766.8300 <br /> 2. THESE DETAILS REPRESENT MINIMUM ARCHITECTURAL —pi—insoabmuad.wm <br /> REQUIREMENTS.IN SOME CASES THE STRUCTURAL ARCHITECTURE <br /> DRAWINGS WILL DETERMINE THE ACTUAL DIMENSIONS AND INTERIOR DESIGN <br /> CONNECTION METHODS,AND IN THOSE CASES WILL <br /> GOVERN.IT IS THE CONTRACTOR'S RESPONSIBILITY TO Greg L.All—, <br /> COORDINATE THE STRUCTURAL DRAWINGS WITH THESE Jeffrey A.Williams, <br /> MINIMUM ARCHITECTURAL ASSEMBLIES. <br /> 3. STC&ACC TESTS ARE FROM GA MANUAL LISTED ABOVE, <br /> OWENS-CORNING WALL&FLOOR ASSEMBLY GUIDE OR <br /> FROM ICBO/ICC REPORTS. <br /> 4. SOUND TRANSMISSION REQUIREMENTS APPLY TO COMMON <br /> INTERIOR WALLS,PARTITIONS AND FLOOR CEILING <br /> ASSEMBLIES BETWEEN ADJACENT DWELLING UNITS OR <br /> BETWEEN DWELLING UNITS AND ADJACENT PUBLIC SPACES <br /> SUCH AS CORRIDORS,STAIRS AND SERVICE AREAS(20151BC <br /> 1207). <br /> IBC SECTION 1207.2 AIR-BORNE SOUND: NOT LESS THAN <br /> STC 50(451F FIELD TESTED).PENETRATIONS OR OPENINGS IN <br /> CONSTRUCTION ASSEMBLIES FOR PIPING,ELECTRICAL <br /> DEVICES,RECESSED CABINETS,BATHTUBS,SOFFITS,OR ass. <br /> HEATING,VENTILATING OR EXHAUST DUCTS SHALL BE REGISTERED <br /> SEALED,LINED,INSULATED OR OTHERWISE TREATED TO ARCHITECT <br /> MAINTAIN RATINGS.THIS REQUIREMENT SHALL NOT APPLY <br /> TO DWELLING UNIT ENTRY DOORS,HOWEVER SUCH DOORS <br /> SHALL BE TIGHT FITTING TO FRAME AND SILL. <br /> IBC SECTION 1207.3 STRUCTURE-BORNE SOUND:NOT LESS r eFaev>nrxors wnJ.1Am <br /> STATE OF WASHINGTON <br /> THAN IIC 50(451F FIELD TESTED). <br /> GA FILE NO.WP 7054.4 PROPRIETARY' 2 HOUR 50 to 54 STC 5. FLOOR/CEILING ASSEMBLY:STC 50/IIC 50 MIN. sTAmv <br /> DEMISING WALL:STC 50 MIN. <br /> GYPSUM PANEL PRODUCTS,STEEL C-H,C-T,OR I STUDS FIRE SOUND CORRIDOR WALLS:STC 50 MIN. <br /> 6. WHERE SOUND RATED ASSEMBLIES INCLUDE THE USE OF k <br /> One 11111'x24"pW6elery type Xgyp.—panelsmserled between 211e Anon a no celkng "RESILIENT CHANNELS",DIETRICH RC-1 DELUXE CHANNELS <br /> J runners with T section of 214 steal C-H,C-T,or I studs b~.-panel, IT <br /> J SHALL BE USED. e <br /> OPPOSITE SIDE.Bata layer'W pmpnetary type X g l Im wall apphm. at rgm -�- 7. SOUND RATED ASSEMBLIES-SOUND CONTROL: <br /> angles to studs with 1'Type S drywall screws 24'a c.and 6"from noon and milmg - -- SYSTEMS SHALL BE AIR-TIGHT.ITEMS THAT PENETRATE o <br /> rttnners Face layer Ili'proprietary type X gyW..walfin-ld applied pamlled to studs THE GYPSUM BOARD SHALL NOT BE LOCATED BACK TO <br /> with Isle'Type S drywall screws 12"o.c.and 3"from floor and ceding runners-Joints BACK OR IN THE SAME STUD CAVITY.ANY OPENINGS FOR <br /> off"24'trom base layer pints Thicknesa: 31W FIXTURES OR PIPES SHALL BE CUT TO THE PROPER SIZE R <br /> AppAND SEALED.THE ENTIRE PERIMETER OF A SOUND a <br /> Sound testeo with 1 Vi glass goer Insulation InclOn lit In stud spaoa(NLB) F,,e T Weghl: 9 psi INSULATING SYSTEM SHALL BE MADE AIR TIGHT TO rn o <br /> Fire Test ITS.8.30.01, <br /> PROPRIETARY GYPSUM PANEL PRODUCTS ITS Deaign GPNYA 12M1 PREVENT SOUND FLANKING.FLEXIBLE SEALANT OR AN <br /> Georgia Pacific Gypsum LLC - 1fi ToughRockli,Fireguard OD Sound Test. RAIL TL09.060.12.8.09) ACOUSTICAL GASKET SHALL BE USED TO SEAL BETWEEN <br /> Gypsum Board THE STC RATED SYSTEM AND ALL DISSIMILAR SURFACES <br /> I'DamGlamE)Shaft iner AND ALSO BETWEEN THE SYSTEM AND SIMILAR SURFACES <br /> WHERE PERIMETER RELIEF IS REQUIRED.TAPING GYPSUM <br /> BOARD WALL AND WALL-CEILING INTERSECTIONS PROVIDES <br /> AN ADEQUATE AIR SEAL AT THESE LOCATIONS(ASTM E 497, <br /> (2)LAVERS 5/8"TYPE X GWB GA MANUAL SECTION III). c <br /> 8. PROVIDE FIREBLOCKING IN ACCORDANCE WITH 20151BC <br /> SECTION 718.2 AS NOTED ON SHEET A040 `u <br /> .... . ... .. .... ... . .. .... . . . ...... .." 9. PROVIDE PROTECTION FOR THROUGH PENETRATIONS AND oa <br /> 2-1/2"CH STUD,SEE MEMBRANE PENETRATIONS OF HORIZONTAL ASSEMBLIES <br /> EXPLANATORY NOTE B. AND FIRE RATED WALL ASSEMBLIES IN ACCORDANCE WITH <br /> 2015 IBC SECTION 714 AS NOTED ON SHEET A040. E <br /> SHAFT SIDE 10. JOINTS INSTALLED IN OR BETWEEN FIRE RESISTIVE RATED 8 <br /> WALLS,FLOORS OR FLOOR/CEILING ASSEMBLIES AND <br /> 1"PROPRIETARY TYPE W ROOFS OR ROOF/CEILING ASSEMBLIES SHALL BE <br /> GYPSUM PANELS PROTECTED BY AN APPROVED FIRE-RESISTANT JOINT a <br /> SYSTEM IN ACCORDANCE WITH 20151BC SECTION 715 AS 3 <br /> NOTED ON SHEET A040 0 <br /> 2-HOUR RATED NON-COMBUSTIBLE SHAFT WALL SHAFT"CLOSURE"WALL 11. CONTINUITY OF FIRE RATED WALLS: <br /> ❑ A.FIRE BARRIERS(IBC SECTION 707.5)AND SHAFT m <br /> 4J2 GA FILE:WP 7054.4 REQUIRED STC: ENCLOSURES(IBC SECTION 713.5):SHALL EXTEND FROM <br /> TYPE:FIRE BARRIER-TYPE IA CONSTRUCTION NONE THE TOP OF THE FLOOR/CEILING BELOW TO THE <br /> LOCATION:LEVEL 2-6 SHAFT ENCLOSURE WALL UNDERSIDE OF THE FLOOR.ROOF SHEATHING,SLAB OR <br /> DECK ABOVEAND SECURELY ATTACHED THERETO.AND <br /> SHALL BE CONTINUOUS THROUGH CONCEALED SPACES. 3 <br /> B.SMOKE BARRIER(IBC SECTION 709.4):SHALL EXTEND <br /> FROM THE TOP OF THE FOUNDATION OR FLOOR/CEILING <br /> WALLBOARD TO BE ASSEMBLY BELOW TO THE UNDERSIDE OF THE FLOOR. o <br /> APPLIED WITH NO ROOF SHEATHING,SLAB OR DECK ABOVE OR TO THE <br /> HORIZONTAL JOINTS FIRE-RESISTANCE RATED FLOOR/CEILING OR ROOF <br /> (2)1/2"TYPE"X" (4)1/2"TYPE"X" CEILING ABOVE, zo <br /> TAPE AND TREAT C.SMOKE PARTITIONS(IBC SECTION 710.4):SHALL FORM <br /> GYPSUM WALLBOARD�... EXPOSED CORNERS GYPSUM WALLBOARD AN EFFECTIVE MEMBRANE CONTINUOUS FROM OUTSIDE <br /> STAGGER CORNERS OF WALL TO OUTSIDE WALL AND FROM THE TOP OF THE <br /> w <br /> HISS COLUMN PER EACH LAYER HSS COLUMN PER FOUNDATION OR FLOOR/CEILING ASSEMBLY BELOW TO y <br /> THE UNDERSIDE F THE FLOOR OR ROOF SHEATHING <br /> O , w <br /> STRUCTURAL— STRUCTURAL DECK OR SLAB ABOVE,INCLUDING CONTINUITY THROUGH <br /> SECURE GWB LAYER CONCEALED SPACES. 6 <br /> BELOW OUTER LAVER WITH 12. SEE"ENERGY CODE COMPLIANCE"NOTES ON SHEET CS01 <br /> DOUBLED.049"STEEL WIRE FOR INSULATION REQUIREMENTS. E <br /> TIES @ 15"O.C. �€ <br /> OUTER LAYERS SECURED WITH 13. ALL EXTERIOR GYPSUM SHEATHING BOARD(5/8"TYPE X) <br /> CONSTRUCTION ADHESIVE APPROVED SHALL BE DENS-GLASS GOLD OR EQUAL. C <br /> UNDER ASTM El 19 OR UL 263 i <br /> 14. THE TERMS"GYPSUM WALLBOARD"AND"GWB"ARE <br /> INTERCHANGEABLE. Q 3 c LL <br /> 15. WATER-RESISTANT GYPSUM WALLBOARD SHALL BE USED acr $ <br /> 1-and 2-HOUR RATED COLUMN PROTECTION AT ALL"WET LOCATIONS",I.E.@ BATHTUBS. L ¢ <br /> 1-1HR OF9 GA MANUAL GENERAL EXPLANATORY NOTES 3 <br /> IBC:TABLE 7211.10)1-7.1 WITH NOTES c AND d REQUIRED STC:NONE ry d a <br /> () A. PER GA MANUAL GENERAL EXPLANATORY NOTE#11:"WHEN C <br /> 2-HR TYPE:I-A OR V-A CONSTRUCTION REQUIRED IIC:NONE w rc <br /> OF2 NOT SPECIFIED AS A COMPONENT OF A FIRE TESTED WALL L a <br /> LOCATION:SEE PLANS OR PARTITION SYSTEM,MINERAL FIBER,GLASS FIBER OR 0 .. a U rn go �3 <br /> CELLULOSE FIBER INSULATION OF A THICKNESS NOT / N U in 3w <br /> EXCEEDING THAT OF THE STUD DEPTH SHALL BE V w o. <br /> x IBC TABLE 121.1(2114-1.5-2 HOUR RATED BEARING WALL lY <br /> G PERMITTED TO BE ADDED WITHIN THE STUD CAVITY." L ❑ ¢u 3? <br /> WOOD STUDS:MINIMUM 2X4 NOMINAL SPACED 16"O.C. O a E w <br /> ml 6D COOLER OR WALLBOARD NAILS AT 9"ON CENTER.FACE LAVER APPLIED VERTICALLY OR HORIZONTALLY AND NAILED BGYPSUM BOARD:(2)LAYERS 5/8"THICK TYPE X,4'WIDE EACH SIDE.BASE LAYERS APPLIED VERTICALLY AND NAILED WITH ¢ w U a o' <br /> zI . PER GA MANUAL GENERAL EXPLANATORY NOTE#16 =' <br /> 0 o <br /> wa <br /> WITH 8D COOLER OR WALLBOARD NAILS AT 7"ON CENTER.FOR NAIL-ADHESITVE APPLICATION,BASE LAYERS ARE NAILED "GREATER STUD SIZES(DEPTHS)SHALL BE PERMITTED TO � m O w to <br /> 6"ON CENTER.FACE LAYERS APPLIED WITH COATING OF APPROVED WALLBOARD ADHESIVE AND NAILED 12"ON CENTER. BE USED IN METAL OR WOOD-STUD SYSTEMS.METAL <br /> JOINT TAPE&COMPOUND:FACE LAYER JOINTS TO BE COVERED WITH PAPER TAPE AND JOINT COMPOUND,FASTENER STUDS OF HEAVIER GAGE THAN THOSE TESTED SHALL BE <br /> G HEADS COVERED WITH JOINT COMPOUND.LEVEL 1 FINISH ONLYIN CONCEALED AREAS PERMITTED.THE ASSIGNED RATING OF ANY LOAD BEARING <br /> NI SYSTEM SHALL ALSO APPLY TO THE SAME SYSTEM WHEN <br /> N 1/2 OF WALL 7D USED AS A NON-LOAD BEARING SYSTEM.INDICATED STUD <br /> E GWB FINISHED PER ASSEMBLY 7D SPACING ARE MAXIMUMS." <br /> INSULATION PER ASSEMBLY 7D <br /> U UNIT STUDS OFFSET 8"FROM ASW <br /> SHEATHING PER STRUCTURAL C. PER GA MANUAL GENERAL EXPLANATORY NOTE#17 <br /> "SPECIFIED FLOOR-CEILING AND ROOF-CEILING FRAMING <br /> LL 16" SIZES OR TRUSS DIMENSIONS ARE MINIMUMS.GREATER <br /> r JOIST OR TRUSS SIZES(DEPTHS)SHALL BE PERMITTED TO <br /> N BE USED IN METAL-OR WOOD-FRAMED SYSTEMS. <br /> (2)5/8"TYPE X GWB INDICATED JOIST AND TRUSS SPACING ARE MAXIMUMS." <br /> y <br /> WN <br /> 3 DESIGN LIMITATIONS,THE DISTANCE BETWEEN PARALLEL <br /> cp o rn ROWS OF STUDS,SUCH AS IN A CHASE WALL,SHALL BE <br /> O w ¢ PERMITTED TO BE INCREASED BEYOND THAT TESTED. PROJECT#: 1827 <br /> 0 2X4 STUD .... :...... .. <br /> WHEN STUD CAVITIES IN WALLS CONSTRUCTED OF x .. . ... .. ..... . . <br /> N - PARALLEL ROWS OF STEEL STUDS EXCEED 9-1/2"AND DRAWN BY: Author <br /> g (2)5/8"TYPE X GWB CROSS FAB BRACICT D FING IROM 3T EL STUDS.UIRED THE CROSS BRACING SHALL CHECKED BY: Checker <br /> N <br /> y <br /> AT CORRIDOR L 8" L 8" E. PER GA MANUAL GENERAL EXPLANATORY NOTE#22 VERTICAL ASSEMBLIES <br /> U AIR GAP "ADDITIONAL LAYERS OF TYPE X OR REGULAR GYPSUM <br /> 1/2 OF WALL 7D PANELS SHALL BE PERMITTED TO BE ADDED TO ANY <br /> SYSTEM." <br /> AT DEMISING WALLS F. PER GARI MANUAL GENERAL EXPLANATORY NOTE#24"EACH A 41 <br /> 2HR-RATED WOOD AREA SEPARATION WALL SEPARATION FIRE WALL PROPRIETARY SYSTEM LISTS SPECIFIC PRODUCTS THAT <br /> ARE ACCEPTABLE FOR USE IN THE SPECIFIC SYSTEM IN <br /> ¢ 7K REQUIRED STC:50 FyOR INFORMATION HICH THEY ARE LISTED. <br /> ON ADDITIONAL PROPRIETARY MANUFACTURER PERMIT SET 10/09/2020 <br /> z IBC:TABLE 721.1(2)14-1.5 <br /> i TYPE:FIRE WALL-TYPE V-A CONSTRUCTION <br /> LL LOCATION:AREA SEPARATION WALL-BUILDING B ONLY PRODUCTS THAT ARE SUITABLE FOR USE IN SPECIFIC <br /> PROPRIETARY SYSTEMS." <br />
The URL can be used to link to this page
Your browser does not support the video tag.