My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8102 EVERGREEN WAY 2020 EVERETT 4 CORNERS - BLDG A Plans 2025-06-20
>
Address Records
>
EVERGREEN WAY
>
8102
>
EVERETT 4 CORNERS - BLDG A
>
Plans
>
8102 EVERGREEN WAY 2020 EVERETT 4 CORNERS - BLDG A Plans 2025-06-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/20/2025 7:33:04 AM
Creation date
5/9/2025 10:56:40 AM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
8102
Tenant Name
EVERETT 4 CORNERS - BLDG A
Permit
B2010-048
Year
2020
Notes
FOUR CORNERS APTS - BLDG A-5, OVER 1 MULTIFAMILY RESID BLDG
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
100
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SHEET NOTES <br /> 1. LEVELS 2-6 TYPE VA CONSTRUCTION <br /> R2 OCCUPANCIES <br /> OHNSON BRAUND- <br /> a <br /> 2. ALL LEVELS FULLY SPRINKLERED PER 15200 52nd Ave.South <br /> IBC SECTION 903.3.1.1(NFPA 13). Suite 300 <br /> REFER TO SHEETS CS03 FOR FIRE Seattle,WA 98188 <br /> 3. ASSEMBLY KEY PLAN W/WALL TYPE Phone 206.766.8300 <br /> TAGS&LOCATIONS.REFER TO vmvjohnsonhmund- <br /> SHEET SERIES A040 FOR ASSEMBLY ARCHITECTURE <br /> DETAILS. INTERIOR DESIGN <br /> 4. SEE ENLARGED UNIT PLANS FOR ALL Greg L.Allme, <br /> INTERIOR DIMENSIONS,WINDOW AND Jeffrey A.Williams, <br /> DOOR CALL-OUTS,AND RATED WALL <br /> TAGS <br /> 5 EXIT STAIR ENCLOSURES IN TYPE 1A <br /> CONSTRUCTION SHALL BE 3-HOUR <br /> RATED <br /> 6 ALL VERTICAL SHAFTS SHALL BE 2- <br /> HOUR RATED PER IBC SECTION 713.4. <br /> 7. ODOOR TYPE-SEE SCHEDULE <br /> SHEET A100 <br /> 8. REFER TO SHEET SERIES A100 FOR asss <br /> UNIT PLAN DOOR&WINDOW REGISTERED <br /> SCHEDULE. ARCHITECT <br /> 9. REFER TO SHEETS At 10,At 20, <br /> At 30,A140,A150&A151 FOR eTATl - wGTJENLARGED UNIT PLANS. wnsHlucTON <br /> 10. REFER TO ACCESSIBILITY NOTES -P <br /> ON SHEET CS00 <br /> k <br /> 11. PROVIDE MECHANICALLY s <br /> FASTENED INSULATION AT ALL e t <br /> CEILINGS BETWEEN CONDITIONED <br /> AND UNCONDITIONED SPACE, o' <br /> REFER TO SHEET A040 FOR <br /> REQUIRED R-VALUES. <br /> ,E <br /> �Ha <br /> 12. CORRIDOR VENTILATION CONCEPT <br /> SHOWN,REFER TO DESIGN/BUILD <br /> MECHANICAL PLANS. <br /> A.a A311 A.B 13. F.E.C. CAB NETED/FIRE EXTINGUISHER <br /> 5 3 SEE DETAIL: <br /> 1 A412 A051 <br /> 0 <br /> 48'-51/2" 21/4" 9'-101/2" 21/4" 45'-11" 1" <br /> 14 F.E. SURFACE MOUNTED FIRE <br /> A412 - <br /> EXTINGUISHER CABINET <br /> 10'-6" 12'-6" 10'-01/4" 12'-10" 10'-8" 12'-9" &-8112"]L5._10112'-,rl'- V-11" LOCATE PER IBC TABLE 906.3 y <br /> (1)75 FT.MAX.SEPARATION- p <br /> a PARKING GARAGE LEVEL ONLY <br /> SEE DETAIL 3/A051 FOR <br /> A412 I MOUNTING/INSTALLATION <br /> 7A 7A 7A HEIGHT <br /> 4 - 15. EXIT SIGN PER IBC SECTION 1013. <br /> �``oy I <br /> m <br /> 16. REFER TO DESIGN/BUILD p <br /> ELECTRICAL PLANS. <br /> JDN <br /> m <br /> 17. REFER TO SHEET A051 FOR <br /> 7p PENETRATION REQUIREMENTS IN <br /> 2 II 7D7D ' FIRE RATED CONSTRUCTION. <br /> A410 7A II t 18. REFERENCE BUILDING ENVELOPE <br /> DRAWINGS FOR ALL WATERPROOFING. p <br /> _ - - INDICATES TYPE A ACCESSIBLE UNIT. o <br /> ALL REMINING UNITS SHALL MEET TYPE <br /> 66 PER BC SECTION 1107.6.21REMENTSOOUNIT 4.1 CORRIDOR SH FT UNIT 3.1 <br /> 622 I ZO <br /> 620 20 UNIT DEMISING WALLS ARE 1 HOUR 1. <br /> SHEET A140 SHEET A130 - RATED PER IBC SECTION 708 WI <br /> a MINIMUM STC 50.SEE SHEETS A040&A041 (A <br /> ® pII 0 III c - <br /> 181 0 21.® INDICATES TYPE'A'UNIT <br /> 01 <br /> O STO GE 7B STORAG aw <br /> 1'-6- 13'-6" O 1 7J 22. AT DOORS INTO ELECTRICAL CONTROL E <br /> O - - - 5-603 - 0 O O S PANEL ROOMS,SIGNAGE SHALL BE <br /> A.3 PROVIDED ON THE DOOR STATING <br /> 2 `v STORAGE 7C _ _ _ _ _ _ CORRIDOR 'ELECTRICAL ROOM' 90 <br /> A411 A31 2 - 5-605 21 7C 600 23. AT DOORS INTO FIRE PROTECTION I �. LL <br /> F.E.C. F.E.C. EQUIPMENT ROOMS CONTAINING Q 3 0 <br /> A.4� Y1 2 2 SPRINKLER RISERS,FACP,OR OTHER c <br /> III � SUPPRESION CONTROL ELEMENTS, (� a°'i O1 <br /> o S-604 76 4� II oO APPROVED SIGNAGE SHALL BE <br /> o o ® 24 FCO SEDEDAN CTION ON 509.1 READILY VISIBLE PER r w w g rcj <br /> IL ® ° TTWO-WAY COMMUNICATION L N z <br /> 3 1 D W� SYSTEM PER IBC SECTION 1009.8 C N U N 3� <br /> w ad`a zz <br /> D ❑ a E w e' 3 <br /> Z o <br /> 0 <br /> ZI _ III --- m �� <br /> _-_- UNIT 4.1 --- NIT 3.1 UNIT 1.1 LL <br /> ---- 623 --- 621 619 <br /> I 7A <br /> N <br /> II SHEETA140 S EET At 30 SHEET At 10 <br /> E2 <br /> E II 7D 7D 7D <br /> O <br /> LL <br /> U I <br /> N <br /> N �o <br /> 7A o�N 7A <br /> Lo <br /> E 2 1 <br /> 10'-6' 12'-6" 10'-0114" 12'-10' 9'-11" 10'-8' I12'-V A31 -211, 10'-0" 3'-21/" PROJECT#: 1827 <br /> 40'-11' 1" 25'-1t" " KEY PLAN <br /> DRAWN BY: AT <br /> 4) <br /> CHECKED BY: ST <br /> j BLDG A-FLOOR 6 <br /> Ci <br /> WEST <br /> w A215A <br /> BUILDING A <br /> Z ��� 6LDG A-LEVEL 6 WEST <br /> I\I PERMIT SET 10/09/2020 <br /> w <br /> LL 1/8"=V-0" <br />
The URL can be used to link to this page
Your browser does not support the video tag.