My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3620 W MUKILTEO BLVD D HARBORS EDGE TOWNHOMES 2025-08-13
>
Address Records
>
W MUKILTEO BLVD
>
3620
>
HARBORS EDGE TOWNHOMES
>
3620 W MUKILTEO BLVD D HARBORS EDGE TOWNHOMES 2025-08-13
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/13/2025 11:06:55 AM
Creation date
5/9/2025 2:56:42 PM
Metadata
Fields
Template:
Address Document
Street Name
W MUKILTEO BLVD
Street Number
3620
Unit
D
Tenant Name
HARBORS EDGE TOWNHOMES
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
69
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Viking Plastics <br />CPVC Pipe Product Specifications <br />BlazeMaster" CPVC Pipe <br />Corrosion resistant CPVC fire sprinkler pipe, when installed in strict accordance with the manufacturer's design and instal- <br />lation instructions, is UL and c-UL Listed by Underwriters Laboratories for use in the following: <br />• Meets NFPA 13R and 13D standards for residential occupancies as well as NFPA 13 standards for light hazard occupancies. <br />• Residential occupancies up to and including four stories in height as defined by NFPA 13R. <br />• Residential occupancies as defined in the Standard for Sprinkler Systems in One and Two Family Dwellings, NFPA 13D. <br />• Installation of private fire service mains and their appurtenances, NFPA 24. <br />CPVC fire sprinkler pipe from Viking Plastics shall be employed in wet pipe systems only and are not listed for outdoor use. <br />CPVC pipe must never be used in a system using compressed air or other gases. <br />CPVC pipe from Viking Plastics also carries the follow- <br />ing enhanced listings and approvals: <br />• According to UL Listing <br />• Can be flush at return air plenums <br />• Exposed system risers NFPA 13D, 13R <br />• Exposed basement NFPA 13D (solid wood joist) <br />• Extended coverage (exposed) <br />• 20' spacing on pendent in lieu of 15' <br />• 18' spacing on sidewall in lieu of 14' <br />• Use with combustible concealed sprinklers <br />• Tyco attic sprinkler head (to protect the floor below) <br />• Tyco attic sprinkler head with wet system piping <br />(feed main and ridge installation) <br />New and enhanced listings and approvals are being pursued. Always <br />check with the appropriate Listing and Approval agency for details on <br />current listing parameters. <br />CPVC pipe meets all applicable standards for pressure rated applica- <br />tion as required in ANSI -NSF Standard 14 and complies with ANSI -NSF <br />Standard 61 for health effects and are marked with the NSF-pw end use <br />marking. <br />All CPVC fire sprinkler pipe shall be Listed by Underwriters Laboratories <br />for wet pipe systems, and shall carry a rated working pressure of 175 psi <br />@ 150°F (12 bar @ 65.5°C). *The FM Approval is limited to use in wet <br />pipe fire protection sprinkler systems for light hazard occupancies in both <br />concealed and exposed applications with certain restrictions. <br />Piping must always be installed in strict accordance to the manufacturer's <br />DESIGN AND INSTALLATION GUIDE, including product storage and <br />handling, joining methods, supporting and bracing, expansion and con- <br />traction allowance and testing, etc. National Fire Protection Association <br />(NFPA) Standards 13, 13D, and 13R must be referenced for design and <br />installation requirements in conjunction with the installation instructions. <br />• Exposed sidewall sprinkler listing for exposed pipe & fittings <br />• 24' extended coverage sidewall sprinkler, 12" drop, 155T <br />sprinkler head <br />• 18' extended coverage sidewall sprinkler, 12" drop, 165T <br />sprinkler head <br />• 16' extended coverage sidewall sprinkler, 12" drop, 175T <br />sprinkler head <br />• 14' standard coverage sidewall sprinkler, 12" drop, 200T <br />sprinkler head <br />Factory Mutual Approved* <br />• Factory Mutual Approval exposed <br />• Factory Mutual Approval above drop -in ceilings <br />• Factory Mutual Approval exposed w/Soffi-Steel soffiting <br />covering system <br />All CPVC fire sprinkler pipe from Viking Plastics is manufactured in the <br />USA. All CPVC pipe shall be packaged immediately after its manufacture <br />to prevent damage and shall be stored indoors after production, at the <br />manufacturing site, until shipped from the factory. The pipe shall bear the <br />logo of the listing agencies, and shall carry the National Sanitation Foun- <br />dation (NSF) seal of approval for potable water applications. <br />CPVC products are intended for use in areas where the maximum ambi- <br />ent temperature does not exceed 150°F (65.5°C). If the ambient tempera- <br />ture is expected to exceed this limitation, refer to the manufacturer's DE- <br />SIGN AND INSTALLATION GUIDE for additional information on methods <br />to reduce the pipe exposure temperatures. CPVC pipe is not intended to <br />be installed in outdoor applications. CPVC pipe is intended to be used in <br />wet pipe systems only and have not been investigated for use in dry pipe <br />systems. Special installation and design criteria relative to pipe hanger <br />spacings, piping and sprinkler restraint, sprinkler temperature rating, <br />piping locations, testing procedures and friction loss characteristics are <br />specified in the manufacturer's installation instructions provided with the <br />pipe. The manufacturer's installation instructions should be reviewed and <br />the Authority Having Jurisdiction consulted before installation. <br />Trusted above all TM NAMM4 ® <br />
The URL can be used to link to this page
Your browser does not support the video tag.