Page 4 of 5 <br />'R= FREEDOM° RESIDENTIAL <br />CONCEALED PENDENT <br />SPRINKLER VK494 (K4.9) <br />The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 <br />Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com <br />Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com <br />DESIGN CRITERIA <br />(Also refer to the Approval Chart on page 3.) <br />UL Listing Reguirements (C-UL-US-EU): <br />When using Viking Residential Concealed Pendent Sprinkler VK494 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of cover- <br />age and minimum water supply requirements shown in the Approval Chart. <br />For systems designed to NFPA 13: The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers. The minimum <br />required discharge from each of the four sprinklers is to be the greater of the following: <br />• The flow rates given in the Approval Chart for NFPA 13D and NFPA 13R applications for each listed area of coverage, or <br />• Calculated based on a minimum discharge of 0.1 gpm/sq. ft. over the "design area" in accordance with sections 8.5.2.1 or 8.6.2.1.2 of NFPA 13. <br />• Minimum distance between residential sprinklers: 8 ft. (2.4 m). <br />NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. <br />IMPORTANT. Always refer to Bulletin Form No. F 080415 - Best Practices for Residential Sprinkler Handling and Installation. <br />Also refer to Form No. F 080614 for general care, installation, and maintenance information. Viking sprinklers are to be in- <br />stalled in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA and any other similar <br />Authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards, whenever <br />applicable. Final approval and acceptance of all residential sprinkler installations must be obtained from the Authorities <br />Having Jurisdiction. <br />Sprinkler and Adapter Assembly <br />• Protective cap removed <br />• Use wrench 14047W/B** <br />Sprinkler Wrench <br />Part No. 14047W/B** <br />Step 1: <br />Carefully slide the <br />wrench sideways around <br />the deflector and pins <br />NEVER install the sprinkler by applying the installation <br />wrench across the frame arms. DO NOT overtighten. <br />Use only the designated sprinkler wrenches, Viking <br />Part Numbers 14047W/B** or 14031**. A leak tight seal <br />should be achieved by turning the sprinkler clockwise <br />1 to 1-1/2 turns beyond finger tight. <br />2-1/4" (57 mm) <br />neter opening <br />aired in the <br />ing. <br />Step 2: 1 1 <br />Carefully press the wrench upward and <br />turn slightly to ensure engagement with <br />the sprinkler wrench flats. <br />Sprinkler <br />wrench flat <br />Figure 1: Sprinkler Installation and Proper Wrench Usage <br />ink A 1/2" ratchet is required (Not available from Viking) <br />Sprinkler <br />frame arms <br />Form No. F_012116 17.04.20 Rev 17.2 <br />