My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9536 HOLLY DR 2025-07-10
>
Address Records
>
HOLLY DR
>
9536
>
9536 HOLLY DR 2025-07-10
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/10/2025 2:59:45 PM
Creation date
5/23/2025 3:17:56 PM
Metadata
Fields
Template:
Address Document
Street Name
HOLLY DR
Street Number
9536
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
67
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WEST ..i r...... <br /> COAST j; j ........ ' l 9540 Semiahmoo Parkway (425)347-8998 <br /> STRUCTURAL' #137 wcse.net <br /> ENGINEERING,INC. Blaine,WA 98230 <br /> Two Story Shear Wall Design <br /> Shear Wall Grid Location: Grid Line : 4 <br /> Misc. Info: <br /> H upper Overturning Moment (OTM) <br /> OTM = 12.1 k-ft <br /> I I <br /> 2w;. . Resisting Moment(RM) Aspect Ratio Check(2w/h)= 1.33 <br /> ............1 a . m..._.,-...�. H tote W Above = 0.2 kips <br /> W Middle= 0.1 kips <br /> W Wall = 0.5 kips <br /> H lower $ <br /> RM = 2.3 k-ft <br /> Uplift Force @ end of Shear Wall (T) : <br /> = 1.8 kips <br /> T C <br /> Wind or Seismic Critical : W Shear Wall Base Shear(Vb) : 178 plf <br /> V t : 1/2(3.03)/16 = 0.095 klf Internal/External( I/E) : E <br /> V m : 1/2(2.65)/16 = 0.083 klf Nailing Designation : SW2 <br /> H upper= 9.0 ft H lower= 8.0 ft H total= 17.0 ft <br /> L = 5.3 ft Holdown Force(T) : 1.8 kips <br /> Trib. Length Upper(A) : 4 ft Lower( M) : 4 ft Holdown Designation : <br /> Dead Load Above(w above) : 15 psf Lower(w lower) : 10 psf <br /> Reliability- Redundancy Factor: <br /> Seismic Base Shear: <br /> Roof Diaphragm: 3.74 kips 2nd Floor Walls: 3.74 kips 66% <br /> 2nd Floor Diaph: 1.93 kips 1st Floor Walls: 5.67 kips 100% <br /> Note: Seismic force-resisting system shall consist of at least two bays of seismic force resisting <br /> perimeter framing on each side of the structure in each orthogonal direction at each story resisting <br /> more than 35 percent of the base shear. The number of bays for a shear wall shall be calculated <br /> as the length of shear wall divided by the story height or two times the length of shear wall divided <br /> by the story height for light-framed construction. <br /> Shear Wall Bays in X- Direction Shear Wall Bays in Y - Direction <br /> 2nd Floor Side 1: 5.75 Side 2: 4.00 Side 1: 6.75 Side 2: 8.50 <br /> 1st Floor Side 1: 8.00 Side 2: 4.00 Side 1: 8.00 Side 2: 8.00 <br /> No increase in Seismic Force <br /> Project: W4861 Sheet No: 17 9/13/2023 <br />
The URL can be used to link to this page
Your browser does not support the video tag.