WEST <br /> I_ <br /> COAST I �` <br /> -.. Il 9540 Semiahmoo Parkway (425)347-8998 <br /> STRUCTURAL r , t #137 wcse.net <br /> E NGINEERING,INC. Blaine,WA 98230 <br /> Two Story Shear Wall Design <br /> t 1 Shear Wall Grid Location: Grid Line : 4 <br /> Misc. Info: <br /> w <br /> Overturning Moment (OTM) <br /> H upper OTM = 12.1 k-ft <br /> vm Resisting Moment(RM) Aspect Ratio Check(2w/h)= 1.33 <br /> }-------- - H total W Above = 0.2 kips <br /> W Middle= 0.1 kips <br /> W Wall = 0.5 kips <br /> w,mm,a. <br /> H lower • RM = 2.3 k-ft <br /> Uplift Force @ end of Shear Wall (T) : <br /> t.. .- . _. I T = 1.8 kips <br /> T <br /> C <br /> Wind or Seismic Critical : W Shear Wall Base Shear(Vb) : 178 plf <br /> V t : 1/2(3.03)/16 = 0.095 klf Internal/External ( I/E) : E <br /> V m : 1/2(2.65)/16 = 0.083 klf Nailing Designation : SW2 <br /> H upper= 9.0 ft H lower= 8.0 ft H total = 17.0 ft <br /> L = 5.3 ft Holdown Force(T) : 1.8 kips <br /> Trib. Length Upper(A) : 4 ft Lower( M) : 4 ft Holdown Designation : <br /> Dead Load Above(w above) : 15 psf Lower(w lower) : 10 psf <br /> Reliability - Redundancy Factor: <br /> Seismic Base Shear: <br /> Roof Diaphragm: 3.74 kips 2nd Floor Walls: 3.74 kips 66% <br /> 2nd Floor Diaph: 1.93 kips 1st Floor Walls: 5.67 kips 100% <br /> Note: Seismic force-resisting system shall consist of at least two bays of seismic force resisting <br /> perimeter framing on each side of the structure in each orthogonal direction at each story resisting <br /> more than 35 percent of the base shear. The number of bays for a shear wall shall be calculated <br /> as the length of shear wall divided by the story height or two times the length of shear wall divided <br /> by the story height for light-framed construction. <br /> Shear Wall Bays in X- Direction Shear Wall Bays in Y - Direction <br /> 2nd Floor Side 1: 5.75 Side 2: 4.00 Side 1: 6.75 Side 2: 8.50 <br /> 1st Floor Side 1: 8.00 Side 2: 4.00 Side 1: 8.00 Side 2: 8.00 <br /> No increase in Seismic Force <br /> Project: W4861 Sheet No: 17 9/13/2023 <br />