Permit#: <br /> Site Address: 3710WOMukilteo Blvd Unit A �� �� �� HARBOR'S EDGE UNIT 6 NFPA z M <br /> Applicant: Moore Fire Protection -. - : r <br /> Application Date:04/02/2024 13 D <br /> Description: New residential Flow-through system 1LL <br /> SITE SPECIFICATIONS Z <br /> Rtownhouse. Q O <br /> Review Date: 04/03/2024 AHI: City of Everett OWNER/LESSEE: <br /> A RELATED PERMIT: N/A Sage Homes Northwest <br /> rwerrr OCCUPANCY TYPE: Residential Everett, <br /> Ave SE,Suite 118 Q J <br /> EVERETT WEST MUKILTEO BLVD. coNsr.TYPE: v-e 1-1 <br /> Everett Fire Dept.Permit Review +00 98+00 99+00 N 76U+OOB017'08"E 1016.80 100+00 STORIES: 3 (425)609-8074 <br /> i PF PARCEL: 00433600004700 <br /> Status:Approved <br /> Reviewed By:KBrown Submittal for GENERAL DESCRIPTION: <br /> 04/03/2024 2:56:50 Unit 6 Only New single family attached townhome.The typical and mirrored plans are both shown for <br /> PM reference.This submittal is for one plan-type only. <br /> c ,_ ______________________ ____ ___ ___ ______________________________________________________________________________________________.____________________________________________________________________________ __ _____________ _____________ __________ <br /> ------------------------- LEGAL DESCRIPTION: <br /> EDGEWATER BLK 000 D-00-LOT 47 <br /> FIRE FLOW <br /> 340." <br /> HYD STATIC(PSI): 117 BOR STATIC(PSI): 104 <br /> RESIDUAL(PSI): 53 HYD ELEVATION(FT): 132.13 <br /> APPROVED GRADE = GRADE= P FLOW(GPM): 1,331 MODEL REPORT DATE:02/03/23 <br /> PUBLIC WORKS DEPARTMENT <br /> BY:THerman GRADE=152.5 GRADE=151.6 SYSTEM SPECIFICATIONS <br /> DATE:04/04/2024 <br /> CITY OF EVERETT REVIEWED FOR PERMIT Fizz 152 O8 BUILDING CODE: 2018 IRC with WA State Amendments C e Z PAD, 8 SYSTEM TYPE: NFPA 13D 2019 Wet Sprinkler System • <br /> 150.6 Passive purge system without backfiow preventer 'j <br /> v <br /> City of Everett Permit Review o w O O �% 4 O O O SPRINKLER COVERAGE: 256 ftz Der sprinkler listina <br /> EVERETT Status:Approved as Noted o N 1296 SF 1221 Sp 1220 Sp 1525 SF 122p SF 1220 Sp 1220 Sp 1216 SF <br /> ....,..... SPRINKLER SPACING: 16-0"max.between heads. <br /> 04/04/2024 2:39:40 PMpp1 ppi PF5 153 1 FFci 8'-0"max.from any wall. <br /> ' PqD,i53.7 PAD* 53.j p '1535 A 151 1 pqD,152.8 8'-0"min.between heads. <br /> _751.7 ,157.7 �151.5 150.8 <br /> SEE RED LINES ON DROPS TO TOILETS pg0`750.3 pAD'16R3 ResRdenKaEfasDETAILS: <br /> ponse pendent sprinklers used throughout. d d <br /> �........... ............i i..............i .......... 9 HAZARD CLASSIFICATION: <br /> to <br /> 26 Residential use throughout. u° <br /> g � 663 SF <br /> PIPING DETAILS: o <br /> Blazemaster CPVC:Aboveground wet sprinkler system throughout except as noted on the F <br /> riser detail. s <br /> a <br /> / SUPPLY: C m n <br /> N 77`23'09" F 6"circulating water main supplies 1"tap and tube to combined domestic/fire meter.1" u•m` <br /> E 56.51 combined domestic/water meter supplies SYz"poly underground which runs to the system h Y u <br /> user. L y n d y <br /> ............. ...... ............IN.........._, ............ <br /> � MiL <br /> CPVC COMPATIBILITY: N <br /> J jq «O <br /> i A list of approved products for use with Blazemaster CPVC pipe is included with the product <br /> r----------• ........... r----------_ specifications booklet.For a complete and up-to-date product search, lease go to <br /> P P P Z <br /> I Fp'75 F I FF'1�3.7 pFT 153.3 <ping caused <br /> byo any <br /> pi.duds which <br /> Moore Fire Protection is not liable for damage to CPVC c u °L <br /> ' $�!153F'gDc 3'j F154.0 PAOc 6 Ap�75 piping caused by any products which are not approved for contact with it.Information .g <br /> 4 15.7pADo15 1 7 1.3 about products approved for contact can be found with the manufacturer. rn d sa153 FF'35 p5j.4 73 12 20 1{ 1j810 GENERAL NOTES AND LIABILITY F w " <br /> Z PA D>167 4 PAD,�Sj 4 PAd=151.4 1241 SF 118 Sp 1181 SF 1181 SF 1 SF 4y <br /> Install CPVC piping in accordance with manufacturer's instructions and UL listing including y m 0 <br /> N a but not limited to:hanging,vertical restraint,thermal expansion,chemical compatibility, ° `v a <br /> a 1� 16 15 E. <br /> concealment,and protection. Horizontal CPVC pipe shall be concealed with a minimum of w a E c n <br /> 12 3/8"gypsum board. All CPVC pipe shall be concealed. to x u <br /> 82 SF 1301 Sc 1301 Sp GRADE=153.4 GRADE=154.0 c a E <br /> All system piping is to be supported per manufacturer's specifications and is to be secured ` c `o. `ma <br /> PARCEL NO. SW GRADE=154.0 to to prevent lateral movement. Pipe is to be secured to prevent sprinkler head movement. r-x <br /> 00433600004801 �rn� Moore Fire Protection's warranty of work does not cover any damage due to freeze related ui a a <br /> GRADE=153.8 ^N problems. Wet piping shall be protected against temperatures below 50 degrees 999 <br /> e on with no insulation on the warm side of the a facing the heated interior. ' .. .' <br /> GRADE=154.8 ♦ 2 Fahrenheit. Insulation installed for this purpose shall be located on the cold side of the , i <br /> SW GRADE=154.0 pipe Y PP 9 a, i <br /> Coordinate with general and/or insulation contractor. All insulation to be by others. N <br /> GRADE=155.5 GRADE=155.9 a c <br /> Moore Fire Protection shall not be responsible for the ability of the structure to adequately y ;I t <br /> 22 ;23' 24 support the fire sprinkler system or any appurtenances thereof. J <br /> G - 1301 SF 130j SF 1300 Sp Owner is responsible for the periodic inspection,testing and maintenance of the water <br /> - based fire protection system(s)in accordance with the requirements of NFPA 13D Chapter <br /> ZQ 1g 19 20 21 12. i : <br /> y 1180 Sp 11 11 12 F1$ FFc.58 FF 15 r r <br /> z- 81 SF 81 SF 41 SF Pqq, 8 3 PAD • 3 pAD` 8 3 • Srh"Poly or equivalent supply brought in by others.* ... ... .: <br /> 1n 'FP1572 FF'FS FF^757 D,'576 : 156.3 �56.3 1156.3 '�.. <br /> Pgtl'155.2 PADc�552 PA�'7556 PA0;155.6 11/2"combination domestic/fire sprinkler shut off valve O M M #z <br /> i by others.Must be located before the domestic tee. J s b x <br /> r••••---- ••••• r •No monitoring is required. <br /> i 0 o <br /> o es # v N U w <br /> �i........ tic pressure-reducingo tva v <br /> E Srh"to nues to d by others An <br /> i domesIves,water softeners, <br /> E 4 O <br /> ws i O leak detectors,or other devices that will deter water m u v m O <br /> G = 3 •flow are to be on the domestic-only side of the tee. O <br /> 8 0 u Brass tee top outlet to be female-threaded to d r-I U r= o m <br /> " n accommodate male threaded CPVC adapter m o v <br /> �� G connection. m o oo w <br /> u.i Q I 0. <br /> 0 7 J <br /> C a �D 1%"PEX to domestic by others. N 9 M O N <br /> g hh"CPVC adapter with 11/2xl CPVC reducing bushing. W LLi ry v Z - m <br /> O MFP scope of work to begin here. 2 E o ¢ o <br /> w <br /> 1"check valve. V)Q d u ui v <br /> r-I LU <br /> N 76°1648"E -- F ` ® 1"tee with flow switch wired to exterior bell by .--I W 0. a Un o w <br /> 220.10 e v others. <br /> a <br /> c e 1"x 1"x 1"tee with 1"drain valve piped to collection <br /> u ®cup attached to sanitary sewer,left by plumber and <br /> m sized to accommodate the system flow demand of 27 O M <br /> \\ a O d .�Si gpm• <br /> I� <br /> SITE PLAN UNDERGROUND NOTES A m O 1"x 1"x 1/2"tee with 1h"x v4"bushing for pressure lU z a <br /> SCALE:1/16"=1'-0" 16 All underground to be by others. .r gauge.Three way valve included for pressure gauge. LLJ �i <br /> ❑A Modelled hydrant Flow location RISER SECTION KEYNOTE LEGEND LU v <br /> SCALE:1/2"=1'-0"❑ ON ,^ >B 6-in circulating water main • Part Tag LL `QJ <br /> WARNING SIGN: STUB IN: n •' <br /> 6.3.4 A warning sign,with minimum 1/4 in.letters,shall be affixed adjacent to the main *Builder to Provide 12"x 12"block out to protect piping. O �+ LU c <br /> ❑C Tap to 1-in combined domestic/fire fire service T ) shutoff valve and shall state the following: # Hydraulic Node Tag W ( ) <br /> p U (Typical for all units 9: FLUSH TEST: ry a <br /> WARNING:The water system for this home supplies fire sprinklers that require certain *Underground installer will be required to have a flush test completed and witnessed T ,�/ i> <br /> ❑.1 1-in combined domestic/fire meter(Typical for all units) flows and pressures to fight a fire.Devices that restrict the flow or decrease the pressure before Moore Fire will hook up to the incoming supply.Underground installer to provide a O Reference Tag I' L.L v <br /> or automatically shut off the water to the fire sprinkler system,such as water softeners, CMTC proving this test was done. LL O g <br /> filtration systems,and automatic shutoff valves,shall not be added to this system without PASSIVE PURGE SYSTEM SPECIAL NOTES: y <br /> ❑# Underground Note Tag <br /> ❑E VA-in poly combined domestic/fire underground to riser location by others*(Typical for all units) a review of the fire sprinkler system by a fire protection specialist. This is aFlow-through("passive purge")system.A 1h"female adapter will be left at the ,.,/ E <br /> remote toilet location.Plumber is to connect from adapter to toilet. ../ �: <br /> Do not remove this sign. Remote Area Tag Q <br /> Riser location-see this page for detail(Typical for all units) <br /> M <br />