Laserfiche WebLink
Permit K2406-011 <br /> Site Address: 3702 W Mukilteo Blvd Unit F �� �� �� HARBOR'S EDGE BLDG D NFPA z M <br /> Applicant: Matthew Steele . -. .. . <br /> Application Date:06/21/2024 0 1 3 D Z <br /> Description: Install new residential Flow-through system in townhouse _ 1 SITE SPECIFICATIONS LL O <br /> Review Date: 06/24/2024 ?) <br /> - AHI: City of Everett OWNER/LESSEE: Q <br /> A RELATED PERMIT: B2304-051 Sage Homes Northwest <br /> OCCUPANCY TYPE: Residential Everett 19thA Ave8 SE,Suite 118 Q J <br /> EVERETT WEST MUKILTEO BLVD. STORIES: PE. 3 B (425)609-8074 1-1 <br /> Everett Fire Dept.Permit Review 97+00 98+00 99+00 N 76U+OOB017'08"E 1016.80 100+00 <br /> PARCEL: 00433600004700 <br /> Status:Approved <br /> Reviewed By:KBrown GENERAL DESCRIPTION: <br /> 06/25/2024 1:26:49 New single family attached townhome.The typical and mirrored plans are both shown for <br /> PM reference.This submittal is for one plan-type only. <br /> 0 ------------------------- LEGAL DESCRIPTION: <br /> APPROVED EDGEWATER BLK 000 D-00-LOT 47 <br /> PUBLIC WORKS DEPARTMENT <br /> BY:THerman FIRE FLOW <br /> DATE:06/25/2024 340.17 <br /> CITY OF EVERETT REVIEWED FOR PERMIT HYD STATIC(PSI): 117 BOR STATIC(PSI): 104 <br /> RESIDUAL(PSI): 53 HYD ELEVATION(FT): 132.13 <br /> GRADE = GRADE= P FLOW(GPM): 1,331 MODEL REPORT DATE:02/03/23 <br /> GRADE=152.5 GRADE=151.6 SYSTEM SPECIFICATIONS <br /> Fizz BUILDING CODE: 2018 IRC with WA State Amendments <br /> Z PgD,1$28 SYSTEM TYPE: NFPA 13D 2019 Wet Sprinkler System 0 <br /> 150.8 Passive purge system without backflow preventer <br /> O <br /> 0.1 O O © AO SPRINKLER COVERAGE: 256 ftz per sprinkler listing � <br /> wp D <br /> o N 1296 SF 1221 SF 122o SF 1525 SF 1$25 SF 1220 SF 1220 SF 1220 SF 1216 SF <br /> SPRINKLER SPACING: 16'-0"max.between heads. <br /> FFc' FFi 1 FF;i PP 1S3.1 FFc' 8'-0"max.from any wall. <br /> ' ? PAD-15j� PADk157.� PAD;;5j.5 AD�157'j PAD'150.8 8'-0"min.between heads. <br /> PAD`750.3 PAD>760.3 PAD�150'g Residential fast E response pendent sprinklers used throughout. N d <br /> �........... ............i i.............. k-19............... <br /> �........... ............. �....... ......... 9 HAZARD CLASSIFICATION:.... .... a+ u <br /> to <br /> 26 Residential use throughout. u° <br /> g � 663 SF <br /> PIPING DETAILS: o <br /> Blazemaster CPVC:Aboveground wet sprinkler system throughout except as noted on the F <br /> riser detail. s <br /> a <br /> / SUPPLY: C m n <br /> N 77°23'09" 6"circulating water main supplies V tap and tube to combined domestic/fire meter.V u m` <br /> E 56.51 combined domestic/water meter supplies 1Yz"poly underground which runs to the system M Y u <br /> riser. L y a d y <br /> ............. ...... r........... .........._, ............ u. a <br /> ML <br /> CPVC COMPATIBILITY: N <br /> J jq «O <br /> i A list of approved products for use with Blazemaster CPVC pipe is included with the product <br /> / r----------• 1-----------� r--------- i I i specifications booklet.For a complete and up-to-date product search, lease go to/ ° P P P ,- <br /> I FF'75 F I FF'1�3.7 PFi 153.g <http://www.moorefire.com/cpvc>Moore Fire Protection is not liable for damage to CPVC c u °L <br /> 153 PqD_ 3.7 PF=1$q 0 PAD;)51 Ap=75j piping caused by any products which are not approved for contact with it.Information o. v u 2 g <br /> I I I 1'/{Dc75j 4 i 151.7 AD=1520 8. 7 � 3 about products approved for contact can be found with the manufacturer. rn F d s a <br /> FF,1s3. FF 36 Fr�15 S O 118 GENERAL NOTES AND LIABILITY <br /> Z PAD'15 4 PAD,13.4 pq 3.4 12q 1 118 SF 1181 SF 1181 SF 1 SF `o .c <br /> 14 ]51.4 Li-151.4 SF 4ti v <br /> Install CPVC piping in accordance with manufacturer's instructions and UL listing including y m <br /> N a but not limited to:hanging,vertical restraint,thermal expansion,chemical compatibility, ° 10 $ <br /> w a O GG concealment,and protection. Horizontal CPVC pipe shall be concealed with a minimum of 2 m C a <br /> V 1282 130 O 3/8"gypsum board. All CPVC pipe shall be concealed. (Ax u - <br /> SF 1 SF 1301 SF GRADE=153.4 GRADE=154.0 a <br /> All system piping is to be supported per manufacturer's specifications and is to be secured ` c n `ma <br /> PARCEL NO. SW GRADE=154.0 to to prevent lateral movement. Pipe is to be secured to prevent sprinkler head movement. 2Y <br /> Submittal for - <br /> 00433600004801 Bldg D Unit F only is 0 Moore Fire Protection's warranty of work does not cover any damage due to freeze related uj• OR <br /> GRADE=153.8 ^N problems. Wet piping shall be protected against temperatures below 50 degrees 999 <br /> e on with no insulation on the warm side of the a facing the heated interior. „ ••• .. .' <br /> GRADE 154.8 ♦ 2 Fahrenheit. Insulation installed for this purpose shall be located on the cold side of the , <br /> SW GRADE=154.0 pipe Y P�P 9 a. I <br /> Coordinate with general and/or insulation contractor. All insulation to be by others. N <br /> GRADE=155.5 GRADE=155.9 a c p <br /> Moore Fire Protection shall not be responsible for the ability of the structure to adequately <br /> - O O support the fire sprinkler system or any appurtenances thereof. J <br /> G - 1301 SF 7300 SF Owner is responsible for the periodic inspection,testing and maintenance of the water ;; 5 <br /> - based fire protection system(s)in accordance with the requirements of NFPA 13D Chapter :e t: a- >6 <br /> 12. V7Ve <br /> ZQ AO <br /> i <br /> y 7 jg0 SF 7781 1181 1241 PP6158.3 FF 75g 3 Srh"Poly ore equivalent supply brought in b others.* <br /> G FFa SF FFF FF,95 PAL],156. PAD`756. • Y q PPY 9 Y .................. <br /> 1T ;1572 FP`F.5 r157 76 I 3 I 3 .o <br /> PgL]`755.2 PADc�552 PA�,7556 PAD;155.6 11/2"combination domestic/fire sprinkler shut off valve O M M #z <br /> by others.Mu t be ocated efore the domestic tee. J s b x <br /> �••••---- ............ r •No monitoring is required. N ti <br /> i 0 a <br /> o es # v N U� <br /> �i........ tic pressure-reducingo tva m <br /> E 11/z"to nues to d by others.Any <br /> domesIves,water softeners, ,�E O <br /> ws i i O leak detectors,or other devices that will deter water Co D 8 iu m O <br /> .....-......' `........... ............. I i <br /> G = 3 •Flow are to be on the domestic-only side of the tee. O E.,be o t in 2: <br /> 8 0 u Brass tee top outlet to be female-threaded to d r-I U� o m <br /> m " O n accommodate male threaded CPVC adapter 100 <br /> m o v <br /> Gu connection. � m o oo w <br /> O.i Q 0 7 J <br /> C a �° 1%"PEX to domestic by others. N 3 c5 O N <br /> g hh"CPVC adapter with 11/2xl CPVC reducing bushing. W LLJ ;,� v un <br /> O MFP scope of work to begin here. 2 o ¢ o <br /> 1"check valve. M Q d u ui <br /> w v <br /> r-I LU <br /> N 76°1648"E -- r ` ® 1"tee with flow switch wired to exterior bell by .--I tD o w a to I] w <br /> 220.10 e m others. <br /> G M <br /> c e 1"x 1"x 1"tee with 1"drain valve piped to collection O Q N <br /> C u ®cup attached to sanitary sewer,left by plumber and m <br /> W sized to accommodate the system flow demand of 27 ,^ <br /> \ a _ O1-6 ."Si gpm• V 3 <br /> SITE PLAN UNDERGROUND NOTES A m O 1"x 1"x 1/2"tee with 1h"x v4"bushing for pressure u <br /> SCALE:1/16"=1'-0" 16 All underground to be by others. .r gauge.Three way valve included for pressure gauge. 11 I m <br /> ❑A Modelled hydrant Flow location RISER SECTION KEYNOTE LEGEND LU LC <br /> SCALE:1/2"=1'-0" 0 <br /> ❑B 6-in circulating water main • Part Tag QV p <br /> WARNING SIGN: STUB IN: m <br /> 6.3.4 A warning sign,with minimum 1/4 in.letters,shall be affixed adjacent to the main *Builder to Provide 12"x 12"block out to protect piping. O w m <br /> ❑C Tap to 1-in combined domestic/fire service(Typical for all units) shutoff valve and shall state the following: #FLUSH TEST: Hydraulic Node Tag W <br /> �/ 'a <br /> WARNING:The water system for this home supplies fire sprinklers that require certain Underground installer will be required to have a flush test completed and witnessed LPL m <br /> ❑D 1-in combined domestic/fire meter(Typical for all units) flows and pressures to fight a fire.Devices that restrict the flow or decrease the pressure before Moore Fire will hook up to the incoming supply.Underground installer to provide a O Reference Tag °w <br /> or automatically shut off the water to the fire sprinkler system,such as water softeners, CMTC proving this test was done. LL O _ <br /> filtration systems,and automatic shutoff valves,shall not be added to this system without PASSIVE PURGE SYSTEM SPECIAL NOTES: M y <br /> # Underground Note Tag W <br /> ❑E VA-in poly combined domestic/fire underground to riser location by others*(Typical for all units) a review of the fire sprinkler system by a fire protection specialist. This is aFlow-through("passive purge")system.A 1h"female adapter will be left at the � E <br /> remote toilet location.Plumber is to connect from adapter to toilet. ?� <br /> Do not remove this sign. �# Remote Area Tag Q N <br /> ❑F Riser location-see this page for detail(Typical for all units) T o <br /> M <br />