My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3614 SHORE AVE 2025-08-18
>
Address Records
>
SHORE AVE
>
3614
>
3614 SHORE AVE 2025-08-18
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/18/2025 3:56:27 PM
Creation date
5/30/2025 8:05:55 AM
Metadata
Fields
Template:
Address Document
Street Name
SHORE AVE
Street Number
3614
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
83
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Simple Heating System Size: Washington State <br /> This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Washington State Energy Code(WSEC)and ACCA <br /> Manuals J and S.This tool will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to determine cooling loads. <br /> Please complete the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section,some <br /> values will be calculated for you.If you do not see the selection you need in the drop-down options,please contact the WSU Energy Program at <br /> energycode@energy.wsu.edu or(360)956-2042 for assistance. <br /> Project Information Contact Information <br /> Lott Shore Avenue Hayward Homes <br /> Meeting System Type: O All Other Systems ' 'Heat Pump <br /> To see detailed instructions for each section,place your cursor on the word"Instructions" �„_ <br /> Instructions Design Temperature Difference 49 <br /> Everett Pane AFB .\T=Indoor(70 degrees)-Outdoor 7 sign Temp <br /> ;,. . SEP 1 1 2023 �1 <br /> Conditioned Floor Area <br /> Instructions Conditioned Floor Area(sq ft) 3,298 r,��77''jj'' <br /> Average Ceiling Height Condition tl'F/i31t e OF EVERETT <br /> Instructions Average Ceiling Height(ft) 8.8 28,858 ermit Services <br /> Glazing and Do,. U-Factor X Area = UA <br /> Instructions <br /> u-o 28 . 0.280 527 147.56 <br /> Skylights U-Factor X Area = UA <br /> Instructions 0.50 0 <br /> Insulation <br /> Attic U-Factor X Area = UA <br /> Instructions 0.026 2,123 55.20 <br /> R-a9 <br /> Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA <br /> Instnictions 0 <br /> V�Vjultec Ce,r.rus i,i;!i>pioje(t. V <br /> Above Grade Walls(see Figure a) U-Factor X Area UA <br /> Instructions 0.056 3,018 169.01 <br /> R-21 Intermediate <br /> Floors U-Factor X Area UA <br /> Instructions 0.025 2,168 54.20 <br /> R <br /> Below Grade Walls(see Figure 1) U-Factor X Area UA <br /> Instructions 0.028 0 <br /> No Below Grade Walls in this project. <br /> Slab Below Grade(see Figure 1) F-Factor X Len•th UA <br /> Instructions 0.303 0 <br /> Na Slab Below Grade in this project. • --- <br /> Slab on Grade(see Figure 1) F-Factor X Len•th UA <br /> Instructions 0 <br /> No Slab on Grade in this pre ect. V <br /> Location of Ducts <br /> Instructions Duct Leakage Coefficient <br /> Conditioned Space y <br /> - -- 1.00 <br /> Sum of UA 425.97 <br /> Envelope Heat Load 20,872 Btu/Hour <br /> Figure 1. Sum of UA x 1T <br /> _ Air Leakage Heat Load 15,271 Btu/Hour <br /> Volume x 0.6 x.1T x 0.018 <br /> Above Grade Building Design Heat Load 36,144 Btu/Hour <br /> Air leakage+envelope heat loss <br /> Building and Duct Heat Load 36,144 Btu/Hour <br /> Ducts in unconditioned space:sum of building heat loss x 1.10 <br /> Ducts in conditioned space:sum of building heat loss x 1 <br /> Maximum Heat Equipment Output 45,180 Btu/Hour <br /> Building and duct heat loss x 1.40 for forced air furnace <br /> Building and duct heat loss x 1.25 for heat pump <br /> (07/01/13) <br />
The URL can be used to link to this page
Your browser does not support the video tag.