Laserfiche WebLink
Page 3 of 29 <br /> Ross project: HAWARD HOMES LOT 1 by: RR sheet#: <br /> Engineering location: 36xx SHORE AVENUE,EVERETT,WA date: 6/16/2022 <br /> Design client: THE LEREN COMPANY job#: 2027 <br /> Inc <br /> Governing Codes <br /> General - 2018 International Building Code <br /> Wood - ANSI/AF&PA NDS-2018 <br /> ANSI/AF&PA SDPWS-2018 <br /> Loads- ASCE/SEI 7-16 <br /> Concrete- ACI 318-14 <br /> Default Roof Loads <br /> Dead Load <br /> Sheathing Rafter Roof Truss Roof Min.w/Uplift For Lateral <br /> Roofing 3.50 psf 3.50 psf 3.50 psf 2.00 psf 3.00 psf <br /> Sheathing 1.50 * * 1.00 1.50 <br /> Insulation 1.00 1.00 1.00 <br /> Sprinkler <br /> Ceiling 2.50 2.50 2.50 <br /> Rafters/Trusses * 4.00 2.00 4.00 <br /> Mechanical 1.00 1.00 1.00 <br /> Solar <br /> Misc 0.50 4.00 4.00 _ 1.00 <br /> Total 5.50 psf 12.00 psf 16.00 psf 6.00 psf 13.00 psf <br /> *Included in RISA self weight <br /> Snow Load Ground Snow Load Pg= Pg= 20.0 psf <br /> Minimum Roof Snow Load= 25 psf <br /> Exposure Factor Ce= Ce= 1.0 <br /> Thermal Factor Ct= Ct= 1.0 <br /> Slope Factor Cs= Cs= 1.0 0.7CeCtCslsPg <br /> Design Roof Snow Load Ps= Ps= 14 psf = <br /> 25 psf minumum roof snow load controls <br /> Default Wood Floor Loads <br /> Dead Loads <br /> Sheathing Joist Floor Truss Floor For Lateral <br /> Floor Covering 3.50 psf 3.50 psf 3.50 psf 2.00 psf <br /> Gyperete <br /> Sheathing 2.50 * * 2.50 <br /> Insulation <br /> Sprinkler <br /> Ceiling 2.50 2.50 2.50 <br /> Joist/Truss * 3.00 2.00 <br /> Mechanical 1.00 1.00 1.00 <br /> Misc 1.00 3.00 3.00 1.00 <br /> Total 7.00 psf 10.00 psf 13.00 psf 11.00 psf <br /> *Included in RISA self weight <br /> Live Loads <br /> Residential 40 psf <br /> Balcony 60 psf where applicable <br />