Energy Program <br />WsSii iw,.-roN STvrr. Umwwsny <br />Residential Building Air Leakage <br />(Blower Door) Test Results <br />Permit #: <br />House address or lot number: <br />3614 Shore Ave <br />City, ZIP <br />Everett, WA <br />Cond. Floor Area (sf): <br />3300 <br />Age of house: <br />new <br />Source (circle one): <br />Plans Estimate Measured <br />Results shall be reported as Air Changes per Hour at 50 Pascals (ACH50) and shall be calculated as follows: <br />Where: <br />ACH50 = (CFM50 x 60)/ Volume <br />CFM50 = Blower door fan flow at 50 Pascal pressure difference <br />Volume = Conditioned Floor Area of the housing unit x ceiling height <br />Blower Door Test Result: 1.8 ACH50 <br />1038 CFM@50Pa <br />Ring circle one if applicable): <br />O e A B C <br />Blower Door Fan Location: <br />Front <br />Weather Conditions: <br />sunny <br />I certify that these blower door results are accurate and determined using standard industry protocol: <br />Company Name: <br />GPI <br />Technician: <br />Eduardo Nuno <br />Technician Signature: <br />Date: <br />03/07 24 <br />Phone Number: <br />(360) 630-6341 <br />2018 WSEC reference: <br />R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not <br />exceeding 5 ACH50. Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals). <br />For this test only, the volume of the home shall be the conditioned floor area on ftz (mz) multiplied by 8.5 feet (2.6 m). <br />Where required by the code official, testing shall be conducted by an approved third party. A written <br />report of the results of the test shall be signed by the party conducting the test and provided to the code <br />official. Testing shall be performed at any time after creation of all penetrations of the building thermal <br />envelope. Once visual inspection has confirmed sealing (see Table R402.4.1.1), operable windows and <br />doors manufactured by small business shall be permitted to be sealed off at the frame prior to the test. <br />During testing: <br />1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended <br />weatherstripping or other infiltration control measures; <br />2. Dampers including exhaust, intake, makeup air, backdraft and flue shall be closed, but not sealed beyond <br />intended infiltration control measures; <br />3. Interior doors, if installed at the time of the test, shall be open. Access hatches to conditioned crawl spaces <br />and conditioned attics shall be open; <br />4. Exterior openings for continuous ventilation systems and heat recovery ventilators shall be closed, sealed; <br />5. Heating and cooling systems, if installed at the time of the test, shall be turned off; and <br />6. Supply and return registers, if installed at the time of the test, shall be fully open. <br />