Laserfiche WebLink
H <br />FRAMING NOTES <br />Roof Framing: <br />Provide continuous 2x solid blocking for rafters at the supports and 1 X3 or approved <br />metal cross bridging at 8'-0" maximum spacing. All vertically laminated beams and <br />headers shall be spiked together with 16d nails at twelve (12) inches on center unless <br />noted otherwise. Provide cut washers for all bolt heads and nuts bearing on wood. <br />Bearing Wall Framing: <br />For the top two stories, all exterior wood framed bearing walls are 2X6 at 16" on center <br />and interior bearing walls are typically 2X4 at 16" on center. All door and window <br />headers not called out on the plans shall be (2) 2X 10 with one cripple and one stud each <br />end for openings 4'-0" wide or less, and two cripples and one stud each end for openings <br />more than 4'-0" wide. All columns not called out on the plans shall be two studs. Spike <br />laminated columns together with 16d nails at 16" on center. Provide one layer of asphalt <br />impregnated building paper (40#) or use pressure treated material at all contact surfaces <br />between any wood and concrete or masonry. No soil to be in contact with any wood <br />surfaces. <br />