Laserfiche WebLink
-qqw ZAP ENERGY <br /> I <br /> ZRD-SPL-001 <br /> Table 2 Occupancies of the locations and the distances from the area to the FuZE-Q source. <br /> Dose limit Annual dose Annual <br /> Distance to the <br /> Label on for shielding without dose with <br /> Location Description Type of Area Occupancy FUZE-Q source <br /> the map (m) design shielding shielding <br /> (mrem/y) (mrem/y) (mrem/y) <br /> 1 East wall - North Unrestricted 5.0% 7.6 2000 303 233 <br /> 2 East wall - FuZE-Q location Unrestricted 5.0% 6.5 2000 954 201 <br /> 3 East wall - Emergency exit Unrestricted 5.0% 9.4 2000 313 39 <br /> HV Lab South <br /> 4 (Outside the windows) Unrestricted 5.0% 16.9 2000 137 45 <br /> 5 HV South (Outside the door) Unrestricted 5.0% 17.2 2000 159 48 <br /> 6 Control Room Controlled Area 100.0% 14.2 100 425 86 <br /> 7 Building North (Bay doors) Unrestricted 5.0% 11.8 2000 128 27 <br /> Building North <br /> 8 Unrestricted 5.0% 17.6 2000 152 79 <br /> (Roll up door/emergency exit) <br /> 9 Machine shop Unrestricted 100.0% 23.0 100 203 54 <br /> 10 HV Lab Unrestricted 50.0% 11.5 200 347 84 <br /> 11 Technician area Unrestricted 100.0% 23.9 100 183 38 <br /> 12 Suite 101 offices Unrestricted 100.0% 25.9 100 147 32 <br /> 13 Vacuum Parts Preparation Room Unrestricted 50.0% 18.3 200 188 62 <br /> Controlled <br /> 14 Neutronics Lab Area* 20.0% 22.3 500 223 50 <br /> 15 Suite 100 offices Unrestricted 100.0% 19.3 100 170 34 <br /> 16 Roof Unrestricted 5% 8.7 2000 1146 1220 <br /> * Controlled area for control of radioactive materials stored in this area. <br /> Zap Energy Inc. Proprietary Information <br /> 9 <br />