My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5901 23RD DR W ZAP ENERGY 2025-08-04
>
Address Records
>
23RD DR W
>
5901
>
ZAP ENERGY
>
5901 23RD DR W ZAP ENERGY 2025-08-04
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/4/2025 11:31:43 AM
Creation date
5/30/2025 8:11:21 AM
Metadata
Fields
Template:
Address Document
Street Name
23RD DR W
Street Number
5901
Tenant Name
ZAP ENERGY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
241
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Air System Design Load Summary for HP8 with common ERV DOAS <br />Project Name: EVE ZAP ENERGY-v5-11 10/22/2024 <br />Prepared by: HERM_ANSON COMPANY LLP 11:17AM <br />DESIGN COOLING <br />DESIGN HEATING <br />COOLING DATA AT Sep 1500 <br />COOLING OA DB / WB 84.0 °F / 64.0 °F <br />HEATING DATA AT DES HTG <br />HEATING OA DB / WB 19.0 °F / 14.8 °F <br />ZONE LOADS <br />Details <br />Sensible <br />(BTU/hr) <br />Latent <br />(BTU/hr) <br />Details <br />Sensible <br />(BTU/hr) <br />Latent <br />(BTU/hr) <br />Window & Skylight Solar Loads <br />50 ftZ <br />2920 <br />50 ftz <br />- <br />Wall Transmission <br />1354 ft2 <br />2010 <br />1354 ftZ <br />7487 <br />Roof Transmission <br />0 ftZ <br />0 <br />0 ftZ <br />0 <br />Window Transmission <br />50 ftZ <br />105 <br />50 ftZ <br />1007 <br />Skylight Transmission <br />0 ftZ <br />0 <br />0 ftZ <br />0 <br />Door Loads <br />0 ftZ <br />0 <br />0 ftZ <br />0 <br />Floor Transmission <br />1912 ftZ <br />423 <br />1912 ftZ <br />1518 <br />Partitions <br />0 ftZ <br />0 <br />0 ftZ <br />0 <br />Ceiling <br />0 ftZ <br />0 <br />0 ftZ <br />0 <br />Overhead Lighting <br />1611 W <br />5090 <br />0 <br />0 <br />Task Lighting <br />0 W <br />0 <br />0 <br />0 <br />Electric Equipment <br />2160 W <br />7135 <br />- <br />0 <br />0 <br />- <br />People <br />16 <br />3467 <br />3280 <br />0 <br />0 <br />0 <br />Infiltration <br />- <br />0 <br />0 <br />- <br />0 <br />0 <br />Miscellaneous <br />0 <br />0 <br />- <br />0 <br />0 <br />Safety Factor <br />0%/0% <br />0 <br />0 <br />15% <br />1502 <br />0 <br />>> Total Zone Loads <br />21152 <br />3280 <br />11514 <br />0 <br />Zone Conditioning <br />- <br />21879 <br />3280 <br />- <br />11338 <br />0 <br />Plenum Wall Load <br />0% <br />0 <br />- <br />0 <br />0 <br />- <br />Plenum Roof Load <br />0% <br />0 <br />0 <br />0 <br />Plenum Lighting Load <br />0% <br />0 <br />0 <br />0 <br />Exhaust Fan Load <br />195 CFM <br />0 <br />- <br />195 CFM <br />0 <br />- <br />Ventilation Load <br />195 CFM <br />823 <br />-457 <br />195 CFM <br />4169 <br />0 <br />Ventilation Fan Load <br />195 CFM <br />180 <br />- <br />195 CFM <br />-180 <br />- <br />Space Fan Coil Fans <br />- <br />279 <br />- <br />-193 <br />Duct Heat Gain / Loss <br />0% <br />0 <br />- <br />0% <br />0 <br />- <br />>> Total System Loads <br />23162 <br />2823 <br />15133 <br />0 <br />Terminal Unit Cooling <br />23161 <br />2846 <br />0 <br />0 <br />Terminal Unit Heating <br />0 <br />- <br />15133 <br />- <br />>> Total Conditioning <br />23161 <br />2846 <br />15133 <br />0 <br />Key: <br />Positive values are clg loads <br />Negative values are htg loads <br />Positive values are htg loads <br />Negative values are clg loads <br />Hourly Analysis Program 5.11 Page 6 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.