My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3927 RUCKER AVE BASE FILE 2025-07-21
>
Address Records
>
RUCKER AVE
>
3927
>
BASE FILE
>
3927 RUCKER AVE BASE FILE 2025-07-21
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/21/2025 9:10:07 AM
Creation date
5/30/2025 8:11:26 AM
Metadata
Fields
Template:
Address Document
Street Name
RUCKER AVE
Street Number
3927
Tenant Name
BASE FILE
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
61
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
©MacDonald -Miller <br />FACILITY SOLUTIONS<^) <br />October 30, 2024 <br />Cal Bearman, P.E. <br />Bldg Plans Examiner <br />City of Bellevue <br />3200 Cedar St — 2nd Floor <br />Everett, WA 98201 <br />RE: Review comments correction: 77243205 TEC-GUNDERSON HUMIDIFIER REPL I M2409-076 <br />Permit Number: M2409-076 <br />M M FS#: 77243205 <br />Dear Cal: <br />We are in agreement with you comment responses and have had the structural engineer redo <br />the calculations. The revised calculations have been consolidated into drawing sheets S-1, S-2, <br />S-3, S-4 and attached to the end of the Mechanical drawing set. Your review comments have <br />been reprinted below in italics and are followed by our responses. <br />City Comment #1: 1. The drawings or structural analysis should demonstrate that the new units <br />do not increase the previous loading condition on the roof by more than 5%. The weight of all <br />accessory components (e.g., mounting support structure, operating weight with fluid, etc.) <br />should be included. If the load increase exceeds 5%, a structural analysis of the supporting <br />framing is required. See IEBC Section 706.2. <br />MMFS Response: Calculations have re -done and have been consolidated into drawing sheets <br />S-1, S-2, S-3, S-4 and attached to the end of the Mechanical drawing set. <br />City Comment #2: If installation of the units requires substantial structural modifications to <br />the supporting framing, a building permit will be required. The application should <br />include drawings and calculations for the proposed modifications. Minor modifications <br />(e.g., blocking between existing framing) may be performed within the scope of the <br />mechanical permit application. <br />MMFS Response: No significant structural modifications required to the building. <br />Comment #3: The mechanical drawings should include the structural sheets as they reference <br />the installation to be per structural details. <br />MMFS Response: The revised calculations and associated sketches have been consolidated <br />into drawing sheets S-1, S-2, S-3, S-4 and attached to the end of the Mechanical drawing set. <br />macmiller.com 1-800-962-5979 WASHINGTON & OREGON <br />
The URL can be used to link to this page
Your browser does not support the video tag.