Laserfiche WebLink
PHASING LEGEND <br />EXISTING CONSTRUCTION TO REMAIN <br />_ _ = ITEMS TO BE DEMOLISHED <br />NEW CONSTRUCTION <br />A3.2 <br />A3.2 <br />EXISTING CONSTRUCTION TO MEET NEW SHEAR WALL <br />CRITERIA- SEE STRUCTURAL <br />24'-6"± <br />9" t <br />9'-3"t 1'-2" 9'-3"± L 3'-1Y2.'± 17'-4" <br />L 1 <br />,-8" 21'-10" <br />102 <br />I <br />103 1'-y^ <br />I I <br />20'-3"t 5'-10"t <br />101_8" y,_�. 2'-3" L 2'-5Y2" 1-15' <br />L----- P --J <br />O1 <br />24'-9"t <br />2 <br />" 13'-2^ L 6'_1" <br />-------- --- <br />a a <br />O <br />1V- "RCHx,5'-3" <br />EG SS EG SS <br />- — — — <br />,60 <br />— — — 100 O2 2 <br />GARAGE 0 24'-5" z" <br />- <br />1o'-z" " <br />O N <br />23'-6" x 23'-5" <br />EDROOM <br />BED #5 <br />4TIC20 <br />9'-8" x 12'-0"1 <br />V-2" x 12'-0" - <br />- C- <br />LIVI G RO I <br />19-9" x 15'-3" <br />200 <br />SC143 <br />S 3' S-6' <br />r❑ <br />SCf 5' 3' , <br />3 <br />205 7, 6„ <br />16 9" 7-1' 4-0' <br />_ <br />-------� C- — --- <br />15 <br />11 REF. <br />�� <br />— � 4i_ <br />ANTRYI �� <br />�BTH#2 <br />g10" <br />BEDFQbOM #3 - <br />s'� x 1� <br />0'-5" <br />Ll G <br />211 <br />WLAUND Y <br />BATH #1 71-3" x 11' 7" DINING ROOM <br />5'-8" x i '-7" D 16'-0" x 12'-0' <br />5'-10" 7'-9" 16'-0" <br />5'-2 x�' <br />r 5'-6" <br />�StCD <br />— 3'-1" <br />1� <br />�i SCD <br />14 219 <br />O KITCHEN s <br />5 O 16'-0" x 17'-3" <br />212 ^ <br />16 215 v� <br />F0 <br />O `J 1 o <br />I 7 <br />1 <br />L � SCD <br />208 <br />O <br />7 <br />O <br />3. <br />a <br />- — <br />- <br />------ __jL M <br />----------__�--� -- <br />------�-- <br />= <br />Sx3 -- <br />-11" 4'-0" 8'-3" <br />SUI 5' <br />14 <br />14 218 <br />SC <br />��� <br />O2'-7" <br />g <br />214 00 <br />217 <br />14 213 <br />1 <br />ST-D11" 7'10�2" 8'��2 �T-0" 8'-10"c, <br />17'-0" x 15'-8" <br />209 <br />O <br />8 <br />O <br />O <br />I <br />op <br />I <br />BEDR <br />11'-9" <br />OM <br />#2 <br />" <br />BEDROOM #1 <br />11-5" x 14'-8" <br />OUTDOOR ROOM <br />15'-9" x 15'-0" <br />O EGR SS <br />6,-0.1 6'-7y2^ <br />12'- <br />10 <br />y2" <br />13 EG <br />SS <br />6'-41/2" <br />5'-8�2" <br />12 EG <br />— 6, " — <br />SS <br />6'-2/2' <br />------- <br />-- <br />12'-1" <br />12'-5" <br />16'-3" <br />15'-10" <br />MAIN FLOOR PLAN <br />SCALE 1/4"= V-0" <br />0' 4' 8' <br />A3A.2 A3C�.2 <br />PROJECT <br />NORTH <br />(I <br />PLAN GENERAL NOTES <br />1. WALLS, CEILING AND FLOOR INSULATION; AND WINDOW AND <br />DOOR GLAZING TO BE IN ACCORDANCE 2018 WSEC. SEE SHT. <br />A0.1. <br />2. TEMPERED SAFETY GLAZING TO BE PROVIDED PER 2018 IRC <br />SECTION R308.4; SEE ELEVATIONS OR WINDOW SCHEDULE FOR <br />LOCATIONS. <br />3. INSTALL 110V SMOKE DETECTORS, INTERCONNECT W/ BATTERY <br />BACKUP, PER 2018 IRC WA STATE AMENDMENTS SECTION R314; <br />SEE PLANS FOR LOCATIONS. <br />4. INSTALL CARBON MONOXIDE DETECTORS PER 2018 IRC WA <br />STATE AMENDMENTS SECTION R315; SEE FLOOR PLAN FOR <br />LOCATIONS. <br />5. INSTALL WHOLE HOUSE VENTILATION FAN PER 2018 IRC WA <br />STATE AMENDMENTS SECTION M1507.3: SYSTEM SHALL PROVIDE <br />MIN. CFM PER TABLE M1507.3.3(1). <br />6. ALL EXHAUST FANS TO BE LOCATED AND SIZED PER 2018 IRC <br />WA STATE AMENDMENTS TABLE M1507.4. <br />7. FAN NOISE RATING TO BE 1.5 SONE OR BETTER <br />PLAN KEYNOTES <br />iO. 110V COMBINATION SMOKE & CARBON MONOXIDE <br />DETECTOR INTERCONNECT W/ BATTERY BACKUP <br />TYP. <br />O2. ROOF LINE ABOVE OR WALL BELOW. <br />O 90 CFM, LE SONO BATH ENERGY STAR FANS WITH 4" <br />SMOOTH DUCTING. (MIN. 90 CFM FOR CONTINUOUS <br />OPERATING WHOLE HOUSE FAN IN ACCORDANCE WITH <br />SEC. M1507.3.30) <br />U.L. APPROVED PROPANE BURNING FIREPLACE <br />Q5. DRYER -VENT TO OUTSIDE <br />EXHAUST TERMINATION - IN ACCORDANCE WITH IRC <br />M1507.3.4.4 <br />Q7. PROVIDE EMERGENCY ESCAPE OPENING IN ALL <br />SLEEPING ROOMS MIN. 24" HIGH X 20" WIDTH AND 5.7 S.F. <br />CLEAR OPEN AREA IN ACCORDANCE WITH IRC R310.1 <br />22" X 30" ATTIC ACCESS - WITH MIN. UNOBSTRUCTED <br />\ HEADROOM ABOVE HATCH OF 30" - EXISTING VERIFY <br />T\ Q RANGE WITH 300 CFM HOOD <br />10. 5/8" TYPE-X GWB ON ALL WALLS & CEILING AND AROUND <br />ALL BEAMS AND POSTS. <br />11. SOLID CORE DOOR W/ SELF CLOSER <br />12. TOWEL WARMER (NOT USED) <br />13 5/8" TYPE X GWB UNDER STAIR <br />14 ROD & SHELF <br />DOOR & WINDOW NOTES <br />1. SEE SHT. A0.1 FOR 2018 WSEC REQUIREMENTS; ALL <br />EXTERIOR DOORS AND WINDOWS SHALL COMPLY. <br />2. SEE FLOOR PLAN FOR SLIDING / POCKET DOOR ACTIVE <br />DOOR PANEL LOCATIONS AND DIRECTIONS. <br />l^ <br />V / <br />3. SEE ELEVATIONS FOR OPERABLE WINDOW SASH <br />7 <br />DIRECTIONS. <br />4. ALIGN WINDOW AND DOORS HEADS -TYP. <br />L <br />O <br />AREA CALCULATIONS <br />Q <br />0-1 <br />EXISTING FINISHED 1,731 S.F. <br />PROPOSED FINISHED 835 S.F. <br />TOTAL HEATED AREA 2,566 S.F. <br />J <br />GARAGE 570 S.F. <br />0 <br />Z <br />lQ <br />VJ <br />PROJECT PHASE — MAIN FLOOR PLAN <br />