Laserfiche WebLink
Scott Schreffler <br /> From: Scott Schreffler <br /> Sent: Thursday, December 12, 2024 8:09 AM <br /> To: 'ft142003@yahoo.com' <br /> Subject: B2410-068 -4629 W VIEW DR <br /> Good morning, <br /> I am reviewing your application for building permit, and more information is needed to continue my review. <br /> The AFH has a checklist for the inspectors and the State licensing agency. Before the inspection can occur, we perform <br /> plan review,which documents the revisions to the building for public safety. The plan submitted does not contain <br /> enough information for us to make that determination. Please revise and resubmit as follows: <br /> 1. Please provide a floorplan showing the current uses of the work area and the existing nature of the building <br /> BEFORE the AFH conversion. <br /> 2. The current floor plan is not legible. All drawings should be legible as they are a permanent public record of the <br /> life safety of the structure. <br /> 3. A bedroom requires smoke alarms, emergency egress windows, heat, minimum ceiling height, etc., all of which <br /> must be shown on the proposed floor plan. This is regulated by the International Residential Code. <br /> 4. Depending if the room was previously heated or not,the Energy Code may also apply. <br /> 5. Bedrooms require electricity, which is governed by the National Electrical Code, and would require an electrical <br /> permit if the room needs to be upgraded to be a bedroom. The requirements for a bedroom are different than <br /> storage, or a garage, or other room types. The existing use of the room determines the extent of the code <br /> requirements. <br /> 6. All of this needs to be clear in your submittal to continue my review. <br /> Please carefully review the step-by-step process for permit requirements on the City's Permit Services website, located <br /> here: STEP 1: Getting started I Everett,WA-Official Website <br /> Also, please carefully follow the resubmittal instructions located <br /> here: https://www.everettwa.gov/DocumentCenter/View/35938 <br /> Failure to follow these instructions carefully will likely delay your permit review if we require more revisions, so please <br /> carefully follows these instructions. A design professional may not be required, but can be helpful to facilitate your <br /> approval. <br /> Let me know if you have any questions. <br /> Regards, <br /> — Scott Schreffler, Registered Architect <br /> Senior Building Plans Examiner I Permit Services <br /> 425.257.8810 13200 Cedar Street, 2nd Floor, Everett,WA 98201 <br /> EVERETT Phone Hours: M-F: 8:30 a.m.—12 p.m & 1 p.m.—3 p.m. <br /> everettwa.gov/permits I Facebook I Twitter <br /> Note:Emails and attachments sent to and from the City of Everett are public records and may be subject to disclosure pursuant to the Public <br /> Records Act. <br /> 1 <br />