My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3406 NORTON AVE 2025-10-24
>
Address Records
>
NORTON AVE
>
3406
>
3406 NORTON AVE 2025-10-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/24/2025 9:03:03 AM
Creation date
5/30/2025 9:16:18 AM
Metadata
Fields
Template:
Address Document
Street Name
NORTON AVE
Street Number
3406
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DISCLOSURE: <br />ALL DIMENSIONS & SIZE DESIGNATIONS GIVEN <br />ARE SUBJECT TO VERIFICATION ON JOBSITE & <br />ADJUSTMENT TO FIT UNFORESEEN JOB <br />CONDITIONS. DESIGN PLANS ARE NOT PROVIDED <br />FOR ARCHITECTURAL OR ENGINEERING USE. <br />PROJECT INFORMATION: <br />ADDRESS: <br />3406 NORTON AVE, EVERETT WA 98201 <br />PARCEL NUMBER: <br />00437562702900 <br />PROPERTYOWNER: <br />VICKI HOYLE AND VICTOR CHRISTENSEP <br />PROJECT CONTACT: <br />Selena Fitch <br />Fitch Design Company <br />425-4B1-9190 <br />Selena@FUchDeslgnCom W ny.mm <br />LEGAL DESCRIPTION: <br />NEI/45EC30 T29N RSE <br />JURISDICTION: <br />CITY OF EVERETT <br />BUILDINGCODE: <br />20211BC <br />ENERGY CODE: <br />2021 WSEC <br />PLUMBING CODE: <br />2021 UNIFORM PLUMBING CODE <br />ZONING: <br />R-1 <br />SCOPE OF WORK: <br />KITCHEN REMODEL <br />GENERAL NOTES: <br />1. All work to comply with 2021 Imemadonal Building Code and <br />2021 International Residential Code with local amendment. <br />2. Verity all dimensions and field conditions before beginning work <br />and notify designer of any discrepancies. <br />3. Provide solid wood blocking for support at all wall mounted <br />Raw". <br />4. Provide approved daftstupping In concealed space between <br />ceiling and floor; and approved firesiopping In walls per code. <br />S. Flash all openings with minimum 26 gauge steel (galvanized or <br />factory finish). <br />6. All wood In contact with concrete or masonry to be pressure <br />treated. <br />LIFE SAFETY NOTES: <br />1. Stairways to meet minimum requirements of 20211RC R311.7; <br />- Mlnlmum stair width: 39 <br />- Mlnlmum headroom: S0' <br />- Maximum riser height 7 31V <br />- Minimum tread depth: 10' <br />- Rise or ton dimensions shall not vary more than 3/0" <br />- Minimum landing length: 36" <br />Randall height 34.38" above stair nosing <br />2. Stairways with four or more risers shall have a handrail. <br />3. Handralls shall be continuous and terminate at a wall or newel <br />past <br />4. Guards shall be provided for porches, balconies or raised floor <br />surfaces located more than 30" above the floor or grade below. <br />S. Guards shall be 36" In height and designed to resist a 200 lb. <br />concentrated load on the top all and SO psf on all guardrail <br />Infill component. <br />6. Required guards shall have a maximum opening such thata 4" <br />diameter sphere an not pass through. <br />7. All new smoke and carbon monoxide detectors to be hardwired <br />with a battery back-up. <br />ENERGY NOTES: <br />1. All new fenestration U-.)... and Insulation R-values shall satisfy <br />the prescriptive path of the 2021 Washington State Energy Cade. <br />2. Prescriptive Requirements (Climate zone 4C); <br />- Vertical glazing: U = 030 <br />- Overhead glazing: U =0.50 <br />- Doors: U = 0.20 <br />- Ceilings: R-49 <br />- Single after ceilings: R-38 <br />- Walk Cabove grade): R-21(w/ headers Insulated R-10) <br />- Walls (below grade): 10/15/21 tnt.TB <br />- Floors: R-30 <br />- Slab on gate: R-10 (24' per(meter) <br />3. When insulation is Installed In a cavity which is less than the label <br />or design thickness of the insulation, the compressed R-value <br />of the Insulation shall not be less than specified above. <br />4. Builder shall complete and past an insulation "Certificate for <br />Residential Construction' within three feet of the electrical <br />panel prior to final Inspection. <br />S. Blower door testing air leakage shall not exceed three air <br />changes per hour. A written report of blower door test result <br />shall be signed by the testing party and provided to the building <br />Inspector prior W call for final inspection. <br />6. Aminimum of 90% of permanantiy Installed lamps In lighting <br />flxwres shall be high efficacy, lamps. <br />7. Kitchen, Bathroom and laundry exhaust fart shall terminate <br />outdoors and not In attics, soffits, ridge vents or tawl spaces. <br />SITE & BUILDING INFORMATION: <br />LOT COVERAGE: <br />- LOT AREA: 9147 PIZ <br />- BUILDING FOOTPRINT: <br />(E) HOUSE: 1006 FT2 <br />(E) RACK PORCH: 377 FT2 <br />(E) GARAGE: 54S FT2 <br />- MAX LOT COVERAGE: 35% X 9147= 3201FF2 (1303 LEFT) <br />- NO NEW LOT COVERAGE <br />BUILDING HEIGHT: <br />- ALLOWABLE HEIGHT: 28'. 0' +5' - 0" (PITCHED ROOF) <br />i GART <br />I� I <br />8Snnnn22 R <br />VEJUL 3 0 2024DCITY OF EVERETT <br />Permit Services <br />----------------- <br />FSIDE SETBACK <br />IrJm AREA+FWOBB <br />°mi..,...:,ow.o. I <br />5'SIDE SETBACK <br />qm <br />APPROVED <br />Office of Community, Planning& Economic DeveloPment <br />PLANNING DEPARTMENT <br />ECEU V E <br />MAY 0 6 2024ITY OF EVERETT <br />Permit Services Mw" <br />Z <br />u <br />u� <br />LL <br />IT—A1� <br />11 <br />9 F <br />1 i <br />Bm. <br />rAavanox. <br />v/aPoas <br />m oxrm <br />JOB No. <br />m.: <br />sas <br />This property is deemed historic and sub <br />to special regulations. Any changes to apprplans shall be rea,awed by Planning. Co <br />NAME:�j�DATE: —42$-257-Ar <br />se <br />1.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.