Laserfiche WebLink
TFP220 <br />Page 7 of 8 <br />P/N 51 - <br />XXX -X <br />-XXX <br />SIN <br />SPRINKLER <br />FINISH1 <br />TEMPERATURE <br />RATING <br />135°F (57°C) <br />893 11.2K Pendent TY5237 1 NATURAL BRASS 135 <br />894 11.2K Upright TY5137 <br />4 <br />SIGNAL WHITE <br />(RAL9003) <br />155 <br />155°F (68°C) <br />POLYESTER <br />895 14.OK Pendent TY6237 <br />5 <br />JET BLACK (RAL9005) <br />POLYESTER <br />175 <br />175°F (79°C) <br />896 14.OK Upright TY6137 <br />200 <br />200°F (93°C) <br />7 <br />LEAD COATED <br />286°F (141°C <br />) <br />scu 1. E <br />Escutcheon ordered separately. <br />2. OPEN indicates the sprinkler assembly <br />9 <br />CHROME -PLATED <br />286 <br />OPEN2 <br />without glass bulb, button, and sealing <br />assembly. <br />000 <br />TABLE E <br />SERIES EC-11 AND EC-14 UPRIGHT AND PENDENT SPRINKLERS <br />PART NUMBER SELECTION <br />Care and <br />Maintenance <br />TYCO Series EC-11 and EC-14 <br />Extended Coverage Upright and <br />Pendent Sprinklers must be maintained <br />and serviced in accordance with this <br />section. <br />Before closing a fire protection system <br />main control valve for maintenance <br />work on the fire protection system <br />that it controls, obtain permission to <br />shut down the affected fire protection <br />systems from the proper authorities <br />and notify all personnel who may be <br />affected by this action. <br />Sprinklers which are found to be <br />leaking or exhibiting visible signs of <br />corrosion must be replaced. <br />Automatic sprinklers must never be <br />painted, plated, coated, or other- <br />wise altered after leaving the factory. <br />Modified sprinklers must be replaced. <br />Sprinklers that have been exposed to <br />corrosive products of combustion, but <br />have not operated, should be replaced <br />if they cannot be completely cleaned <br />by wiping the sprinkler with a cloth or <br />by brushing it with a soft bristle brush. <br />Care must be exercised to avoid <br />damage to the sprinklers before, <br />during, and after installation. Sprin- <br />klers damaged by dropping, striking, <br />wrench twist/slippage, or the like, must <br />be replaced. Also, replace any sprinkler <br />that has a cracked bulb or that has lost <br />liquid from its bulb. Refer to the Instal- <br />lation section, for more information. <br />Frequent visual inspections are rec- <br />ommended to be initially performed <br />for corrosion resistant coated sprin- <br />klers, after the installation has been <br />completed, to verify the integrity of the <br />corrosion resistant coating. Thereafter, <br />annual inspections per NFPA 25 should <br />suffice; however, instead of inspecting <br />from the floor level, a random sampling <br />of close-up visual inspections should <br />be made, so as to better determine the <br />exact sprinkler condition and the long <br />term integrity of the corrosion resistant <br />coating, as it may be affected by the <br />corrosive conditions present. <br />The owner is responsible for the <br />inspection, testing, and maintenance <br />of their fire protection system and <br />devices in compliance with this doc- <br />ument, as well as with the applicable <br />standards recognized by the Approval <br />agency, such as NFPA 25, in addition to <br />the standards of any authorities having <br />jurisdiction. Contact the installing con- <br />tractor or product manufacturer with <br />any questions. <br />Automatic sprinkler systems are rec- <br />ommended to be inspected, tested, <br />and maintained by a qualified Inspec- <br />tion Service in accordance with local <br />requirements and/or national codes. <br />Limited <br />Warranty <br />For warranty terms and conditions, visit <br />www.tyco-fire.com. <br />Ordering <br />Procedure <br />Contact your local distributor for <br />availability. When placing an order, <br />indicate the full product name and Part <br />Number (P/N). <br />Sprinkler Assemblies with <br />NPT Thread Connections <br />Specify: Series EC-11 or EC-14 <br />(specify) Sprinkler, SIN (specify), <br />(specify) K-factor, Pendent or Upright <br />(specify) Extended Coverage, (specify) <br />temperature rating, (specify) finish, P/N <br />(from Table E) <br />Recessed Escutcheon, Two -Piece <br />Specify: Style (30 or 40) Two -Piece <br />Recessed Escutcheon with (specify) <br />finish, P/N (specify*) <br />*Refer to Technical Data Sheet TFP770 <br />Flush Escutcheon, Two -Piece <br />Specify: Style 60 Two -Piece Flush <br />Escutcheon with (specify) finish, P/N <br />(specify"*) <br />**Refer to Technical Data Sheet TFP778 <br />Sprinkler Wrenches <br />Specify: W-Type 3 Sprinkler Wrench, <br />P/N 56-895-1-001 <br />Specify: W-Type 22 Recessed Sprinkler <br />Wrench, P/N 56-665-7-001 <br />