Permit #: B2402-064, Revision After Issued - First Building Review <br /> June 20, 2024 <br /> a) (IRC R314.3) Please provide a smoke alarm in each sleeping room. <br /> b) (IRC R314.3) Please provide a smoke alarm outside the bedrooms in the IMMEDIATE VICINITY.Also <br /> please avoid placing a smoke alarm within 3 feet of a bathroom door. <br /> c) (IRC R314.3) Please provide a smoke alarm on each floor(including basement) <br /> d) (IRC R314.4) Smoke alarms should be interconnected.As an option, smoke alarms may be wirelessly <br /> interconnected with a UL 217 listed wireless alarm where all alarms will sound if one alarm is <br /> activated. <br /> e) (IRC R314.6) Please ensure that smoke alarms have a battery backup. Battery powered smoke <br /> alarms are permitted for alterations, repairs, and additions per R314.6 Exception 2. <br /> 6. (IRC R315.2.2) Existing dwellings must also meet the same requirement for carbon monoxide alarm as <br /> new construction. <br /> R315.2.2 Alterations, Repairs, and Additions <br /> Existing dwellings shall be equipped with carbon monoxide alarms in accordance <br /> with Section R315.2.1. An inspection will occur where alterations, repairs, or <br /> additions requiring a permit occur, or where one or more sleeping rooms are added <br /> or created. <br /> a) (IRC R315.3) Please provide a carbon monoxide alarm in the IMMEDIATE VICINITY each sleeping <br /> area. <br /> b) (IRC R314.3) Please provide a carbon monoxide alarm on each floor(including basement). <br /> c) (IRC R315.5) All carbon monoxide alarms must be interconnected where if one alarm sounds all <br /> alarms will activate. Carbon monoxide alarms that are wirelessly interconnected and UL 2045 listed <br /> would meet this requirement, as an option. <br /> d) (IRC R315.6) Please ensure that carbon monoxide alarms have a battery backup. Battery powered <br /> carbon monoxide alarms are permitted for alterations, repairs, and additions per R315.6 Exception <br /> 2. <br /> 7. (IRC R315.4) Combination carbon monoxide and smoke alarms are allowed so long as they are listed in <br /> accordance with UL 217 and UL 2034. <br /> 8. (IRC R317) Please provide pressure-treated wood framing members that rest on concrete. <br /> 9. (IRC M1505.4.3) Please provide a 100-cfm exhaust fan for the kitchen hood, and a 50-cfm exhaust fan <br /> for each bathroom per Table M1505.4.3(3). <br /> 10. (WSEC-R R402) Please provide R-21 insulation in all exterior walls where insulation has been removed. <br /> Please provide R-49 insulation in all exposed attic spaces. <br /> Structural (Reviewer: Cal Bearman) <br /> 11. Details for the construction of the new walls should be included. The details should specify connections <br /> for the top and bottom framing plates to the existing structure. See IRC Sections R106.1.1 and R301.1. <br /> 12. The project may involve structural modifications that do not comply with the prescriptive limitations of <br /> the IRC.The new ceiling/roof framing shown as "ccg joists" on the re-submitted plans is located below <br /> where the porch roof framing bears on the home roof framing. It was unclear to the inspection team <br /> what the intent was of the additional framing at this location as it appeared to be intended to help <br /> support the un-permitted porch roof. Please address the covered back porch per item 1 of this letter. <br /> This review has been performed for general compliance with the building codes as adopted and amended by <br /> the state of Washington and the city of Everett. Corrections and comments made during the review process <br /> 3200 Cedar Street © 425.257.8810 O permitservices@everettwa.gov <br /> Everett,WA 98201 425.257.8857 fax everettwa.gov/permits <br /> Page 4 of 5 <br />