Laserfiche WebLink
WrDAIKIPI Submittal Data Sheet <br /> BRC1E73 - Navigation Remote Controller <br /> Project Name: <br /> Location: Approval: <br /> Engineer: Date: <br /> Submitted to: Construction: <br /> Submitted by: Unit#: <br /> Reference: Drawing#: <br /> Model Compatibility: <br /> For use with the following VRV indoor unit models: FXAQ, FXDQ, FXEQ, FXFQ, FXHQ, <br /> FXLQ FXMQ, FXMQ_MF, FXNQ, FXTQ, FXUQ, FXZQ <br /> For use with the following Daikin SkyAir indoor unit: models: FAQ FBQ FCQ FHQ, FTQ Cccl y CI`` <br /> 74F <br /> f <br /> S eci ications: <br /> p Product Image: <br /> Model BRC1E73 <br /> — <br /> Description Navigation Remote Controller 1 of 3 display options <br /> Detailed display shown <br /> Maximum Connections 16 indoor units <br /> Communication Wire 18AWG-2,No polarity <br /> Stranded,Non-shielded ,\ • <br /> Total Wiring Length 1,640 ft.(500 m) <br /> Communication Protocol Daikin Proprietary P1P2 protocol <br /> Power 16VDC supplied by Indoor unit <br /> (1.58VA maximum) Dimensions: <br /> Comfort Setpoint Range 60 to 90°F(16 to 32°C) <br /> —7 <br /> Setback Setpoint Range 40 to 95°F(5 to 35°C) <br /> Operating Temp Range 14 to 122°F(-10 to 50°C) <br /> 4-3/4'i <br /> Operating Humidity Range 75%or less(RH) <br /> (w/o condensation) , <br /> Dimensions(WxHxD) 4.72x4.72x0.75 inch(120x120x19 mm) <br /> Weight(Mass) 0.42 lbs. (0.19 kg) 4 3/4" a�" <br /> Features/Benefits: Group Control: Dill-Net <br /> 1. Up to 16 indoor units are controllable within one group / // <br /> 2. Within one group, up to 2 Navigation Remote <br /> Controllers can be used, one as a main and one • I <br /> as a sub p1p2 <br /> _1\ Up to 16 <br /> 3. Backlit LCD displays in English, Spanish or French indoor <br /> 4. Temperature sensor built-in with configurable offset units - 3 :i: <br /> 5. Display of Temperature and Setpoint in 1°F/°C Main Sub <br /> increments Multiple indoor units Stand-alone 2 controllers <br /> 6. Three configurable display options: Detailed, Standard group control group control used for single <br /> group control <br /> and Simple <br /> 7. Dual setpoints(independent cooling and heating setpoints) with <br /> configurable minimum setpoint differential or Single Setpoint <br /> (occupied period) <br /> 8. Setpoint range limit for cooling and heating modes <br /> 9. Independent cooling and heating setback setpoints (unoccupied period) <br /> 10. Auto changeover control with configurable Primary changeover at setpoint ±1° F with guard timer <br /> Daikin North America LLC,5151 San Felipe Suite 500,Houston,TX 77056 <br /> Daikin North America LLC Controls Engineering Department Generated Submittal Data www.daikinac.com <br /> (Daikin's products are subject to continuous improvements.Daikin reserves the right to nodify product design,specifications and information in this data sheet,ithout notice and without incurring any obligations) <br />