VDAIKIPJ Submittal Data Sheet <br /> BRC1 E73 - Navigation Remote Controller <br /> Project Name: <br /> Location: Approval: <br /> Engineer: Date: <br /> Submitted to: Construction: <br /> Submitted by: Unit#: <br /> Reference: Drawing#: <br /> 11. Airflow—Individual air flow direction, dual airflow and auto draft prevention (prevents air blowing directly <br /> on occupants)* <br /> 12. Built-in 7, 5+2, 5+1+1 and 1 (Everyday) schedules with up to 5 actions per day with independent cooling and <br /> heating or setback setpoints <br /> 13. Automatic Setback by occupancy sensor* <br /> 14. Automatic Off by occupancy sensor* <br /> 15. Configuration for Self-cleaning filter panel** <br /> 16. Automatic adjustment for Daylight Savings Time (DST) <br /> 17. 48 hour clock/calendar battery backup (protects schedule timing in cases of short term power loss from <br /> indoor unit) <br /> 18. Real-time monitoring of system malfunctions with immediate display of unit in error and error code <br /> 19. The buttons on the remote controller are selectable by locking out the unwanted buttons <br /> 20. The operation modes can be restricted to provide only the desired mode(s) of operation <br /> 21. Display can be configured to show "Off" and room temperature only when indoor unit is turned off <br /> 22. To prevent unwanted changes,fan speed selection and display may be hidden <br /> 23. Auto off timer configurable in 10 minute increments (range 30-180 minutes) <br /> 24. Can be used to replace earlier versions of remote controllers <br /> *Available for FXFQ_TVJU and FXUQ_PVJU indoor units <br /> **Available for FXTQ_TVJU indoor units <br /> Auto changeover: <br /> Automatic changeover is available for Heat Pump system and Heat Recovery systems. The setpoint for cooling <br /> and heating are configurable with a minimum differential of 0 to 7°F or single setpoint. The changeover is <br /> automatically controlled to happen in either of the following two cases: <br /> Case 1: Changeover at the primary changeover temperature after the guard timer expires. <br /> 1. In default,the primary changeover setpoint is 1°F above cooling setpoint or 1°F below heating setpoint, <br /> which is configurable between 1°F—4°F. <br /> 2. In default,the guard timer is 60 minutes, which is selectable among 15, 30,60(default) or 90 minutes. <br /> 3. The initiation of guard timer is built in to help prevent frequent changeover which may cause energy <br /> loss. <br /> Case 2: Changeover at the secondary changeover temperature. <br /> 1. In default,the secondary changeover temperature is 1°F above the primary changeover temperature for <br /> cooling or 1°F below the primary changeover temperature for heating, which is configurable between <br /> 1°F—4°F. <br /> 2. Case 2 will happen while the guard time is active in case 1. <br /> Daikin North America LLC,5151 San Felipe Suite 500,Houston,TX 77056 <br /> Daikin North America LLC Controls Engineering Department Generated Submittal Data www.daikinac.com <br /> (Dalkin's products are subject to continuous Improvements.Dalkin reserves the right to modify product design.specificalons and Information in this data sheet.,ithout notice and without incurring any obligations) <br />