My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3810 RIVERFRONT BLVD BLDG B 2025-07-15
>
Address Records
>
RIVERFRONT BLVD
>
3810
>
BLDG B
>
3810 RIVERFRONT BLVD BLDG B 2025-07-15
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/15/2025 11:49:25 AM
Creation date
6/2/2025 7:34:14 AM
Metadata
Fields
Template:
Address Document
Street Name
RIVERFRONT BLVD
Street Number
3810
Tenant Name
BLDG B
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
102
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
,A. i <br /> Air Handling Unit <br /> PROJECT: Everett Riverfront DATE: 9/18/2023 <br /> LOCATION: Everett,WA CONTACT: Sachia Keely <br /> PROJECT#: 23-0206 AUTHOR: Adam Hoskins <br /> SYSTEM/UNIT: DOAS-01 South Tested By: Mike Grim <br /> Date: 9/14/2023 <br /> �. . Motor Data <br /> Location Roof DOAS-01 South/Exhaust Fan <br /> Service South end 2-6 corridors Motor Manufacturer WEG <br /> Unit Manufacturer Aaon Motor HP 1 HP <br /> Unit Model Number RQ-003-3-V-E609-000 Motor RPM 1760 RPM <br /> Unit Serial Number 202205-AYCCO5330 Motor Frame 143/5T <br /> Type/Class FC/1 Motor Rated Volts 460 Volts <br /> Motor Phase 3 <br /> • Motor Hertz 60 Hz <br /> 7TSP <br /> Exhaust Fan Motor FL Amps 1.51 Amps <br /> —1.62 in.wc. Motor Service Factor 1.15 <br /> P 0.24 in.wc. DOAS-01 South/Supply Fan <br /> 1.86 in.wc. Motor Manufacturer Aaon <br /> Motor HP 1 HP <br /> Electrical Test Data Motor RPM 1750 RPM <br /> DOAS-01 South/Exhaust Fan Motor Frame 56Z <br /> Motor Volts 1 489 Volts Motor Rated Volts 208-230/460 Volts <br /> Motor Volts 2 489 Volts Motor Phase 3 <br /> Motor Volts 3 489 Volts Motor Hertz 60 Hz <br /> Motor Amps 1 1.4 Amps Motor FL Amps 3.4-3.2/1.6 Amps <br /> Motor Amps 2 1.4 Amps Motor Service Factor 1.15 <br /> Motor Amps 3 1.4 Amps VFD Make/Model Yaskawa <br /> Calculated FLA 1.4 FLA <br /> DOAS-01 South/Supply Fan Sheave Data <br /> Final Operating Hz 45.6 Hz DOAS-01 South/Exhaust Fan Motor Ean <br /> Motor Volts 1 312.6 Volts Drive Type Belt Belt <br /> Motor Volts 2 312.7 Volts Model 1 VP50 AK49 <br /> Motor Volts 3 312.5 Volts Bore Size 7/8 in. 1 in. <br /> Motor Amps 1 1.08 Amps Sheave position Maximum <br /> Motor Amps 2 1.09 Amps Motor Adjustment 1/3 in. <br /> Motor Amps 3 1.08 Amps Number of Belts 1 <br /> Calculated FLA -1.3 FLA Belt Size A42 or 41-440 <br /> Center Line 14 3/4 In. <br /> DOAS-01 South/Summly Fan Motor Fan <br /> Drive Type Direct Drive Direct Drive <br /> Model <br /> Bore Size <br /> Sheave position <br /> Motor Adjustment <br /> Number of Belts <br /> Belt Size <br /> Center Line <br /> Air Test Data <br /> Des Actual <br /> Supply Airflow 700 CFM 718 CFM <br /> Total Outlet Airflow 700 CFM 718 CFM <br /> Return Airflow 700 CFM <br /> Filter D. . <br /> DOAS-01 South/SF Filter Bank <br /> Filter Manufacturer Glasfloss <br /> Airtest Co. LLC <br /> Preliminary TAB Report <br />
The URL can be used to link to this page
Your browser does not support the video tag.