Laserfiche WebLink
II <br /> Sage Homes Northw1-I III C <br /> 3618 W Mukilteo Blvd, Everett <br /> 3620 W Mukilteo Blvd, Everett <br /> 3702 W Mukilteo Blvd, Everett <br /> B2304-033 through -052, First Building Review <br /> d. One copy of the geotechnical report (if applicable). <br /> Submittal documents should contain sufficient information and detail to review the proposed project <br /> for compliance with the adopted building codes. Upon submittal of the revised documents, your <br /> application will be given priority and the review will recommence. <br /> The same comments apply to the building permit applications below: <br /> 3618 W Mukilteo Blvd Unit A-E, B2304-033 through -037 <br /> 3620 W Mukilteo Blvd Unit A-H, B2304-038 through -045 <br /> 3702 W Mukilteo Blvd Unit A-G, B2304-046 through -052 <br /> Architectural <br /> (Comments provided by Tony Lee, TLEE@EVERETTWA.GOV) <br /> 1. Details should be provided that show the continuity of the one-hour rated common wall <br /> from the foundation through the floor ceiling assemblies, to the underside of the roof <br /> sheathing. IRC Section R302.2.3 <br /> 2. The common walls require parapets per IRC Section R302.2.4. The parapets (or alternative <br /> construction) requirements and details should be shown on the plans. <br /> 3. The locations where through-penetration fire-stopping in the party walls are required and <br /> the listed fire-stops proposed should be provided on the plans. Section R302.4.1 <br /> 4. The single step down from the entry porch to grade should be shown as a maximum of 7- <br /> 3/4". Section R311.7.5.1 <br /> 5. The details of the exterior guards should be shown on the plans to include minimum height, <br /> maximum opening sizes and structural attachments. IRC Section R312.1 <br /> Energy &Whole House Ventilation <br /> (Comments provided by Darren Chang, DCHANG@EVERETTWA.GOV) <br /> 6. Please show the location and efficiency of the mini-split heat pump outdoor unit. <br /> 7. The application is seeking 0.5 credit through high efficiency fan. The qualifying ventilation <br /> system and its control sequence of operation need to be shown. Table 406.3. <br /> 8. The application is seeking 2.0 credit through ductless split system heat pumps with no <br /> electric resistance heating in the primary living areas. To qualify to claim this credit, the <br /> building permit drawings shall specify the option being selected, the heated floor area <br /> O 3200 Cedar Street 0 425.257.8810 �j permitservices@everettwa.gov <br /> Everett,WA 98201 425.257.8857 fax J everettwa.gov/permits <br /> Page 2 of 3 <br />