Laserfiche WebLink
WRITTEN DIMENSIONS ON THI5 DRAWING SHALL HAVE PRECEDENCE <br />CONTRACTOR SHALL VERIFY ALL DIMENSIONS, CONDITION5, <br />BEFORE PROCEEDING. THE 0— N— BE NOTIFIED OF <br />DIMENSIONS AND/OR CONDITIONS SHOWN ON THESE DRAWINGS. <br />ACCEPT FULL RESPONSIBILItt F02 THE COST TO RECTIFY <br />OVER SCALED DIMENSIONS. <br />ETC. PERTAINING TO THE WORK <br />ANY VARIATIONS PROM THE <br />ANY SUCH VARIATION SHALL BE <br />aR THE CONTRACTOR 5HALL <br />SAME. <br />5) 12' MOIST STOP <br />FLASHING <br />I) ELECTRICAL JUNCTION BOX <br />8) WATERBLOLK 25 MIL W 12" MOIST STOP <br />WATE�ROOF FLASHING FLASHING <br />4) 1 LAYER 60 MINUTE BUILDING <br />21 QUILKFL45H ELECTRIC <br />MEMBRANE TO SEAL HEAD <br />RASNIING <br />PAPER OVER FLASHING PANEL <br />FLASHING PANE_ <br />I LAYER 60 MINUTE BUILDING IJUMBO TEX BUILDING <br />1) GI ILKFLASH PLI.FEING <br />TO CREATE SHINGLE EFFECT <br />PAPER ON TOP OF FLASHING PAPER BEHIND <br />T) WATERBLOCK 25 MIL <br />FLASHING PANE. <br />5) INSTALL VINYL BALK <br />FLA5HING <br />WATERPROOF FLASHING <br />MEMBRANE TO `SEAL .IAMB <br />5) I LAYER 60 MINUTE <br />COLUMN OR WALL FRAMING SIDING <br />NOTES: FLASHING 1 <br />BUILDING PAPER OVER FLASHING <br />I) METAL FLASHIN65 <br />PANEL TO CREATE SHINGLE <br />FETAL WATERTABLB51LL <br />FLASHING 51DIN6 <br />f <br />AT TOP BETY�TN TRIM <br />AND DOOR <br />EFFECT <br />O <br />2) NO CAULKING STAPLE ONLY THIS AREA I" X <br />4) INSTALL KID VINYL <br />PREDRILL <br />BETYm DOOR FRAME WIDTH OF DOOR <br />BOCK SUPPORT WITH <br />AND TRIM <br />BEVELED EDGE <br />5) CAULK AT 51DINS 1) 12" WATERBLOLK NAIL ON <br />AND TRIM ONLY FLASHING <br />O <br />2X WOOD TRIM G)i AT <br />4) DOOR TRIM TO BE <br />2° BACK BEVEL OR <br />SAX UNLE55 NOTED 5) I LAYER 60 MINUTE <br />�2) <br />STOPS LEDGE TED. <br />FIELD VERIFY DETAIL <br />OTHERWISE BUILDING PAPER STOP PAPER <br />© <br />I LAYER 60 MINUTE <br />BUILDING PAPER UNDERNEATH <br />5) 1 LAYER 60 MINUTE <br />(WOOD <br />5) DECK APPLICATION <br />SEE TYPICAL DETAIL 4) SLIDING GLASS DOOR AT DOOR FLANGE AT TOP AND <br />SIDES OF DOOR RUN PAPER <br />PREDRILL <br />BOTTOM 51PE OF FLA5HIN6 PANEL <br />BUILDING PAPER UNDERNEATH <br />BOTTOM SIDE OF FLASHING PANS <br />WOOD DETAIL <br />FXD200 CAULKIBEHIND DOOR FLANGE UNDER FLANGE AT BOTTOM OF <br />5) PLUMBER INSTALL FROST <br />6) INSTALL SIDING <br />WOOD DETAIL <br />LAYER 60 MINUTE <br />DOOR <br />6) MTERBLOCK 25 MIL AT TOP AND 51DF5 (SECURE <br />WATERPROOF FLA514I145 DOOR WITH NAILS PER <br />FREE HvSE BIB <br />BUILDING PAPER <br />MEMBRAPE OVER DOOR MANUFACTURERS SPECS) <br />BEHIND FLASHING <br />FLANGE AND HOLD BACK <br />FROM DOOR FRAME <br />O ELECTRICAL BOX FLASHING PANEL <br />FLASHING v0NOOD SIDING <br />ON A <br />O DING GLASS DOOR <br />LUUMBING FLASHING PANEL <br />O <br />EERTABLE/SILL <br />NO SCALE <br />LE <br />P <br />2) MOIST STOP FLASHING <br />2) MOIST STOP <br />VINYL BLOCK <br />FLASHING <br />2) QUICK PLA54 <br />PLUMBING FLA5HING <br />K LOCK <br />4) 1 LAYER 60 MINUTE <br />PANEL <br />5) MOIST STOP PLASM <br />5 <br />2 5 <br />2MIL <br />BUILDING PAPER OVER <br />FLASHING PANEL TO <br />CREATE SHINGLE EFFECT <br />2) 26 GAL.. SHEET METAL VENT <br />5Ki PAPER <br />KATERPROOF <br />FLASHING ) WATERBLOGK 25 MIL <br />��� WATERPROOF FLASHING <br />TO SEAL MEMBRANE TO SEAL <br />WINDOW <br />\ ROUGH <br />OPENING <br />IN <br />COVER INCLUDING CAULK BENiIND FLANGE <br />.IAMB FLASHING <br />5) VINYL BLOCK <br />AT TOP AND SIDES (SECURE VENT COVER <br />DOOR <br />HEAD <br />WITH NAILS) <br />OPENING <br />PLASHING <br />U PIPE OR WIRE <br />2-- <br />\ <br />PENETTRR�ArTIOONN <br />y\0 O <br />1) 12' WATERBLOLK <br />NAIL ON FLA5HIN5 <br />- <br />\ \\ <br />- `STAPLE ONLY THIS AREA I" X <br />PREDRILL <br />SLOPE TO DRAIN <br />NOTES: <br />- WIDTH OF WINDOW <br />V <br />I) 2 METAL <br />BE <br />AT TOP WM TRIM <br />1) 12" WATERBLOGK <br />R <br />0 <br />AND WINDOW <br />NAIL ON FLASHING <br />V.I.. <br />NO <br />CAULKING O N 2) PLKING <br />BWINDOW <br />— <br />I) MOIST STOP <br />FRAME AND TRIM <br />FLAMING <br />5) CAULK AT 51DIN6 <br />AND TRIM ONLY <br />4) LAYER 60 MINUTE <br />BUILDING PAPER STOP <br />4) WNDOW TRIM TO BE <br />PAPER AT WINDOW <br />5/4 <br />FLANGE AT TOP ANDSIDES <br />5) LAYER 60 MINUTE <br />II/Ib" <br />OF WINDOW. RUN <br />BUILDING PAPER <br />PAPER ENDER <br />6) INSTALL SIDING <br />UNDERNEATH BOTTOM 51DE <br />5) WATERBLOGK 25 MIL <br />5) WINDOW INCLUDING FLASHING AT BOTTOM <br />OF FLASHING PANEL <br />WATERPROOF FLASHING <br />POLYURETHANE CAULK OF WINDOW <br />5) DRILL HOLE FOR PIPE <br />4) WATERNII 25 MIL 5) 1 LAYER 60 MINUTE BUILDING PAPER <br />MEMBRANE OVER <br />BEHIND WINDOW FLANGE <br />WATERPROOF FLASHING STOP PAPER NG FLANGE AT TOP AND <br />MEMBRANE OVER FLANGE AND SIDES OF FLANGE. RUN PAPER UNDER <br />4) INSTALL DOOR 5) FETAL Z FLASHING AT <br />WINDOW FLANGE AND <br />HOLD BACK i' FROM <br />AT TOP AND 51DM <br />(SECURE WINDOW WITH <br />HOLD BACK }' FROM VENT COVER YNATERBLOCK NAIL ON FLASHING AT <br />HEAD. I LAYER 60 MINUTE <br />WINDOW FRAME <br />NAILS PER <br />BOTTOMOF VENT LOVER <br />BUILDING PAPER <br />MANIFACTLRER5 <br />SPECS) <br />OPLUUMBING/WIRE FLASHING PANELS <br />O VENT COVER FLASHING <br />NINOING DOOR <br />� <br />WW NDOFLASHING <br />NO SCALE <br />NO WALE <br />SCALE <br />O <br />O N <br />ROOFING MATERIAL <br />2xn BLOCKING <br />24" GARDBOARD BAFFLE FIN15H PER ELEVATION <br />ALLOW FOR I' AIR 5PAGE SHEATHING AND TRV55 5PE65 <br />MIN. EXTEND 12' ABOVE PER 5TRUCTIRAL DRANING5 <br />INSULATION. <br />HANDRAIL: <br />BEAM <br />GRIP 144" - 2" m <br />PER PLR <br />PROJECTION FROM <br />NO5IN6 <br />z <br />POST GAP FT <br />WALL NO LE55 <br />f <br />PER PLAN <br />THAN Yz". <br />Z_v <br />PT PO5T <br />AT COLUMN <br />2" BUTTON VENT (TYP.) <br />O <br />OPEN RAIL: <br />CORNER <br />SHEATHING <br />SIDING <br />OPEN SPACE BETWEEN <br />I LAYER 60 <br />MINUTE <br />MINUTE <br />LAYER 60 MINIMS <br />PICKETS SHALL BE <br />LE55 THAN 4" CLEAR = <br />m <br />/ <br />METAL TOP PL. <br />PAPER <br />BUILDING PAPER - <br />j1� <br />STAIR NOTES: <br />6U ER <br />i <br />F '0 <br />RISER HEIGHT = "I-3/4" MAX. <br />7 I✓ <br />TREAD DEPTH = 10" MIN, m <br />i <br />APPROVED TRu55E5 BEARING <br />MANUFAGTURER55EAL <br />2X4 FRAME <br />(OPTIONAL PT <br />SEALANT (I / <br />- 6° <br />�I <br />Y <br />HANGER <br />SEE ROOF FRAMING PLAN <br />FOR 5FAGIN6 <br />MATERIAL) <br />_ IIO° <br />2X4 STOP <br />3-2X12 <br />VENTED BIRD BLOCKING <br />\ <br />STRINGER5 <br />WHERE OVERHANG 15 NOT <br />WATER TIGHT <br />`� <br />2-2X HEADER <br />WITHIN 5' 55BL AREAS 1/2" 6WB AT CEILINGS <br />-I/16" OBB SHEATHING <br />DIVERTER -�� <br />eSEAMS (ma) ., ( <br />I <br />i IIO\ <br />1 �° <br />FLOOR JOIST <br />2X4 BLOCKING Z <br />(FIRE57-OP) F <br />SOLID BLOCKING IF <br />OVERHAN6 15 R-21 AT EXTERIOR NALL5 <br />WITHIN 5' B5BL AREAS AND RE5IDENGE/GARAGE WALL5 <br />WITH HARDIE-PANEL <br />APPLIED OVER. CORNERS <br />PER ARCHITECTURAL PLANS <br />FIREBLOGK STAIRS: <br />CAULK AND SEAL ALL JOINTS <br />GUT FASCIA J <br />ONCE IN TOP I BOTTOM � <br />FIREBLOGKS � <br />2X6 5TUD5 L �/ NG AREA <br />TIGHT <br />APPROX. 2' i <br />TO ALLOW <br />OF RUN BETWEEN 5TRIN6ER5 \ <br />KICKOUf PLASHING <br />I ALONG RUN BETWEEN STUDS <br />FOR <br />CONTINUOUS <br />5HEATMNG PER 5TRUGTURAL <br />INSTALLATION <br />USABLE SPACE UNDER 5TAIR5 <br />DRAWINGS <br />GONNEGTION <br />2" BUTTON VENT (TYR.) <br />OP WB AND <br />TO BE I HR FIRE CONSTRUCTION <br />PER FOUNDATI O <br />SIDING <br />NOTE; <br />TWO LAYERS <br />R <br />SIDING PER ELEVATION 1/2" 6NB AT WALLS <br />PLAN <br />"GAP AT BOTTOM <br />5urrez Nor SHora FOR cLAwTY <br />AT85TTA CEILING) <br />2X4 PT PLATES <br />AT CONCRETE <br />O�C.KOUT FLASHING <br />NO <br />TYPCAL STAIR DETAIL <br />II F�PIICAL WALL/ROOF DETAIL <br />12 FRONT PORCH COLUMN DETAIL <br />IO DI <br />1� <br />ir1 <br />I, -Li <br />� c <br />aS <br />U <br />z <br />w <br />� <br />� <br />Vl <br />to <br />Q <br />V <br />Wl <br />`- <br />V <br />0 <br />m <br />0 <br />L <br />Q <br />data: <br />6-I6-20 <br />permit: <br />ravtstons: <br />drawn byy <br />LMD <br />chackcad <br />by: MWJ <br />SHEE1=T <br />2 <br />ol= <br />