Laserfiche WebLink
Category 2:Sensitive information <br /> GENERAL YES NO <br /> Bathroom doors are easily and quickly openable from the outside when locked 1W 13 <br /> Carbon Monoxide alarms are Installed as required in R315 on each level of the home. Cf 13 <br /> Smoke alarms are installed on all levels of the dwelling,in each resident sleeping room,outside each separate sleeping <br /> area in the immediate vicinity of sleeping rooms(11314). IP' 13 <br /> Smoke and Carbon Monoxide alarms are installed in such a manner so that the audible warning may be heard in all <br /> parts of the dwelling upon activation of a single device. <br /> Access road and water supply meet local fire jurisdictional requirements, <br /> R330.4 Operable parts of door handles, pulls,latches,locks and other devices installed in AFH shall be operable with <br /> one hand and shall not require tight grasping,pinching or twisting of the wrist(lever-type). <br /> Pocket doors shall have graspable hardware available when in the closed or open position. ills, <br /> R311.6 Ramp YES NO <br /> Inside Ramp N/A93 13 <br /> R311.8.1 Maximum Slope one unit vertical in twelve units horizontal(8.3%slope).(Exception R311.8.1 Not allowed in AFH 0 13 <br /> R330.9) <br /> R311.8.2 Landing Requirements:min.3X3 foot landing at top/bottom,where doors open onto ramps,and where ramp <br /> changes directions. 13 0 <br /> R330.9.1 Handrails required on both sides of ramp. 0 13 <br /> Outside Ramp IN/A YES NO <br /> R311.8.1 Maximum Slope one unit vertical in twelve units horizontal(8.3%slope). (Exception R311.8.1 Not allowed in AFH 0 <br /> R330.9 <br /> R311.8.2 Landing Requirements:min.3X3 foot landing at top/bottom,where doors open onto ramps,and where ramp <br /> changes directions. 13 <br /> R330.9.1 Handrails required on both sides of ramp. <br /> R312.1.1 Guards shall be located along open-sided walking surfaces,that are located more than 30 Inches measured 191 0 <br /> vertically to the floor or grade below at any point within 36 inches horizontally to the edge of the open side. <br /> Guards below are depicted vertically as an example only. <br /> Handrail both sides <br /> Less than 4" 34"-38" <br /> Guard - - _ _ - -—----—----- ----- <br /> 36"min { - - - - <br /> FZ <br /> 3'x 3'min <br /> landing <br /> ' minx 3' <br /> ----`----------_ s <br /> landing <br /> ----3' - -One unit vertical in twelve units horizontal 3 - <br /> minimum is an 8.3%slope all along surface of the ramp. minimum <br /> Implementation Date: 2024 March 15 <br /> Updated: 2024 March <br /> Category 2:For official use only/disclosure permissible by law. <br />