Laserfiche WebLink
Scale: '/4"= 1' <br /> Name of Complex: Grandview Plaza <br /> Address: 2030 Grand Ave Everett, WA 98201 <br /> Parcel: 01092900000100 (7 parcel#s for building, entered Unit 1 for Garage) <br /> Property Manager: Stan Kuligoski <br /> Plans By: Katie Beasley- McLeod Construction <br /> Description of Work: Repair ceiling in the Garage. Replace insulation and (2)LAYERS 5/8"TYPE'X' <br /> drywall <br /> Drywall/Screw Specs <br /> will be spaced 12 inches apart on s <br /> - 7 to 8 inches apart <br /> - Screws wit east 3/8 inches from Ind edges of the drywall. <br /> - nets will be staggard so that the seams are at least 10 inc <br /> REFERENCE GA FILE NO. FC 5512(SIM) <br /> BASE PANEL INSTALLED PERPENDICULAR TO TRUSSES WITH MIN 1-1/4"TYPES'SCREWS AT 12"OC EDGE AND FIELD <br /> FACE LAYER INSTALLED PERPENDICULAR TO TRUSSES WITH MIN 1-7/8"TYPES'SCREWS AT 12"OC MIN 3"FROM <br /> EDGES. OFFSET JOINTS 24"MIN. FROM BASE LAYER. <br /> INSULATION: <br /> INSTALL R-30 TO MATCH EXISTING. INSTALL TO PROVIDE CONTINUOUS R30 THERMAL BARRIER THROUGHOUT <br /> GARAGE. REFERENCE 2021 WSEC SECTIONS C501.3 AND C402.2.3. <br /> INSULATE DUCTWORK AS REQUIRED. SEE 2021 WSEC SECTION C403.10.1,TABLE C403.10.1.1. <br /> M ev rr City of Everett Permit Services <br /> F C <br /> o m GI REVIEWED FOR CODE COMPLIANCE <br /> By Review Discipline: Building <br /> �0 n Reviewer: SSchreffler <br /> (D Date: 12/16/2024 <br /> o, Review Status: Approved for Permit <br /> (D M <br /> Q < <br /> o CD <br /> m <br /> (D <br /> 3 CD <br /> N rt <br /> O CD <br /> N <br /> O n' <br /> CD <br /> to <br />