My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1215 80TH ST SW 100 2023 Plans 2025-07-01
>
Address Records
>
80TH ST SW
>
1215
>
Plans
>
1215 80TH ST SW 100 2023 Plans 2025-07-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/4/2025 9:06:06 AM
Creation date
6/4/2025 9:05:32 AM
Metadata
Fields
Template:
Address Document
Street Name
80TH ST SW
Street Number
1215
Unit
100
Permit
B2312-008
Year
2023
Notes
1ST FLOOR 2,513 SF OFFICE AREA, CONF. & BREAK RMS, RESTROOMS
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
R-21 BATE INSULATION ABOVE EXISTING 2"x 4 <br /> TO HAVE WHITE VAPOR BARRIER vv 13/q" 1/2"THERMALLY N <br /> w/MAX.FLAME SPREAD RATING v2" BROKEN ANODIZED 71 <br /> OF 25 AND SMOKE DEVELOPED ALUMINUM WINDOW $ <br /> RATING OF 450.ttP.ABOVE SYSTEM W/1" <br /> WALL FURRING. INSULATED TINTED <br /> EXISTING CON. GLASS <br /> PANEL METAL STUD FRAMING W/36" <br /> TYPE"X"GWB/W R-13 BATT LINE OF PANEL PROVIDE CONTINUOUS <br /> a° INSULATION BEYOND------_, CAULK BEAD BETWEEN <br /> WIDOW FRAME AND <br /> PROVIDE CONTINUOUS SILL. Ci <br /> CAULK BEAD BETWEEN u, <br /> WIDOW FRAME AND a 1 x WOOD SILL PIECE. o 0 <br /> EASE EDGES.PAINT d F <br /> PACK VOID AT TOP OF GWB. DIM.POINT <br /> FULL HEIGHT WALL WITH �— 2x TREATED WOOD a <br /> I ROCKWOOL (WIDTH OF DIM.POINT BLOCKING. °d <br /> WALL, RIGID INSULATION n d <br /> I I AND GWB. ------------------ a o <br /> ------------------------- <br /> 362S162-43 GA �i <br /> I I ZE <br /> SUSPENDED ACOUST. ° PACK VOID AT TOP z a <br /> t / SEALANT CEILING GRID h TILE METAL STUDS®24" OF FULL HEIGHT WALL <br /> O.C.W/5/8"TYPE METAL STUDS W/ WITH ROCKWOOL g <br /> EXISTING c "X"GWB W/R-13 HILTI-ENP19 PAF <br /> 10 EXISTING ANODIZED 5" (WIDTH OF WALL, <br /> TILT-UP BATT INSULATION 24" O/C <br /> TA4. LINE OF ALUMINUM WINDOW CONCRETE RIGID INSULATION AND <br /> PANEL BEYOND SYSTEM W/ 1" PANEL. 5/8" TYPE GWB ) <br /> "X" <br /> INSULATED GLASS. GWB ci <br /> OVER R-13 GATT � <br /> INSULATION ^ I` <br /> WINDOW HEAD AT STOREFRONT WINDOW SILL AT STOREFRONT EXISTING WF <br /> JOIST/STRUCTURE PER <br /> Scale: 1 1/2"=1'-0' 4 Scale: 1 1/2"=1'-0" STRUCTURAL DRAWINGS <br /> METAL STUDS W/ <br /> HILTI-ENP19 PAF ® WW <br /> 24" O/C <br /> R �fn <br /> DEFLECTION TRACK <br /> PER STRUCTURAL <br /> SECURE STUDS TO <br /> SLOTTED DEFLECTION <br /> TRACK. ATTACH G.W.B. <br /> TO STUDS ONLY (NOT <br /> DEFLECTION TRACK) <br /> WALL PER PLANS <br /> TOP OF DEMISING WALL <br /> Scale: 3" = 1'-0" <br /> NEW FULL HEIGHT V <br /> DEMISING WALL cc <br /> (WAREHOUSE TO <br /> WAREHOUSE): ,^ <br /> 5/8" TYPE '9(" GWB V/ <br /> WAREHOUSE EACH SIDE <br /> OF 6" METAL STUDS AT <br /> 16" O.C. WITH R-21 O W <br /> BATT INSULATION. FIRE STEEL- _FRAMING � U ^` <br /> TAPE ONLY. SEE 2OO-$OO E W <br /> STRUCTURAL FOR STUD ` <br /> DETAILS. O O / <br /> Q La. L7 Cz <br /> � � � <br /> The issue of connection of non-load bearing walls to Me suspension system of a lay-in acoustical ceiling has been U <br /> an issue for decades in the code enforcement section. ei/L�( co <br /> The Uniform Building Code was rather vague on the issue.The International Building Code(IBC)section 1621.1.2 is C Q tV Ln <br /> based on ASCE(American Society of Civil Engineers)standard 7-02 states: N C'V > <br /> "Partitions that are tied to the telling and all partitions that are greater than 6 feet(1829mm)in height v. Cal LLI <br /> shall be laterally braced to the building structure.Such bracing shall be independent of any ceiling splay <br /> bracing" U] Q m <br /> ut <br /> The confusion and the intent of the code may be cleared up best by the commentaries that explain ASCE 7-02.The I.I rn <br /> engineers had noticed that when touring buildings after a significant earthquake the non-load bearing walls using LLLLJ [� <br /> the suspension system as the means to brace the partition provided doubtful adequate support."Partitions must be r N <br /> ENTIRE RESTROOM CEILING ENTIRE RESTROOM CEILING braced to the building and <br /> not rely on the bracing of the ceiling suspension system for support.This does not mean Q <br /> COVERED WITH SOUND COVERED WITH SOUND that they can not be connected or"tied"together as stated in the IBC code. <br /> N _ Q <br /> WIDTH PER PLAN BATT INSULATION. WIDTH PER PLAN BATT INSULATION. 1O <br /> There is a requirement for partitions and the suspension systems to be independent of each other for seismic design U ❑ <br /> category"C"buildings.SDC"C"buildings are intended to have a"free floating"ceiling and expect limited movement. N <br /> The ceilings and partitions in SDC C buildings shall not be connected or"tied"to the suspension system.For build- 0 <br /> 1 Inge designated D,E or F,the partitions may be connected to the suspension system. N <br /> O Ul 6" METAL CEILING JOISTS 6" METAL CEILING JOISTS y SUSPENDED CEILING NOTE: N N <br /> AT 24" O.C. PER AT 24" O.C. PER 19 SYSTEM PER REFLECTED BUILDING IS SDC D. REFER TO GENERAL NOTES ON SHEET S1.0 W m <br /> STRUCTURAL STRUCTURAL TA41 CEILING PLAN Q F Q <br /> ASCE 7 13.5.8 PARTITIONS 3 <br /> 5/8"TYPE "X"GWB 5/8"TYPE "X" GWB ATTACH TOP TRACK TO LATERALLY BRACED TO STRUCTURE. _ <br /> (� <br /> 3 5/8" METAL SUSPENDED CEILING [] w <br /> STUDS ® 16" 6" METAL STUDS ® 16" MAIN RUNNER WITH TWO EXCEPTION: PARTITIONS THAT MEET ALL OF THE FOLLOWING CONDITIONS: J <br /> 1. THE PARTITION HEIGHT DOES NOT EXCEED 9 FT. i <br /> D.C. STAGGERED O.C. WITH 5/8"TYPE "X" #8 S-SCREWS 2. THE LINEAR WEIGHT OF THE PARTITION DOES NOT EXCEED THE W W uWi <br /> WITH 5/8" TYPE GWB W/ R-21 BATT PRODUCT OF 10 LB (0.479 kN) TIMES THE HEIGHT [ft (m)] OF THE V) <br /> "WR" GWG INSULATION. PROVIDE PARTITION. J J <br /> SOUND BATT INSULATION WR GWB AT WET WALLS. c 3 5/8" METAL STUDS ® 3. THE PARTITION HORIZONTAL SEISMIC LOAD DOES NOT EXCEED 5 PSF J F ❑ <br /> PAINT 1 16" O.C. WITH 5/8"TYPE (0.24 kN/mz). Q N <br /> °i "X" GWB W/ SOUND BATT W _ uj <br /> o WAREHOUSE WAREHOUSE TOILET SIDE TOILET SIDE TOILET SIDE TOILET SIDE INSULATION. Ljj ] ❑ <br /> SIDE SIDE 3 5/8" CONT. METAL m <br /> N 0 TRACK. SEE I <br /> STRUCTURAL. <br /> SEE STRUCTURAL FOR 3 5/8" CONT. METAL 6" CONT. METAL TRACK. (n W p <br /> BOTTOM TRACK DETAIL TRACK. SEE SEE STRUCTURAL. Z v L] in <br /> - AT FULL HEIGHT WALL STRUCTURAL. BASE PER m,,,,,. ",a"..." ..a"m""Ia I" ��r�. "a.aw,.,,, r�."....u.m" .k..".".,,"..o,�mo .� a ."�...��n. se <br /> se <br /> o SCHEDULE nme.� lru.mimb ". o,.i"" nwcem rm",."n.,u O Z <br /> u.mm�u. "Ierwaia.mm.e n.��inle �' <br /> LAB <br /> NC. <br /> U J Q � <br /> FLOOR S <br /> '^ " > .- .••° A IONWCB 2828 EastlakeeAve E Ste 360 1 Seattle,WA 98102 te1 E03-29E 0333 <br /> • ewwn.iaceinevuarnnu tel 206 624-4243 I is email'nfo cb.org emailOregon@nwcb org (W sheet <br /> • y2_ '• .- • � <br /> I I ice. i.,i i I i i "on"w[s•wnu a"ocnu"v euAenu <br /> J <br /> WALL SECTION H WALL SECTION WALL SECTION K WALL SECTION 9 TOP OF PARTITION WALL ATTACHMENT NOTE allTA4.1 <br /> G Scale: 1/2"=1'-0 Scale: 1/2"=1'-0" Sole: 1/2"=1'-0" Scale: 1/2"=1'-0" Scale: N.T.S. <br /> f <br />
The URL can be used to link to this page
Your browser does not support the video tag.