My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD 2024 BLDG 40-36 Plans 2025-07-01
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-36
>
Plans
>
3003 W CASINO RD 2024 BLDG 40-36 Plans 2025-07-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/4/2025 9:17:19 AM
Creation date
6/4/2025 9:17:00 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-36
Permit
M2403-041
Year
2024
Notes
TOWER RELOCATION
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GENERAL DUCTWORK AIR TERMINALS (CONTINUED) PIPING IDENTIFICATION <br /> A COMPRESSED AIR IN INCHES 24 12 SANITARY WASTE PIPING AND FITTINGS <br /> AAV AUTOMATIC AIR VENT RECTANGULAR DUCT, FIRST NUMBER EXHAUST GRILLE/REGISTER <br /> AD ACCESS DOOR KW KILOWATT 24 12 INDICATES SIZE FOR SIDE SHOWN (WALL) ❑o FED FUNNEL FLOOR DRAIN CHWS CHILLED WATER SUPPLY <br /> AFF ABOVE FINISHED FLOOR 24/12� SUPPLY AIR DUCT SHOWN IN SECTION, ARROW ❑G FD FLOOR DRAIN CHWR CHILLED WATER RETURN <br /> AP ACCESS PANEL LBS POUNDS POINTS TO SIDE CALLED OUT FIRST <br /> AHU AIR HANDLING UNIT LWT LEAVING WATER TEMPERATURE SQUARE SUPPLY AIR DIFFUSER o FCO FLOOR CLEANOUT CW CITY WATER (DOMESTIC) <br /> Al ANALOG INPUT 24/12� RETURN, EXHAUST OR OUTDOOR AIR DUCT SHOWN IN <br /> AO ANALOG OUTPUT MAX MAXIMUM SECTION, ARROW POINTS TO SIDE CALLED OUT FIRST DOOR AIR TRANSFER GRILLE — CO CLEANOUT, EXPOSED CITY WATER (DOMESTIC) <br /> A/C AIR CONDITIONING MBH THOUSAND BTU PER HOUR <br /> MECH MECHNICAL 24 ROUND DUCT, NUMBER — WOO WALL CLEANOUT A COMPRESSED AIR (100 PSIG NOMINAL) <br /> BHP BRAKE HORSEPOWER MIN MINIMUM <br /> BLDG BUILDING 2�� INDICATES DIAMETER ROOF AIR INTAKE - AHU <br /> LATERAL HW HOT WATER (DOMESTIC) <br /> BTU BRITISH THERMAL UNIT NO NOISE CRITERIA SUPPLY AIR DUCT, SQUARE OR <br /> CAP CAPACITY GENERAL PIPING — <br /> NO NORMALLY OPEN RECTAN GU LAR,ELBOW TURNING TOWARD SANITARY WYE AND 1/8 BEND HOT WATER (DOMESTIC) <br /> CFM CUBIC FEET PER MINUTE CA OUTDOOR AIR SUPPLY AIR DUCT, SQUARE OR WASTE PIPING QUARTER BEND —HWC— HOT WATER CIRCULATING (DOMESTIC) <br /> C CENTER LINE OC ON CENTERS RECTANGULAR ELBOW TURNING AWAY NEW AND EXISTING WORK - �} <br /> COL COLUMN DESIGNATED BY NOTE o WASTE PIPING BEND WITH CLLANOUT HOT WATER CIRCULATING (DOMESTIC) <br /> CONN CONNECTION POW PUMPED COLD WATER RETURN AIR DUCT, SQUARE OR + <br /> CW CITY WATER (DOMESTIC) PD PRESSURE DROP OR PRESSURE DIFFERENTIAL RECTANGULAR ELBOW TURNING TOWARD = ,y,rs EXISTING TO BE REMOVED LPS LOW PRESSURE STEAM <br /> CMU CONCRETE MANONRY UNIT PH PHASE <br /> CHI CHILLED WATER SUPPLY/RETURN PNEU PNEUMATIC RETURN AIR DUCT, SQUARE OR HIDDEN OR BELOW GRADE ROOF DRAIN PIPING C GRAVITY CONDENSATE RETURN <br /> POC POINT OF CONNECTION RECTANGULAR ELBOW TURNING AWAY <br /> DB DRY BULB PSI POUNDS PER SQUARE INCH RD ROOF DRAIN SAN SANITARY WASTE ABOVE GRADE <br /> DDC DIRECT DIGITAL CONROL PSIG PSI GUAGE ® ROUND DUCT CONNECTING LINES <br /> DISCH DISCHARGE ELBOW TURNING TOWARD O VTR VENT THROUGH ROOF SAN SANITARY WASTE BELOW GRADE <br /> DI DIGITAL INPUT RAG RETURN AIR GRILL ROUND DUCT OFD <br /> DIA DIAMETER REF REFERENCE OVERFLOW DRAIN V SANITARY VENT ABOVE GRADE <br /> D I FF DIFFERENCE PM ROOM ELBOW TURNING AWAY I CROSSING LINES, NON-CONNECTING (TOP OR <br /> DN DOWN RPM REVOLUTIONS PER MINUTE I FRONT PIPE IS SHOWN AS SOLID LINE) V SANITARY VENT BELOW GRADE <br /> DO DIGITAL OURPUT TRANSITION, RECTANGULAR TO RECTANGULAR <br /> SA SUPPLY AIR OR ROUND TO ROUND PUMP (IN - LINE) F FIRE WATER MAIN <br /> EAT ENTERING AIR TEMPERATURE SAN SANITARY (UPSTREAM OF ALARM VALVE) <br /> EFF EFFICIENCY SD SMOKE DAMPER TRANSITION, RECTANGULAR <br /> EL ELEVATION SENS SENSIBLE TO ROUND OR OVAL PUMP S FIRE SPRINKLER PIPING <br /> ELEC ELECTRICAL SP STATIC PRESSURE (DOWNSTREAM OF ALARM VALVE) <br /> EMS ENERGY MANAGEMENT SYSTEM SQ SQUARE <br /> FLEXIBLE DUCT PLUMBING FIXTURES <br /> EMCS ENERGY MANAGEMENT CONTROL SYSTEM SS STAINLESS STEEL INSULATED PIPE TEST ALARM VALVE TEST PIPING <br /> EWT ENTERING WATER TEMPTERATURE STM STEAM ❑ LWC ELECTRIC WATER COOLER <br /> EXH EXHAUST RECTANGULAR DUCT, SQUARE ELBOW PHW PUMPED HOT WATER (DOMESTIC) <br /> EXIST EXISTING TEMP TEMPERATURE WITH TURNING VANES —j t— BREAK IN PIPE (USE WHERE SECTION OF PIPING <br /> EXT EXTERNAL TYP TYPICAL IS OMITTED FROM DRAWING FOR CLARITY) 4 WC-1 WATER CLOSET PCW PUMPED CITY WATER (DOMESTIC) <br /> �—I� ACCESS DOOR (AD) OR <br /> FC FAN COIL V VOLTS AU UK Ar ACCESS PANEL (AP) DIRECTION OF FLOW PIW PUMPED INDUSTRIAL WASTE <br /> FCO FLOOR CLEANOUT VAV VARIABLE AIR VOLUME SLOPE DN URINAL <br /> ED FLOOR DRAIN VEL VELOCITY AD ACCESS DOOR DIRECTION OF SLOPE DOWN <br /> FIG FIGURE VERT VERTICAL <br /> FLR FLOOR / FLEX CONNECTION LAVATORY VALVES <br /> FPM FEET PER MINUTE W WITH LINED DUCT (DUCT DIMENSIONS ARE <br /> FT FEET WB WET BULB FOR NET FREE AREA) �I BLIND FLANGE <br /> WG WATER GAUGE ❑ SERVICE SINK ��� BALL VALVE <br /> GA GAUGE WHA WATER HAMMER ARRESTER MlEn FLEXIBLE DUCT CONNECTION CAPPED PIPE END <br /> GAL GALLON WxH WIDTH BY HEIGHT �a PLUGGED PIPE END Vl BUTTERFLY VALVE <br /> GALV GALVANIZED D4 GATE VALVE <br /> GV GROOVED JOINT WITH COUPLING #" # - INCHES DUCT OFFSET UP OR DOWN __LAAV AUTOMATIC AIR VENT <br /> GPH GALLONS PER HOUR # - FEET <br /> # C� GLOBE VALVE <br /> GPM GALLONS PER MINUTE ROUND DIAMETER <br /> GWB GYPSUM WALL BOARD F DEGREES FAHRENHEIT AIR DAMPERS PRESSURE GAUGE WITH VALVE DUCT MOUNTED EQUIPMENT <br /> PRESSURE DIFFERENCE PRESSURE DROP —DA �a ANGLE GLOBE VALVE, ELEVATION/PLAN <br /> LP / � CENTRIFUGAL FAN <br /> HOA HAND OFF AUTO VOLUME DAMPER ELBOW TURNED DOWN OR AWAY 41:�i — CHECK VALVE <br /> HP HORSE POWER i IF <br /> HR HOUR S 0 ELBOW TURNED UP OR TOWARD CENTRIFUGAL FAN, INLET GUIDE VANES SOLENOID OPERATED VALVE <br /> HWC HOT WATER CIRCULATING <br /> HZ HERTZ OPPOSED BLADE DAMPERS REDUCER, CONCENTRIC BALANCING VALVE <br /> HxW HEIGHT BY WIDTH RETURN AIR DUCT, SQUARE OR <br /> NOTE: POINT OF CONNECTION DUCT DAMPER, MOTOR OPERATED <br /> REDUCER, ECCENTRIC RECTANGULAR ELBOW TURNING TOWARD BALANCING VALVE W/ METERING PORTS <br /> � � X <br /> BLDG EL 100'-0" = SITE EL 548.33' DM (ELECTRIC OR PNEUMATIC) STRAINER X D� 2-WAY CONTROL VALVE <br /> PARALLEL BLADE DAMPER � TEE � 3-WAY CONTROL VALVE <br /> FD TEE UP INSTRUMENTATION AND CONTROL AUTOMATIC FLOW CONTROL VALVE <br /> SECTION LETTER OR DETAIL NUMBER FIRE DAMPER (NUMBER INDICATES GPM) <br /> (VERTICAL) TEE DOWN MD UD MI TEMPERATURE SENSOR, HUMIDITY SENSOR, <br /> SHEET SHOWN ON ®Fp FIRE DAMPER �T FLOAT AND THERMOSTATIC SMOKE DETECTOR, DUCT MOUNTED 'vim PLUG VALVE <br /> TRAP ASSEMBLY <br /> SHEET TAKEN FROM ® (HORIZONTAL) Z BACKFLOW PREVENTER <br /> PIPE ALIGNMENT GUIDE <br /> SECTION/DETAIL MARK THERMOSTAT DI PRESSURE REDUCING VALVE <br /> AIR TERMINALS (D WALL <br /> INLET DIAMETER EC = ELECTRIC COILS PT PLUG <br /> �^f OS & Y VALVE <br /> BLANK = NONE ® SUPPLY DIFFUSER THERMOSTAT <br /> X-X THERMOMETER ON NIGHT PRESSURE RELIEF VALVE <br /> SEQUENTIAL # XXX`-XX STARTING W� �]IF <br /> SD 12 6 SDE WALL SUPPLY AIR DIFFUSER, GRILLE, <br /> 100 CM I REGISTER A WATER HAMMER ARRESTOR l� TEMPERATURE TRANSMITTER <br /> FLOOR # ACU-# SIZE BASED ON P.D.I. <br /> RG 12/12 RETURN/EXHAUST REGISTER OR GRILLE, CEILING STANDARD WH-201,SIZE AS SHOWN SD SMOKE DETECTOR <br /> VAV MARK 100 CFM DUCT TYPE. RETURN GRILLE SHOWN "RG" IN HEX. SYMBOL <br /> TRANSFER GRILLE ASSEMBLY WATER HAMMER ARRESTOR DPS I DIFFERENTIAL PRESSURE SWITCH <br /> (PLAN VIEW) <br /> 1000 CFM ® FLOOR ENTRY HATCH ASSEMBLY ��'Affiliated <br /> �- RETURN, OUTSIDE OR EXHAUST m Engineers FOR REFERENCE ONLY <br /> AIR FLOW DIRECTION Afrtlaled Eagi...s,m0. <br /> 5802 Roseorch Park Boulevard <br /> Madison,Wisconsin 53719 <br /> SUPPLY AIR FLOW DIRECTION Tel 608.238.2616 DESIGN BY AL, DATE 01.23.24 <br /> Pralect�': <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE <br /> p FRI ACCEPTABILITY CADD 11 20 96 <br /> WAs„M MECHANICAL LEGEND&ABBREVIATIONS W8861360 01.23.24 <br /> RECORD DRAWING ISSUED TO OWNER FEW FEW 09.29.97 �a Hof >,A THIS DESIGN AND/OR PRO BHECKED <br /> or SPECIFICATION IS APPROVED FEW 11 21 96 SHEET <br /> ® �_ °z TITLE 737 NORTH LINE - 40-36 TOWER RELOCATIONS DP 36.01 A 787 FA RECORD SET 555886 WH J. MENIKETTI 06.22.07 APPROVED BY DEPT. DATE M 0 a <br /> OE//V6 _ CHECKED <br /> B 737 NORTH LINE—40-36 TOWER RELOCATIONS DP 36.01 W8861360 AEI J.B.,J.P. 01.23.24 —AT4b486� BUILDING 40-36 <br /> ALStt` APPROVED JOB NO. 23722226 COMP N00021855 <br /> 01/23/2024 APPROVED MECHANICAL MASTER EVERETT DWG NO. 40-36-MOa <br />
The URL can be used to link to this page
Your browser does not support the video tag.