5631 10TH DR W 2024 Plans 2025-07-01
>
Address Records
>
10TH DR W
>
5631
>
Plans
>
5631 10TH DR W 2024 Plans 2025-07-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/4/2025 9:26:54 AM
Creation date
6/4/2025 9:26:54 AM
Metadata
Fields
Template:
Address Document
Street Name
10TH DR W
Street Number
5631
Permit
B2409-004
Year
2024
Notes
REPLACING INTERIOR GARAGE POST WITH ENGINEERED BEAM
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Project Title: <br /> Engineer: <br /> Project ID: <br /> Project Descr: <br /> Steel Beam Project File:Crawford Residence.ec6 <br /> LIC#:KW-06015244,Build:20.24.06.04 CG ENGINEERING (c)ENERCALC INC 1983-2023 <br /> DESCRIPTION: Beam 1 - channel <br /> CODE REFERENCES <br /> Calculations per AISC 360-16, IBC 2021,ASCE 7-16 <br /> Load Combination Set : IBC 2021 <br /> Material Properties <br /> Analysis Method Allowable Strength Design Fy:Steel Yield : 36.0 ksi <br /> Beam Bracing: Beam is Fully Braced against lateral-torsional buckling E: Modulus: 29,000.0 ksi <br /> Bending Axis: Major Axis Bending <br /> D(0.2450)L(0.1250)S(0.2630) <br /> C10x30 <br /> Al <br /> 1 2 <br /> Span=22.0 ft <br /> Applied Loads Service loads entered. Load Factors will be applied for calculations. <br /> Beam self weight calculated and added to loading <br /> Uniform Load : D =0.2450, L=0.1250, S=0.2630 k/ft, Tributary Width = 1.0 ft, (1/2 Total Loads) <br /> DESIGN SUMMARY • <br /> Maximum Bending Stress Ratio = 0.714: 1 Maximum Shear Stress Ratio= 0.072 : 1 <br /> Section used for this span C10x30 Section used for this span C10x30 <br /> Ma:Applied 34.243 k-ft Va:Applied 6.226 k <br /> Mn/Omega:Allowable 47.964 k-ft Vn/Omega:Allowable 87.047 k <br /> Load Combination +D+0.750L+0.750S Load Combination +D+0.750L+0.750S <br /> Location of maximum on span 0.000 ft <br /> Span#where maximum occurs Span#1 Span#where maximum occurs Span#1 <br /> Maximum Deflection <br /> Max Downward Transient Deflection 0.466 in Ratio= 566 > 360 Span: 1 :S Only <br /> Max Upward Transient Deflection 0 in Ratio= 0 <360 n/a <br /> Max Downward Total Deflection 1.003 in Ratio= 263 >=240. Span: 1 : +D+0.750L+0.750S <br /> Max Upward Total Deflection 0 in Ratio= 0 <240.0 n/a <br /> Vertical Reactions Support notation:Far left is#' Values in KIPS <br /> Load Combination Support 1 Support 2 <br /> Max Upward from all Load Conditions 6.226 6.226 <br /> Max Upward from Load Combinations 6.226 6.226 <br /> Max Upward from Load Cases 3.025 3.025 <br /> D Only 3.025 3.025 <br /> +D+L 4.400 4.400 <br /> +D+S 5.918 5.918 <br /> +D+0.750L 4.056 4.056 <br /> +D+0.750L+0.750S 6.226 6.226 <br /> +0.60D 1.815 1.815 <br /> L Only 1.375 1.375 <br /> S Only 2.893 2.893 <br /> 7 <br />