My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD 2024 BLDG 40-26 Plans 2025-07-01 (2)
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-26
>
Plans
>
3003 W CASINO RD 2024 BLDG 40-26 Plans 2025-07-01 (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/5/2025 7:16:08 AM
Creation date
6/5/2025 7:15:41 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-26
Permit
M2403-039
Year
2024
Notes
TOWER RELOCATION
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ABBREVIATIONS LEGEND <br /> A COMPRESSED AIR FLR FLOOR SA SUPPLY AIR GENERAL DUCTWORK SANITARY WASTE PIPING AND FITTINGS PIPING IDENTIFICATION <br /> AAV AUTOMATIC AIR VENT FPM FEET PER MINUTE SAN SANITARY 24x12 RECTANGULAR DUCT, FIRST NUMBER AIR TERMINALS (CONTINUED) <br /> AD ACCESS DOOR FT FEET SD SMOKE DAMPER 2412 INDICATES SIZE FOR SIDE SHOWN EXHAUST GRILLE/REGISTER 0 FFD FUNNEL FLOOR DRAIN —CHWS— CHILLED WATER SUPPLY <br /> AFF ABOVE FINISHED FLOOR SENS SENSIBLE 1 z <br /> AP ACCESS PANEL GA GAUGE SP STATIC PRESSURE !kr� (WALL) RFD FLOOR DRAIN CHWR CHILLED WATER RETURN <br /> EXISTING DUCT TO BE REMOVED <br /> AHU AIR HANDLING UNIT GAL GALLON <br /> SO SQUARE CD—XXX o FCO FLOOR CLEANOUT CW <br /> Al ANALOG INPUT GALV GALVANIZED SS STAINLESS STEEL 24x1T SUPPLY AIR DUCT SHOWN IN SECTION, ARROW — CITY WATER (DOMESTIC) <br /> AO ANALOG OUTPUT GV GROOVED JOINT WITH COUPLING STM STEAM POINTS TO SIDE CALLED OUT FIRST SQUARE SUPPLY AIR DIFFUSER <br /> A/C AIR CONDITIONING GPH GALLONS PER HOUR CO CLEANOUT, EXPOSED CITY WATER (DOMESTIC) <br /> AW AQUEOUS WASH GPM GALLONS PER MINUTE TEFC TOTALLY ENCLOSED FAN COOLED 24x1' RETURN, EXHAUST OR OUTDOOR AIR DUCT SHOWN IN RG/EG/TG—XXX <br /> AWN AQUEOUS WASH WASTE GWB GYPSUM WALL BOARD TEMP TEMPERATURE SECTION, ARROW POINTS TO SIDE CALLED OUT FIRST � WCO WALL CLEANOUT A COMPRESSED AIR (100 PSIG NOMINAL) <br /> AWtND AQUEOUS WASH WASTE DRAIN TYP TYPICAL Er RETURN/EXHUAST/TRANSFER GRILLE LATERAL HW HOT WATER (DOMESTIC) <br /> HOA HAND OFF AUTO 24 � ROUND DUCT, NUMBER 74 <br /> BHP BRAKE HORSEPOWER HP HORSE POWER V VOLTS 24 0 INDICATES DIAMETER <br /> DOOR AIR TRANSFER GRILLE SANITARY WYE AND 1/8 BEND — — — — HOT WATER (DOMESTIC) <br /> VAV VARIABLE AIR VOLUME BLDG BUILDING HE HOUR <br /> BTU BRITISH THERMAL UNIT HWC HOT WATER CIRCULATING MEL VELOCITY SUPPLY AIR DUCT, SQUARE OR F ROOF AIR INTAKE — AHU WASTE PIPING QUARTER BEND HWC— HOT WATER CIRCULATING (DOMESTIC) <br /> HZ HERTZ VERT VERTICAL RECTANGULAR,ELBOW TURNING TOWARD = �� <br /> CAP CAPACITY HxW HEIGHT BY WIDTH VFD VARIABLE SPEED DRIVEo WASTE PIPING BEND WITH CLEANOUT — — — — — HOT WATER CIRCULATING (DOMESTIC) <br /> CFM CUBIC FEET PER MINUTE VTR VENT TO ROOF SUPPLY AIR DUCT, SQUARE OR t <br /> C CENTER LINE IN INCHES W WITH RECTANGULAR ELBOW TURNING AWAY LPS LOW PRESSURE STEAM <br /> COL COLUMN W INDUSTRIAL WASTE WB WET BULB <br /> CONN CONNECTION WG WATER GAUGE RETURN AIR DUCT, SQUARE OR ROOF DRAIN PIPING MPS MEDIUM PRESSURE STEAM <br /> CW CITY WATER (DOMESTIC) KW KILOWATT WHA WATER HAMMER ARRESTER RECTANGULAR ELBOW TURNING TOWARD <br /> CMU CONCRETE MASONRY UNIT WxH WIDTH BY HEIGHT GENERAL PIPING RD ROOF DRAIN C GRAVITY STEAM CONDENSATE RETURN <br /> CHWS/R CHILLED WATER SUPPLY/RETURN LBS POUNDS RETURN AIR DUCT, SQUARE OR <br /> LWT LEAVING WATER TEMPERATURE #" # — INCHES RECTANGULAR ELBOW TURNING AWAY NEW AND EXISTING WORK — O VTR VENT THROUGH ROOF CD GRAVITY COOLING COIL CONDENSATE DRAIN <br /> D INDIRECT DRAIN # — FEET DESIGNATED BY NOTE <br /> # ROUND DUCT <br /> DB DRY BULB MAX MAXIMUM ROUND DIAMETER ELBOW TURNING TOWARD EXISTING TO BE REMOVED DIED OVERFLOW DRAIN CV CONDENSATE RELIEVER VENT <br /> DDC DIRECT DIGITAL CONROL MBH THOUSAND BTU PER HOUR F DEGREES FAHRENHEIT <br /> DISCH DISCHARGE MECH MECHNICAL AD PRESSURE DIFFERENCE/ SAN SANITARY WASTE ABOVE GRADE <br /> PRESSURE DROP ROUND DUCT PLUMBING FIXTURES <br /> DI DIGITAL INPUT MIN MINIMUM ELBOW TURNING AWAY —————— HIDDEN OR BELOW GRADE <br /> DIA DIAMETER ----SAN---- SANITARY WASTE BELOW GRADE <br /> DIFF DIFFERENCE NC NOISE CRITERIA TRANSITION, RECTANGULAR TO RECTANGULAR TTJ ❑ EWC ELECTRIC WATER COOLER <br /> DN DOWN NO NORMALLY OPEN OR ROUND TO ROUND CONNECTING LINES V SANITARY VENT ABOVE GRADE <br /> DO DIGITAL OURPUT --V----CA OUTDOOR AIR TRANSITION, <br /> OR OVAL OD RECTANGULAR <br /> U AR I Q 4 WC-1 WATER CLOSET SANITARY VENT BELOW GRADE <br /> TO ROUND EAT ENTERING AIR TEMPERATURE OC ON CENTERS CROSSING LINES, NON—CONNECTING (TOP OR F FIRE WATER MAIN <br /> ELF EFFICIENCY I EL ELEVATION PCW PUMPED COLD WATER � FLEXIBLE DUCT FRONT PIPE IS SHOWN AS SOLID LINE) Q URINAL (UPSTREAM OF ALARM VALVE) <br /> ELEC ELECTRICAL PD PRESSURE DROP OR PRESSURE DIFFERENTIAL <br /> EMS ENERGY MANAGEMENT SYSTEM PH PHASE PUMP (IN — LINE) S FIRE SPRINKLER PIPING <br /> DOWNSTREAM OF ALARM VALVE) <br /> EMCS ENERGY MANAGEMENT CONTROL SYSTEM PNEU PNEUMATIC RECTANGULAR DUCT, SQUARE ELBOW ® � LAVATORY <br /> EWT ENTERING WATER TEMPTERATURE POC POINT OF CONNECTION WITH TURNING VANES PUMP TEST ALARM VALVE TEST PIPING <br /> EXH EXHAUST PSI POUNDS PER SQUARE INCH <br /> EXIST EXISTING PSIG PSI GUAGE ❑ ACCESS DOOR (AD) OR ❑ SERVICE SINK PHW PUMPED HOT WATER (DOMESTIC) <br /> EXT EXTERNAL RAG RETURN AIR GRILL ACCESS PANEL (AP) _ INSULATED PIPE <br /> DUCT MOUNTED EQUIPMENT pCW PUMPED CITY WATER (DOMESTIC) <br /> FC FAN COIL REF REFERENCE AD ACCESS DOOR BREAK IN PIPE USE WHERE SECTION OF PIPING <br /> FCO FLOOR CLEANOUT 1— ( CENTRIFUGAL FAN <br /> RM ROOM IS OMITTED FROM DRAWING FOR CLARITY) � PC PUMPED STEAM CONDENSATE <br /> FDG FLOOR FOR <br /> FIGURE RPMRPM REVOLUTIONS PER MINUTE LINED <br /> DUCT (DUCT NET FREE AREA)DIMENSIONS ARE DIRECTION OF FLOW CENTRIFUGAL FAN, INLET GUIDE VANES PIW PUMPED INDUSTRIAL WASTE <br /> INSTRUMENTATION IDENTIFICATION LETTERS RWL RAIN WATER LEADER <br /> FIRST LETTER 11 SUCCEEDING LETTER ❑ FLEXIBLE CONNECTION SLOPE DIN DIRECTION OF SLOPE DOWN <br /> RETURN AIR DUCT, SQUARE OR VALVES <br /> MEASURED OR MODIFIER READOUT OR OUTPUT MODIFIER RECTANGULAR ELBOW TURNING TOWARD <br /> INITIATING PASSIVE FUNCTION DUCT OFFSET UP OR DOWN FLEX CONNECTION <br /> VARIABLE FUNCTION X ��� BALL VALVE <br /> �I BLIND FLANGE X <br /> A ANALYSIS ALARM AIR DAMPERS �> BUTTERFLY VALVE <br /> B BURNER/ ] CAPPED PIPE END F—H FAN POWERED AIR TERMINAL UNIT WITH GATE VALVE <br /> COMBUSTION VOLUME DAMPER ACOUSTICALRETURN BOOT AND FILTER <br /> C CONTROL CONTROL i�=i �� PLUGGED PIPE END F ELECTRICAL CLEARANCE GLOBE VALVE <br /> D DIFFERENTIAL AAV L— AIR TERMINAL UNIT ANGLE GLOBE VALVE, ELEVATION/PLAN <br /> E VOLTAGE SENSOR PRIMARY NOTE: OPPOSED BLADE DAMPER AUTOMATIC AIR VENT —$ �a <br /> ( BLDG EL. 100'-0" = SITE EL 548.33' Q SOUND BOOT AND FILTER <br /> ELEMENT) PRESSURE GAUGE WITH VALVE N CHECK VALVE <br /> DUCT DAMPER, MOTOR OPERATED F—H FAN POWERED AIR TERMINAL <br /> F FLOW RATE RATIO POINT OF CONNECTION DM (ELECTRIC OR PNEUMATIC) �� ELBOW TURNED DOWN OR AWAY L UNIT WITH FILTER 5 SOLENOID OPERATED VALVE <br /> G GLASS ELEVATION STATION SYMBOL PARALLEL BLADE DAMPER 'u ELBOW TURNED UP OR TOWARD ELECTRICAL CLEARANCE BALANCING VALVE <br /> H HAND HIGH AIR TERMINAL UNIT <br /> I CURRENT INDICATE v FD v FS 0 FILTER BALANCING VALVE W/ METERING PORTS <br /> � REDUCER, CONCENTRIC Q� <br /> J POWER SCAN FIRE DAMPER FIRE/SMOKE DAMPER INSTRUMENTATION AND CONTROL C� 2-WAY CONTROL VALVE <br /> K TIME, TIME TIME RATE SECTION LETTER OR DETAIL NUMBER (VERTICAL) (VERTICAL) A REDUCER, ECCENTRIC <br /> SCHEDULE OF CHANGE FD FIRE DAMPER FS FIRE SMOKE DAMPER TEMPERATURE SENSOR, HUMIDITY SENSOR, 3-WAY CONTROL VALVE <br /> L LEVEL LIGHT LOW SHEET SHOWN ON / STRAINER SMOKE DETECTOR, DUCT MOUNTED <br /> AUTOMATIC O CONTROL <br /> M MOMEARY MIDDLE SHEET TAKEN FROM BD (HORIZONTAL) (HORIZONTAL) 400 <br /> NT TEE �� � (NUMBERINDICATESGPM) VALVE <br /> 0 ORIFICE <br /> BACKDRAFT DAMPER obi PLUG VALVE <br /> SECTION/DETAIL MARK moo— TEE UP <br /> P PRESSURE POINT (TEST) 1 (D TEMPERATURE SENSOR <br /> CONNECTION CONICAL TAP (WALL MOUNTED) BFP BACKFLOW PREVENTER <br /> Q QUANTITY INTEGRATE, i�(S) SUPPLY, (R) RETURN, (E) EXHAUST <br /> TEE DOWN THERMOSTAT - WALL <br /> TOTALIZE S-100— AIRFLOW (CUBIC FEET PER MINUTE) 45 DEGREE LATERAL TAP ---a— FLOAT AND THERMOSTATIC , N THERMOSTAT - NIGHT PRESSURE REDUCING VALVE <br /> R RADIATION RECORD D1:6 TRAP ASSEMBLY OS & Y VALVE <br /> S SPEED SAFETY SWITCH DIFFUSER NECK SIZE ❑ TEMPERATURE TRANSMITTER <br /> AIR TERMINALS PIPE ALIGNMENT GUIDE PRESSURE RELIEF VALVE <br /> T TEMPERATURE TRANSMITTER DIFFUSER TYPE SD SMOKE DETECTOR <br /> U MULTIVARIABLE MULTIFUNCTION MULTIFUNCTION MULTIFUNCTION �� SUPPLY DIFFUSER <br /> V VIBRATION VALVE/DAMPER PT PLUG DP DIFFERENTIAL PRESSURE SWITCH <br /> DIFFUSER/GRILLE MARK SD 12x6 SIDE WALL SUPPLY AIR DIFFUSER, GRILLE, MODULATING CONTROL VALVE <br /> W WEIGHT/FORCE WELL �100 CFM OR REGISTER ® CARBON DIOXIDE SENSOR <br /> X UNCLASSFIED �VAV\\ THERMOMETER Im AIRFLOW SENSOR 1/8" 1� INDICATES SLOPE <br /> Y EVENT, STATE RELAY, COMPUTE, RGN12x12 RETURN/EXHAUST REGISTER OR GRILLE, CEILING <br /> 100 CFM DUCT TYPE. RETURN GRILLE SHOWN "RG" <br /> OR PRESENCE OR CONVERT q WATER HAMMER ARRESTOR <br /> Z POSITION DRIVER, ACTUATOR <br /> FLOOR # SEQUENTIAL # SIZE BASED ON P.D.I. Affiliated <br /> TRANSFER GRILLE ASSEMBLY STANDARD WH-201,SIZE AS SHOWN � <br /> (E) 1000 CFM � Engineers <br /> X LOCAL INSTRUMENT XXX PANEL MOUNTED INSTRUMENT XXX EXISTING INSTRUMENTATION VAV MARK N HEX. SYMBOLFOR REFERENCE ONLY <br /> Affiliated Engineers,Inc. <br /> �— RETURN, OUTSIDE OR EXHAUST seoz Reseoren Park Bowe�ora <br /> AIR FLOW DIRECTION WATER HAMMER ARRESTOR MIMI—Wier ire 53719 <br /> INSTRUMENT FURNISHED WITH EQUIPMENT XXX SHARED HMI DISPLAY y (PLAN VIEW) Tel 608.238.2616 <br /> SUPPLY AIR FLOW DIRECTION Project#: FACILITY DESIGN BY AD DATE 01.29.24 <br /> DRAWN DATE SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ACCEPTABILITY CAR n zo ss <br /> MECHANICAL LEGEND&ABBREVIATIONS W8861360 N 01.29.24 <br /> D AAS SUBTITLE CURRENT REVISION SYMBOL GATE o <br /> HIS DESIGN AND/oR CHECKED <br /> K THIRD FLOOR CONFERENCE CENTER - IFC 586992-01 SAG/WH GEL 10.22.08 E 787 PIC THIRD FLOOR -30% 586992-01 SAG/WH GEL 08,14.08 �4"re'E4 SPECIFICATION IS APPROVED FPW EWR 11 21 96 SHEET <br /> L 787 PIC DCN#4 586992-00 SAG/WH GEL 10.24.08 F 787 PRODUCTION INTEGRATION CENTER- 90% 586992-00 SAG/WH GEL 08.29.08 ® " n`aro APPROVED BY DEPT. DATE EWR TITLE 737 NORTH LINE 40-26 TOWER RELOCATIONS DP 26.04 M OA \ <br /> BOE//VG �^o CHECKED <br /> — RECORD DRAWING CLEAN—UP J#586992-00 586992-01 DLR GROUP S. GORE 05.28.09 G 787 PIC THIRD FLOOR — 60% 586992-01 SAG/WH CEL 08.29.08 z LAD BUILDING 40-026 <br /> JOB NO. COMP N0.8' . <br /> M 787 SURGE LINE WH SAG 10.15.12 H 787 PRODUCTION INTEGRATION CENTER- IFC 586992-00 SAG/WH GEL 09.12.08 �,am APPROVED _ <br /> b„q��� WJP 00021855 <br /> N 737 NORTH LINE-40-26 TOWER RELOCATIONS DP 26.04 W8861360 AEI J.B.,J.P. 01,29.24 J THIRD FLOOR CONFERENCE CENTER- 60% 586992-01 SAG/WH GEL 10.10.08 oinano24 APPROVED MECHANICAL MASTER EVERETT, WA DWG No. 40-026-MOA <br />
The URL can be used to link to this page
Your browser does not support the video tag.