T HARDWARE SETS: <br /> 7 T-6" T-0" T-O" 6 EQ PANELS HS-1 SINGLE NON-RATED DOOR WITH LATCHSET HS-2 SINGLE FRAMELESS GLASS DOOR WITH CARD READER <br /> 4'MAX PANELS,REFER TO PLAN <br /> 11 I-10.1 QTV 1-1/2 PAIR-BUTT HINGES FLOOR MOUNT BOTTOM PIVOT SET <br /> SIM. y 11 QTY 1-LEVER LATCHSET OVERHEAD CONCEALED CLOSER <br /> BLDG.STD.FLUSH PANEL WOOD KE <br /> NEW HEADER.REFER TO STRUCTURAL QTY 1-BLDG STD.DOOR STOP BLUMCRAFT PANIC DEVICE TYPED V <br /> DOOR — — — — -10.2—SIfoY -10.1 ACT CEILING QTYI SET-SILENCERS <br /> PEMCO AUTO DOOR BOTTOM ELECTRIC STEL STRIKE KEEPER <br /> FINISH:BLDG.STD.STAIN ACOUSTIC SEALS Lu <br /> / TEMPERED SAFETY GLASS / <br /> / P /- 1/2"TEMPEC,2406 SAFETY GLASS <br /> PER IBC SEC.2406 <br /> PER IBC SEC.2406 DOOR NOTES: I 10 <br /> N <br /> 7 / <br /> 10 1. PROVIDE AND INSTALL DIAGONAL BRACE(TO MATCH WALL FRAMING)AT THE LATCH SIDE OF ALL NEW DOOR FRAMES,ABOVE ate+ <br /> _10.1 1'A" 10.1 9 12 CEILING,EITHER TO ADJACENT WALL FRAMING OR TO STRUCTURE ABOVE. to <br /> 102 2. GC TO COORDINATE JAMB DEPTH WITH FINISHED WALL WIDTH PRIOR TO ORDERING FRAMES. tol <br /> 3. ALL EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. Lu <br /> \ \ 4. ALL GLAZING SHALL CONFORM TO SAFETY GLAZING REQUIREMENTS OF IBC SECTION 2406. Z V <br /> 5, MAGNETIC HOLD OPEN DEVICES SHALL BE TIED TO BUILDING FIRE ALARM SYSTEM. N p <br /> E \ 11 NOTE @ DOORIRELITE 6. ALL RATED DOORS TO BE LABELED PER IBC TABLE 716.29. 00 <br /> 1-10.1 COMBINATION:PROVIDE 7. THRESHOLDS AT DOORWAYS SHALL BE 1/2"MAXIMUM IN HEIGHT.PER ICC/ANSI A117.1 SECTION 404.2.4. P <br /> N <br /> METAL STUD KICKERS 8. ICC/ANSI A117.1 SECTION 404.2.6.DOOR HARDWARE.HANDLES,PULLS,LATCHES,LOCKS&OTHER OPERABLE PARTS ON ACCESSIBLE Q Q <br /> SUPPORT UP TO STRUCT. DOORS SHALL HAVE A SHAPE THAT IS EACH TO GRASP WITH ONE HAND&DOES NOT REQUIRE TIGHT GRASPING,PINCHING,OR L <br /> FOR STABILITY. TWISTING OF THE WRIST TO OPERATE.OPERABLE PARTS OF SUCH HARDWARE SHALL BE 34'MIN.&48"MAX.ABOVE THE FINISH N <br /> BASE,AS SPECIFIED FLOOR.WHERE SLIDING DOORS ARE IN THE FULLY OPEN POSITION.OPERATING HARDWARE SHALL BE EXPOSED&USABLE FROM <br /> BOTH SIDES. N <br /> 9. ICC/ANSI A117.1 DOOR OPENING FORCE.FIRE DOORS SHALL HAVE THE MINIMUM OPENING FORCE ALLOWABLE BY THE APPROPRIATE O� — <br /> 1 DOOR TYPE A 2 I <br /> DOOR TYPE B - NORTH ELEVATION ADMINISTRATIVE AUTHORITY.THE MAXIMUM FORCE FOR PUSHING OPEN FOR PULL NG OPEN DOORS OTHER THAN FIRE DOORS <br /> SCALE:3I8"=1'-0' SCALE:3I8"=1'-0- Q SHALL BE AS FOLLOWS:1.INTERIOR HINGED DOOR:5.0 POUNDS(22.2 N)2.SLIDING OR FOLDING DOOR:5.0 POUNDS(22.2 N).THESE P rb <br /> 1 FORCES DO NOT APPLY TO THE FORCE REQUIRED TO RETRACT LATCH BOLTS OR DISENGAGE OTHER DEVICES THAT HOLD THE <br /> DOOR IN A CLOSED POSITION. <br /> 10, ACTIVATION OF THE BUILDING AUTOMATIC SPRINKLER OR FIRE DETECTION SYSTEM,IF PROVIDED,SHALL AUTOMATICALLY UNLOCK <br /> 11 ALL ELECTRONICALLY SECURED DOORS WITH IN THE EGRESS PATHWAY.THE DOORS SHALL REMAIN UNLOCKED UNTIL THE FIRE <br /> ALARM HAS BEEN RESET.EXTERIOR HINGED,SLIDING,OR FOLDING DOOR:10.0 LBS(44.4 N). T C O D n o 1 n I C D <br /> -10.1 11. ENTRANCE DOORS IN BUILDINGS WITH OCCUPANCY IN GROUP A,B,E OR M SHALL NOT BE SECURED FROM THE EGRESS SIDE I C R R r V V C R <br /> DURING PERIODS THAT THE BUILDING 18 OPEN TO THE GENERAL PUBLIC. <br /> BUILDING A <br /> \ DOOR SCHEDULE: FLOOR 2 <br /> 3315 SEAWAY BLVD. <br /> DOOR FRAME EVERETT, WA 98203 <br /> 5 <br /> wSIZE DETAILS <br /> IE <br /> EXISTING DOOR TO BE REUSED W z LL p <br /> o 0 o p a <br /> \ NO. ROOM HDWE RATING REMARKS <br /> RED SAFETY <br /> GLASS PER IBC SEC.2406 <br /> 202 HUDDLE A WD BS 3'-0' T-0" ALUM CLR 7 8 6 HS-1 NONE DESIGN JPC <br /> 11 / GLASS PER <br /> I-10.1 207 STAIR B GLASS 31' 1-4-" W DRAWN TSJA NIA 9 9 HS-2 NONE CHECKED AN <br /> NO. 24-0035 <br /> 4'-0" <br /> 4 DOOR TYPE C - CONFERENCE ROOM 5 NOT USED &NOT` USED <br /> SCALE:3l6"=1'- SCALE:V <br /> SHIM AS REQUIRED ALUMINUM FRAME, <br /> CLEAR ANODIZED FINISH NEW HEADER.REFER TO STRUCTURAL <br /> 6389 REGISTERED <br /> DOOR PER <br /> SCHEDULE - � - ARCHITECT <br /> DOUSLESTUDSAT �^ • <br /> EACH MARK A.PETERSON <br /> SIDE OF JAMBS BRUSHED STAINLESS STATE OF WASHINGTON <br /> GLAZING HEAD CHANNEL <br /> BRUSHED STAINLESS DOOR RAIL CLEAR TEMPERED GLASS <br /> BRUSHED STAINLESS BOTTOM <br /> SPECIFIED PARTITION PIVOT PER MANUFACTURERS 5.10.2024 PERMIT SET <br /> INTERSECTING SPECIFICATIONS 9.17.2024 CD SET <br /> WALL AT HINGE FLOORING AS SPECIFIED <br /> SIDE OF FRAME Qi l l.06.2024 TENANT REVISION <br /> IL <br /> 6"UNO (WHERE OCCURS) <br /> L Ll—J <br /> DOOR JAMB HEAD SIMILAR 8 NOT USED ��1 GLASS PIVOT DOOR HEAD AND SILL <br /> SCALE:6"=1'-0' SCALE. SCALE:3"=V-D" <br /> '"CUR' <br /> TEMPERED GLASS <br /> SIDELITE CHANNEL SET AT <br /> FLOOR AND CEILING. <br /> ATTACHMENT AT CEILING PER STRUCTURAL <br /> CLEAR SILICONE SEALANT <br /> MAX.1/8'GAP WITH CLEAR <br /> s SILICONE CAULK BLOCKING <br /> FASTEN BLOCKING TO METAL WALL WITH <br /> (2) 10#SCREWS @ 24"OC <br /> TEMPERED SAFETY <br /> GLAZING SET WITH GLAZING 1-1/2'X1'4"BRUSHED ALUMINUM CHANNEL W/ JURisoicnory sraMr <br /> TAPE AT ENTIRE PERIMETER CLEAR SEALANT <br /> TDOOR SCHEDULE & <br /> CLEAR TEMPERED GLASS PANELS DETAILS <br /> �a <br /> 1"X1"X'-3"BRUSHED ALUMINUM REFER TO STRUCTURAL <br /> CHANNEL W/CLEAR SEALANT <br /> ' FLOORING AS SPECIFIED <br /> LINE OF BASE BELOW I 1 O. I <br /> 1 <br /> 10 BUTT JOINED GLAZING 11 RECITE HEAD AND SILL CHANNEL 12 GLAZING AT EXISTING WALL <br /> 3 5 SCALE:6"=1'-0' SCALE:3"=1'-0'8 SCALE:6"=1'-0" ©202a JvC uiCrvirecis,LLc <br /> L City of Everett Permit Services <br /> EVERETT Reviewed for Permit 01/09/2025 <br />