Laserfiche WebLink
T CODE CALCULATIONS: <br /> 1. REQUIRED EGRESS WIDTH: <br /> 1.1. EGRESS WIDTHS REQUIRED PER IBC 1005.3.1&1005.3.2: <br /> 1.2. STAIRS:0.3"/OCCUPANT <br /> 1.3. OTHER COMPONENTS:0.2'/OCCUPANT r <br /> 2. MAXIMUM OCCUPANT LOAD LIMITED BY STAIRWAYS: W <br /> 106"(TOTAL STAIR WIDTH)10.3=353 MAXIMUM OCCUPANTS <br /> 3. MAXIMUM OCCUPANT LOAD LIMITED BY OTHER EGRESS COMPONENTS: <br /> 72'(TOTAL DOOR WIDTH)/0.2=360 MAXIMUM OCCUPANTS <br /> EXIT 4. (2)MINIM HAVE BEEN PROVIDED <br /> PER IBC 1006.2.1I1006.3.2. <br /> EXIT (2)EXITS HAVE BEEN PROVIDED. ,p <br /> I 777=74� M"7-1 <br /> 5. ALL CONFERENCE ROOMS UNDER 50 OCCUPANTS(OR 750 SF)TO BE <br /> I I _LLLLLLLL7,_ <br /> N <br /> � � CONSIDERED B OCCUPANCY PER IBC 303.1.2. .ate+ <br /> 7 <br /> fi. "COMMON PATH OF EGRESS TRAVEL'FOR B OCCUPANCY TO BE 100'-D"OR Ln <br /> A-3 USE I F IBC LESS TABLE 1006.2.1.(75'-0"WITHOUT OR SPRINKLERS THROUGHOUT BLDG)AS ALLOWED PER LU <br /> 1.15 452 S <br /> � <br /> B 31 OCC <br /> 7. "EXIT ACCESS TRAVEL DISTANCE"FOR B OCCUPANCY TO BE 300'-0'OR LESS 0. <br /> AS ALLOWEDPERIBC TABLE1017.2. N D` <br /> 7.1. EXIT TRAVEL DISTANCE SHALL BE MEASURED TO EXIT DISCHARGE OR Q Q <br /> EXIT STAIR,BUT CONTINUE DOWN A EXIT ACCESS STAIR. L <br /> � 8. DEAD-END CORRIDORS TO BE LESS THAN 20'-0".(50'4'IF FULLY SPRINKLERED j <br /> _ TRAVEL DIST.97''-" a _ I TRAVE DIST.7SAI AND B,E,F,OR S OCCUPANCY)PER IBC 1020.4. N <br /> P m <br /> CODE NOTES: <br /> O O O O ®® O 1. MEANS OF EGRESS ILLUMINATION:THE MEANS OF EGRESS(EXIT PATHWAY) T E R RA P O W E R <br /> COMMON PATH OF AND THE EXIT DISCHARGE DOOR SHALL BE ILLUMINATED AT ALL TIMES THE <br /> TRAVEL 19'-0" BUILDING IS OCCUPIED AT AN ILLUMINATION LEVEL NOT LESS THAN 1-FOOT p <br /> CANDLE (10 LUX)AT THE WALKING SURFACE LEVEL PER IBC 1008. BUILDING A <br /> LIGHTING MUST BE PROVIDED WITH EMERGENCY BATTERY BACK-UP PER IBC <br /> 1008.3, FLOOR 2 <br /> 2. EGRESS LIGHTING SHALL BE DESIGNED BY A LICENSED ELECTRICAL 3315 SEAWAY BLVD. <br /> ACCORDING TO APPLICABLE CODESIORDINANCES IN JURISDICTON. <br /> THEINEER ENGINEER MAY REFERENCE THIS CODE SUMMARY SHEET.HOWEVER,IT EVERETT, WA 98203 <br /> SHALL REMAIN THE SOLE RESPONSIBILITY OF THE ENGINEER TO COMPLETE A <br /> SCOPE OF WORK ADDRESSING ALL EGRESS LIGHTING I.E.;ROOMS, <br /> SPECIALIZED SPACES,PATHWAYS,ETC.PER THE AFOREMENTIONED CODES. <br /> //�- FINAL EGRESS LIGHTING DESIGN SUBJECT TO BUILDING OFFICIAL DISCRETION. <br /> �A\I <br /> \I I l 3. EGRESS DOORS WITH CARD READERS SHALL BE FAIL-SAFE TO REMAIN <br /> 1W. VV �/ UNLOCKED DURING AN EVENT/EMERGENCY PER IBC 1010.1.9. <br /> 4. NON-EGRESS DOOR WITH CARD READERS SHALL BE FAIL SECURE TO REMAIN DESIGN JPC <br /> LOCKED DURING AN EVENT/EMERGENCY.DOOR CAN STILL BE OPENED WITH A DRAWN TSJ <br /> KEY DURING SUCH EVENT/EMERGENCY. CHECKED AN <br /> 5. FIRE EXTINGUISHERS MUST BE WITHIN A 75'MAXIMUM TRAVEL DISTANCE OF NO. 24-0035 <br /> ' ANY LOCATION. <br /> �\ PARTIAL FIRST FLOOR EXIT PLAN PLUMBING CALCULATION: <br /> _ SCALE:NTS NO CHANGE OF USE OR CHANGE TO OCCUPANT LOAD IS REQUIRED FOR THIS SCOPE <br /> OF WORK.THEREFORE,EXISTING RESTROOM/PLUMBING CALCULATION SHALL <br /> REMAIN. <br /> FLOOR 2 Occupant Load: <br /> REFER TO IBC TABLE 1004.5 FOR LOAD FACTOR <br /> Occupancy Room Name Room Square Load Occupant 6389 REGISTERED <br /> HUDDLE 202 Number Footage Factor Load <br /> ARCHITECT <br /> B HUDDLE ROOM 202 113 } 7.5 <br /> B 7.5 OCC EXIT SEPARATION OPEN OFFICE <br /> 107'-10" B AREA 206 3,700 24.7 '�1 <br /> TOTAL DIAGONAL DISTANCE 3 OCC <br /> B LARGE Zoe 450 30.o MARK A.PETERSON <br /> EXIT CONFERENCE VSTATE OF WASHINGTON <br /> _ � 2056 2055 2052 2051 2048 2047 2044 2043 <br /> 4ETOTAL 4,263 62 <br /> _77707 <br /> CR eR O 1 ❑ 2057 2054 2053 2050 20490 24.70 F 2046 2045 2042 2041 2040 <br /> I1 0 0 o u o 0 <br /> ] KEYNOTES: 5.10.2024 PERMIT SET <br /> Oj a 9.17.2024 CD SET <br /> CR O ADA CLEAR SPACE PER ICC/ANSI A117.1 SECTION 305. Qll.06.2024 TENANTREVISION <br /> AITTRAVEL 015TAWE:IP9'-F EXIT DISTANCE:111, <br /> � EXIT 0 ALL NEW COUNTERS ARE 34"HIGH PER ICC/ANSI A117.1 SECTION 902. <br /> 2001 2006 2007 2012 2013 2018 2019 2024 2025 2 330 2031 2036 203 N <br /> 2002 2 0 51 2008 2011 20,4 2017 0� 2020 2023 2026 2029 2032 2 335 2038 _= LEGEND: <br /> O\PGONP C MMON PATH F <br /> g" V`k", P +III 70RZ7 7PTH OF EGRESS TRAVEL <br /> 2003 2 0 41 2009 2010 2015 2 116 202, 2022 2027 2028 2033 2 334 2039 EXITACCESS TRAVEL DISTANCE <br /> OCCUPANCY <br /> ROOM USE <br /> RM ME 101-ROOM NUMBER <br /> A <br /> B 200 SF ROOM AREA <br /> a 1:150 1.3 OL OCCUPANT LOAD <br /> 3 OCCUPANT LOAD FACTOR <br /> g IV I I n ® EXIT SIGN <br /> �� FIRE EXTINGUISHER isoicnory sraur <br /> O I\VI 1�J o ❑ C <br /> cR CARD READER <br /> EXIT PLAN & CODE <br /> �a <br /> SUMMARY <br /> \SECOND FLOOR EXIT PLAN <br /> e SCALE:1/8"=1'-0" I V <br /> 5 = <br /> 1^' ^/L <br /> 3 $ ©2--a 111 crs,LLc <br /> 8 L City of Everett Permit Services <br /> EVERETT Reviewed for Permit 01/09/2025 <br />