My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3315 SEAWAY BLVD 2024 Plans 2025-07-01
>
Address Records
>
SEAWAY BLVD
>
3315
>
Plans
>
3315 SEAWAY BLVD 2024 Plans 2025-07-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/1/2025 1:34:36 PM
Creation date
6/5/2025 7:22:25 AM
Metadata
Fields
Template:
Address Document
Street Name
SEAWAY BLVD
Street Number
3315
Permit
B2405-036
Year
2024
Notes
T/I 4,107 SF NEW WALLS, FINISHES, CEILINGS, NO CHANGE IN USE
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
T CODE CALCULATIONS: <br /> 1. REQUIRED EGRESS WIDTH: <br /> 1.1. EGRESS WIDTHS REQUIRED PER IBC 1005.3.1&1005.3.2: <br /> 1.2. STAIRS:0.3"/OCCUPANT <br /> 1.3. OTHER COMPONENTS:0.2'/OCCUPANT r <br /> 2. MAXIMUM OCCUPANT LOAD LIMITED BY STAIRWAYS: W <br /> 106"(TOTAL STAIR WIDTH)10.3=353 MAXIMUM OCCUPANTS <br /> 3. MAXIMUM OCCUPANT LOAD LIMITED BY OTHER EGRESS COMPONENTS: <br /> 72'(TOTAL DOOR WIDTH)/0.2=360 MAXIMUM OCCUPANTS <br /> EXIT 4. (2)MINIM HAVE BEEN PROVIDED <br /> PER IBC 1006.2.1I1006.3.2. <br /> EXIT (2)EXITS HAVE BEEN PROVIDED. ,p <br /> I 777=74� M"7-1 <br /> 5. ALL CONFERENCE ROOMS UNDER 50 OCCUPANTS(OR 750 SF)TO BE <br /> I I _LLLLLLLL7,_ <br /> N <br /> � � CONSIDERED B OCCUPANCY PER IBC 303.1.2. .ate+ <br /> 7 <br /> fi. "COMMON PATH OF EGRESS TRAVEL'FOR B OCCUPANCY TO BE 100'-D"OR Ln <br /> A-3 USE I F IBC LESS TABLE 1006.2.1.(75'-0"WITHOUT OR SPRINKLERS THROUGHOUT BLDG)AS ALLOWED PER LU <br /> 1.15 452 S <br /> � <br /> B 31 OCC <br /> 7. "EXIT ACCESS TRAVEL DISTANCE"FOR B OCCUPANCY TO BE 300'-0'OR LESS 0. <br /> AS ALLOWEDPERIBC TABLE1017.2. N D` <br /> 7.1. EXIT TRAVEL DISTANCE SHALL BE MEASURED TO EXIT DISCHARGE OR Q Q <br /> EXIT STAIR,BUT CONTINUE DOWN A EXIT ACCESS STAIR. L <br /> � 8. DEAD-END CORRIDORS TO BE LESS THAN 20'-0".(50'4'IF FULLY SPRINKLERED j <br /> _ TRAVEL DIST.97''-" a _ I TRAVE DIST.7SAI AND B,E,F,OR S OCCUPANCY)PER IBC 1020.4. N <br /> P m <br /> CODE NOTES: <br /> O O O O ®® O 1. MEANS OF EGRESS ILLUMINATION:THE MEANS OF EGRESS(EXIT PATHWAY) T E R RA P O W E R <br /> COMMON PATH OF AND THE EXIT DISCHARGE DOOR SHALL BE ILLUMINATED AT ALL TIMES THE <br /> TRAVEL 19'-0" BUILDING IS OCCUPIED AT AN ILLUMINATION LEVEL NOT LESS THAN 1-FOOT p <br /> CANDLE (10 LUX)AT THE WALKING SURFACE LEVEL PER IBC 1008. BUILDING A <br /> LIGHTING MUST BE PROVIDED WITH EMERGENCY BATTERY BACK-UP PER IBC <br /> 1008.3, FLOOR 2 <br /> 2. EGRESS LIGHTING SHALL BE DESIGNED BY A LICENSED ELECTRICAL 3315 SEAWAY BLVD. <br /> ACCORDING TO APPLICABLE CODESIORDINANCES IN JURISDICTON. <br /> THEINEER ENGINEER MAY REFERENCE THIS CODE SUMMARY SHEET.HOWEVER,IT EVERETT, WA 98203 <br /> SHALL REMAIN THE SOLE RESPONSIBILITY OF THE ENGINEER TO COMPLETE A <br /> SCOPE OF WORK ADDRESSING ALL EGRESS LIGHTING I.E.;ROOMS, <br /> SPECIALIZED SPACES,PATHWAYS,ETC.PER THE AFOREMENTIONED CODES. <br /> //�- FINAL EGRESS LIGHTING DESIGN SUBJECT TO BUILDING OFFICIAL DISCRETION. <br /> �A\I <br /> \I I l 3. EGRESS DOORS WITH CARD READERS SHALL BE FAIL-SAFE TO REMAIN <br /> 1W. VV �/ UNLOCKED DURING AN EVENT/EMERGENCY PER IBC 1010.1.9. <br /> 4. NON-EGRESS DOOR WITH CARD READERS SHALL BE FAIL SECURE TO REMAIN DESIGN JPC <br /> LOCKED DURING AN EVENT/EMERGENCY.DOOR CAN STILL BE OPENED WITH A DRAWN TSJ <br /> KEY DURING SUCH EVENT/EMERGENCY. CHECKED AN <br /> 5. FIRE EXTINGUISHERS MUST BE WITHIN A 75'MAXIMUM TRAVEL DISTANCE OF NO. 24-0035 <br /> ' ANY LOCATION. <br /> �\ PARTIAL FIRST FLOOR EXIT PLAN PLUMBING CALCULATION: <br /> _ SCALE:NTS NO CHANGE OF USE OR CHANGE TO OCCUPANT LOAD IS REQUIRED FOR THIS SCOPE <br /> OF WORK.THEREFORE,EXISTING RESTROOM/PLUMBING CALCULATION SHALL <br /> REMAIN. <br /> FLOOR 2 Occupant Load: <br /> REFER TO IBC TABLE 1004.5 FOR LOAD FACTOR <br /> Occupancy Room Name Room Square Load Occupant 6389 REGISTERED <br /> HUDDLE 202 Number Footage Factor Load <br /> ARCHITECT <br /> B HUDDLE ROOM 202 113 } 7.5 <br /> B 7.5 OCC EXIT SEPARATION OPEN OFFICE <br /> 107'-10" B AREA 206 3,700 24.7 '�1 <br /> TOTAL DIAGONAL DISTANCE 3 OCC <br /> B LARGE Zoe 450 30.o MARK A.PETERSON <br /> EXIT CONFERENCE VSTATE OF WASHINGTON <br /> _ � 2056 2055 2052 2051 2048 2047 2044 2043 <br /> 4ETOTAL 4,263 62 <br /> _77707 <br /> CR eR O 1 ❑ 2057 2054 2053 2050 20490 24.70 F 2046 2045 2042 2041 2040 <br /> I1 0 0 o u o 0 <br /> ] KEYNOTES: 5.10.2024 PERMIT SET <br /> Oj a 9.17.2024 CD SET <br /> CR O ADA CLEAR SPACE PER ICC/ANSI A117.1 SECTION 305. Qll.06.2024 TENANTREVISION <br /> AITTRAVEL 015TAWE:IP9'-F EXIT DISTANCE:111, <br /> � EXIT 0 ALL NEW COUNTERS ARE 34"HIGH PER ICC/ANSI A117.1 SECTION 902. <br /> 2001 2006 2007 2012 2013 2018 2019 2024 2025 2 330 2031 2036 203 N <br /> 2002 2 0 51 2008 2011 20,4 2017 0� 2020 2023 2026 2029 2032 2 335 2038 _= LEGEND: <br /> O\PGONP C MMON PATH F <br /> g" V`k", P +III 70RZ7 7PTH OF EGRESS TRAVEL <br /> 2003 2 0 41 2009 2010 2015 2 116 202, 2022 2027 2028 2033 2 334 2039 EXITACCESS TRAVEL DISTANCE <br /> OCCUPANCY <br /> ROOM USE <br /> RM ME 101-ROOM NUMBER <br /> A <br /> B 200 SF ROOM AREA <br /> a 1:150 1.3 OL OCCUPANT LOAD <br /> 3 OCCUPANT LOAD FACTOR <br /> g IV I I n ® EXIT SIGN <br /> �� FIRE EXTINGUISHER isoicnory sraur <br /> O I\VI 1�J o ❑ C <br /> cR CARD READER <br /> EXIT PLAN & CODE <br /> �a <br /> SUMMARY <br /> \SECOND FLOOR EXIT PLAN <br /> e SCALE:1/8"=1'-0" I V <br /> 5 = <br /> 1^' ^/L <br /> 3 $ ©2--a 111 crs,LLc <br /> 8 L City of Everett Permit Services <br /> EVERETT Reviewed for Permit 01/09/2025 <br />
The URL can be used to link to this page
Your browser does not support the video tag.