T/I 4,107 SF NEW WALLS, FINISHES, CEILINGS, NO CHANGE IN USE
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TDEMOLITION RCP KEYNOTES: N O DEMOLISH EXISTING CEILING TILE AND GRID AS INDICATED.REFER TO REFLECTED <br /> CEILING PLAN FOR NEW LAYOUT.SALVAGE EXISTING ACOUSTIC TILES AND LIGHT <br /> FIXTURES FOR REUSE. <br /> O DEMOLISH EXISTING EXIT SIGN AND SALVAGE FOR RELOCATION.REFER TO <br /> REFLECTED CEILING PLAN FOR LOCATION OF NEW EXIT SIGNS. <br /> O DEMOLISH EXISTING DECORATIVE FIXTURES. 1 <br /> RCP KEYNOTES: <br /> NEW O NEW CEILING TILE AND GRID TO MATCH EXISTING GRID AND TILES.ALIGN NEW T ,p <br /> LAYOUT TO EXISTING GRID. i (=` <br /> O O O2 REFER TO HEADER DETAIL PER STRUCTURAL. Y <br /> N <br /> ° REFLECTED CEILING SHEET NOTES: W <br /> 1 <br /> z <br /> '1D '1D �p '1D O O BUILDING SYSTEMS C3 j <br /> 3 1. MODIFY EXISTING SYSTEMS AS REQUIRED BY SCOPE OF NEW WORK,THE BUILDING \ C 00 <br /> CODES IN EFFECT,AND DESIGN/CONSTRUCTION STANDARDS FOR THE SUBJECT N <br /> 0 • - BUILDING INCLUDING,BUT NOT LIMITED TO HVAC,PLUMBING,ELECTRICAL, Q Q <br /> COMMUNICATIONS,CONVEYANCE,FIREISMOKE PROTECTION,AND FIRE ALARM Z� <br /> SYSTEMS. +L+ <br /> 2. ARCHITECTURAL FEATURES AND LIGHTING LOCATIONS TAKE PRECEDENCE OVER N O1 <br /> _E OTHER ELEMENTS AND SYSTEMS.COORDINATE THE WORK OF ALL TRADES TO j <br /> ENSURE CLEARANCES FOR EQUIPMENT,FIXTURES,DUCTS,PIPING,AND ETC.AS 011� d <br /> —r--1—� 2 NECESSARY TO MAINTAIN THE FINISHED CEILING AND LIGHTING HEIGHTS AND p a)� <br /> LL LAYOUTS INDICATED IN CONSTRUCTION DOCUMENTS.NOTIFY ARCHITECT OF ANY 03 <br /> -6-� �_ _ __ CONFICTS WITH ARCHITECTURAL ELEMENTS OR LIGHTING,AND COORDINATE WITH <br /> ARCHITECT AS REQUIRED.FAILURE TO COORDINATE CONFLICTS WILL NOT WAIVE <br /> RESPONSIBILITY TO DELIVER THE FINAL DESIGN INTENT AS PRESENTED IN THE <br /> -r--1- EXIST CONSTRUCTION DOCUMENTS. <br /> -6"VI 3. VERIFY FIELD CONDITIONS AND LOCATIONS OF ALL BUILDING SYSTEMS AND <br /> COMPONENTS.INSTALL NEW AND/OR MODIFY EXISTING SYSTEMS AND COMPONENTS T E R RA P 0 W E R <br /> TO COMPLETE WORK AS REQUIRED IN THE CONSTRUCTION DOCUMENTS. <br /> 4. THE INTENT AT OPEN TO STRUCTURE CEILING AREAS IS TO KEEP THEM AS ORDERLY <br /> AS POSSIBLE,INCLUDING BUT NOT LIMITED TO HVAC,PLUMBING,CONDUIT,WIRING, BUILDING A <br /> FIRE PROTECTION AND EQUIPMENT AND FIXTURES.INSTALL OPEN TO STRUCTURE <br /> - - - - -- u ELEMENTS PARALLEL TO ADJACENT SURFACES AND FABRICATE ALL TURNS AT 90 FLOOR 2 <br /> DEGREE ANGLES.INSTALL WIRING IN LEAST VISIBLE AREAS,ADJACENT TO .I <br /> — DUCTWORK WHERE POSSIBLE. 3315 SEAWAY BLVD. <br /> - _ - - 5. SUBMIT GRILLE,THERMOSTAT,LIGHTING AND OTHER FIXTURE AND ELEMENT <br /> LAYOUTS TO THE ARCHITECT FOR REVIEW PRIOR TO ORDER PLACEMENT. EVERETT, WA 98203 <br /> 6. PROVIDE SOUND BOOTS AT ALL FULL HEIGHT ENCLOSED ROOMS AT RETURN AIR <br /> -L-J-- GRILLES,AND VAVS LOCATED IN PRIVATE OFFICES AND MEETING ROOMS. <br /> I--I ---- <br /> LIGHT FIXTURES <br /> 7. VERIFY CODE COMPLIANCE OF ALL EXISTING LIGHTING FIXTURES AND ASSOCIATED <br /> SEISMIC BRACING RESTRAINTS.FIXTURES FOUND NOT IN COMPLIANCE MAY BE <br /> REQUIRED BY THE JURISDICTION TO BE MODIFIED AND/OR REPLACED WITH <br /> EQUIVALENT FIXTURES AS REQUIRED BY CURRENT BUILDING AND/OR ENERGY <br /> CODES. <br /> 8. PROTECT EXPOSED LIGHT FIXTURES AND OTHER ELEMENTS FROM DAMAGE AND DESIGN JPC <br /> SOILING DURING CONSTRUCTION.REFER TO MANUFACTURER RECOMMENDATIONS DRAWN TSJ <br /> FOR PROTECTION DURING CONSTRUCTION. <br /> n I I n ^ 9. RE-LAMP ALL EXISTING TO REMAIN FIXTURES TO MATCH NEW FIXTURES, CHECKED AN <br /> \Y' IV LIGHTING CONTROLS NO. 24-0035 <br /> 10. ALL ENCLOSED ROOMS AND FIXTURE TYPES SHALL BE SWITCHED SEPARATELY. <br /> CONFIRM CONTROL SYSTEM CONFIGURATION WITH OWNER,TENANT AND <br /> ARCHITECT.PROVIDE ZONED LIGHTING CONTROL OF OPEN OFFICE AREAS AS <br /> SECOND FLOOR DEMOLITION REFL. CLG. PLAN REQROPRIAE.UIRED BY UBMIDE NSWITCH LOCATIONS <br /> ARCHITECTNTS FRREVAS <br /> APPROPRIATE.SUBMIT SWITCH LOCATIONS TO ARCHITECT FOR REVIEW AND <br /> _ CONFIRMATION. <br /> SCALE:1/8"=1'-0" 11. EGRESS LIGHTING SHALL BE DESIGNED BYA LICENSED ELECTRICAL ENGINEER <br /> BASED ON FINAL APPROVED LIGHTING PLANS AND THE CURRENT CODES IN EFFECT. <br /> IT SHALL REMAIN THE SOLE RESPONSIBILITY OF THE ENGINEER TO COMPLETE A <br /> SCOPE OF WORK THAT FULFILLS ALL EGRESS LIGHTING REQUIREMENTS.FINAL <br /> EGRESS LIGHTING QUANTITIES AND LOCATIONS ARE SUBJECT TO APPROVAL BY <br /> BUILDING AND FIRE INSPECTOR'S FIELD PLACEMENT DETERMINATION. <br /> CEILINGS <br /> 12. SUSPENDED CEILING COMPONENTS SHALL MATCH ADJACENT EXISTING <br /> COMPONENTS AND BE OF CONSISTENT MANUFACTURER WHERE NEW IS 6389 REGISTERED <br /> SUPPLEMENTING EXISTING.FURNISH AND INSTALL ALL ASSOCIATED TRIM AND <br /> SEIS IC BRACING AS REQUIRED. ARCHITECT <br /> 13 A. LIGHT FIXTURES,NEW SPRINKLER HEADS AND OTHER CEILING ELEMENTS SHALL BE CE <br /> CENTERED THE SECTION OF INDIVIDUAL CEILING TILES U.N.O.(EXIST. <br /> SPRINKLERSS TO REMAIN UNLESS CONFLICTING WITH NEW ELEMENTS). <br /> - - - 14. PROVIDE CEILING ACCESS AS REQUIRED FOR EQUIPMENT AND SYSTEM <br /> MAINTENANCE.PROVIDE ACCESS PANEL LOCATIONS AND PRODUCT DATA FOR <br /> ARCHITECTS REVIEW. MARK A.PETERSON <br /> ARE DIMENSIONED FOM TOP OF FINISHED <br /> O 0 15 FLOORT0 BOTTOM OFFNISHL SOFFITS AND CEILING HEIED GYPSUM BOARD ORCCEILNG TILE AND SHALL ALLOW STATE OF WASHINGTON <br /> FOR THICKNESS OF ALL FLOOR FINISHES. <br /> 16. VERIFY CODE COMPLIANCE OF EXISTING ACOUSTICAL CEILING GRID SYSTEMS AND <br /> O O O ASSOCIATED SEISMIC BRACING RESTRAINTS.SYSTEMS FOUND NOT IN COMPLIANCE <br /> --- MAYBE REQUIRED BY THE JURISDICTION TO BE MODIFIED AND/OR REPLACED WITH <br /> EQUIVALENT SYSTEMS AS REQUIRED BV CURRENT BUILDING CODES. <br /> O O <br /> 5.10.2024 PERMIT SET <br /> 0 • 1 9.17.2024 CD SET <br /> RCP SYMBOLS LEGEND: Qi ll.06.2024 TENANTREVISION <br /> TYPE SYMBOL MFG. DESCRIPTION <br /> SWITCH <br /> V'D <br /> �eI BLDG STD EXIT LIGHT <br /> GWB CEILING TYPE <br /> EXIST X'-X' CEILING HEIGHT <br /> '-6 VI �� DEMOLISH ACT GRID AND TILE <br /> rt fi <br /> BUILDING STANDARD 2x4 LIGHT <br /> ® EXTG BLDG STD SUSP. <br /> CEILING GRID&TILILE <br /> REUSED BLDG STD 2z4 CEILING <br /> TILE AND NEW GRID <br /> 1URO ON <br /> FRECESS <br /> IXTUREED LED DOWNLIGHT isoicn <br /> DEMOLITION RCP <br /> y ^ , PENDANT FIXTURE <br /> N I AND REFLECTED <br /> a CEILING PLAN <br /> �\ SECOND FLOOR REFL. CLG. PLAN NO DESIGNATION = EXIS REUSE TINGTORE <br /> R = RELOCATE FOR REUSE <br /> e N = NEW WOR RELOCATED(COORDINATE RELOCATED ITEMS I ^ <br /> W/ARCHITECT) _ .1 <br /> 3 ©2W4 JPC ARCHITECTS,LLC <br /> L City of Everett Permit Services <br /> EVERETT Reviewed for Permit 01/09/2025 <br />