Laserfiche WebLink
10 <br /> 9 8-B i <br /> 41 SEE TABLE 8-A.1 FOR MAX. <br /> SEE TABLE 8-A.1 FOR MAX. III MIN.12" END WALL POST SPACING 8 <br /> END WALL POST SPACING i IV CORNER RV CARPORTS <br /> 7 OFFSET /// aB 8 B <br /> o Iq <br /> 4 8-13 2 5 4 <br /> u � <br /> 8-5 < 1 <br /> III <br /> I II <br /> 8 5 B I Opp�o k,p � III ENGINEERED BY: <br /> �L� Z A&A ENGINEERING <br /> MIN.12" I p� Fj 0 \\ CIVIL-STRUCTIURAI <br /> 11, <br /> CORNER �04\ "p MIN.12"BETWEEN END WALL GABLES <br /> OFFSET I Oe�p\0 OPENINGS SCALE:NT5 <br /> 1 DRAWING INFORMATION <br /> 8_B I \�\2 ❑END WALL OVERHEAD DOOR OPENINGS 8 B <br /> SCALE:NTS j� / PROJECT: 20 WIPE <br /> SEE TABLE 8-A.1 FOR MAX. [20]GABLE BRACE /// LOCATION:STATE OF WASHINGTON <br /> END WALL POST SPACING 8-B PROJECT NO.: 711-24-1679 <br /> SEE TABLE 8-A.1 FOR MAX. 2 SHEET TITLE: <br /> END WALL POST SPACING <br /> 4 8 B END WALL FRAMING <br /> 8-B <br /> Q SHEET NO.: 8-A / 11 <br /> 6 <br /> x I <br /> a-B 5 . OAA . 1/25/24 <br /> CHECKED BY. DATE. <br /> 1 8-B <br /> LEGAL INFORMATION <br /> -ANY DUPUCATION OF THIS DRAWING IN WHOLE OR <br /> PART 15 STRICTLY FORBIDDEN.ANYONE DOING 50 WILL <br /> GABLE BRACING NOTE BE PROSECUTED UNDER THE FULL EXTENT OF THE LAW. <br /> W ( 3 -DRAWINGS VALID UP TO I YEAR FROM DATE OF ISSUE. <br /> 0 <br /> 1. GAB SEE NOTE 4 LE BRACE IS ONLY Q 8-B � 20 SEAL: <br /> REQUIRED FOR PARTIALLY OPENING SIZED \ A B U, <br /> ENCLOSED END WALLS(END P' <br /> w TO FIT WINDOW <br /> WALL POSTS ARE NOT ❑PARTIAL END WALL FRAMING 4 v W As `YJ, <br /> ANCHORED TO THE GROUND). SCALE:NTS <br /> m SERVICE DOOR(5)TO BE <br /> 2. FULLY ENCLOSED OR OPEN C� f <br /> LOCATED PER CUSTOMER TABLE&A.1:END WALL POST <br /> END WALLS DO NOT REQUIRE Z <br /> y GABLE BRAGING. REQUIREMENTS SPACING SCHEDULE <br /> a ❑END WALL SERVICE DOOR AND WINDOW OPENINGS '�MFH) <br /> d SCALE:NTS O <br /> lu END WALL FRAMING NOTES: ❑ 105 5' 5' 5' A f` <br /> 1. DESIGNS AND DETAILS SHOWN HERE ARE APPLICABLE TO BOTH REGULAR AND A-FRAME STYLE B ❑ 115 5' 5' 4.5' <br /> UILDINGS. ��� 40277 ti9 11�w <br /> «_ 2. MIN.12"CLEARANCE MUST BE MAINTAINED B ( )BETWEEN ANY TWO OPENINGS OVERHEAD DOOR OR SERVICE DOOR LISTER 1 <br /> V AND FROM CORNERS. ❑ 130 45' 4.5' 4' SSIONAL F�G <br /> ❑ 140 4.5' 4.5' 3' <br /> SERVICE DOORS AND WINDOWS CAN BE PLACED AS NEEDED. <br /> �J 4. DIAGONAL BRACES NEED TO BE ADDED FOR PARTIAL END WALL ENCLOSURES.SEE SHEET 9 FOR DIAGONAL ❑ 155 4' 4' 2.5' 1 1_09.2024 <br /> BRACE CONNECTION DETAILS. ❑165-180 3.5' 3 2' STAMP EXPIRY: c <br /> DATE SIGNED: 08-26-2024 <br />