5901 23RD DR W 2024 ZAP ENERGY Plans 2025-07-01
>
Address Records
>
23RD DR W
>
5901
>
ZAP ENERGY
>
Plans
>
5901 23RD DR W 2024 ZAP ENERGY Plans 2025-07-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/1/2025 1:51:26 PM
Creation date
6/5/2025 10:51:10 AM
Metadata
Fields
Template:
Address Document
Street Name
23RD DR W
Street Number
5901
Tenant Name
ZAP ENERGY
Permit
M2411-008
Year
2024
Notes
INSTALL ONE NEW SPLIT SYSTEM FAN COIL INDOOR UNIT
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
VIBRATION ISOLATION / SEISMIC SCHEDULE LAST UPDATED: 091824 <br /> UNIT BASIS OF DEFL BASE SEISMIC H e r m a n s o n <br /> TAG SERVES DESIGN 3 INCH TYPE RESTRAINT REMARKS <br /> NA I WALL MOUNTED HEAT PUMPS 4 10 15 Building Today,Defining Tomorrow <br /> NA DUCTWORK CABLE RESTRAINT 5,8,15 <br /> GENERAL ALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS(ELECTRICAL,WEIGHT,SIZE,ETC-)WITH APPROVED SUBMITTALS Hermanson Company LLP <br /> PRIOR TO INSTALLATION;FIELD COORDINATE FINAL LOCATION&INSTALL PER MANUFACTURERS REQUIREMENTS 1221 2nd Avenue North <br /> NOTE: CTB=COOLING TOWER BASE,CIE=CONCRETE INERTIA BASE Kent,Washington 98032 <br /> 4 INTERNAL ISOLATION PROVIDED INTEGRAL WITH UNIT Tel: (206)575-9700 <br /> 5 PROVIDE FLEXIBLE HOSES FOR PIPING CONNECTIONS AT UNIT Fax:(206)575-9800 <br /> 8 CONFIRM EQUIPMENT RPM,REFER TO"REQUIRED DEFLECTION BASED ON RPM"SPREADSHEET TO DETEREMINE PROPER DEFLECTION www.hermanson.com <br /> 10 SEISMIC RESTRAINT AS REQUIRED BY CODE AND/OR LOCAL AUTHORITY HAVING JURISDICTION OR PER SMACNA GUIDELINES* Contractor Reg g:HERMACLO05BJ <br /> *SUSPENDED EQUIP WITH IP=1.0 AND>20LBS REQUIRES SEISMIC BRACING-IF THE COMPONENT/EQUIPMENT IS RIGIDLY ATTACHED TO THE DUCT AND THE DUCT IS BRACED,THEN NO ADDITIONAL <br /> SEISMIC IS REQ'D.COMPONENTS/EQUIP>75LBS REQUIRE INDEPENDENT VERTICAL SUPPORTS AND SEISMIC BRACING.EQUIP WITH IP=1.5 AND<20LBS AND FLEXIBLY CONNECTED MAY BE OMITTED <br /> 15 DEFLECTION AS REQUIRED PER ASHRAE APPLICATIONS,CHAPTER 49 BASED ON STRUCTURE ITEM WILL BE SUPPORTED FROM(VERIFY PRIOR TO ORDER)OR AS PER APPROVED BY DESIGN ENGINEER <br /> PIPING MATERIAL SCHEDULE LAST UPDATED: 31621 LITHIUM <br /> PIPE SERVICE LOCATION I MATERIAL JOINT METHODS REMARKS <br /> COILCONDENSATE LAB <br /> ABOVE GROUND PVC SCH 40 SOLVENT CEMENTED IF NOT IN A RA PLENUM,SOLID CORE(NOT FOAM) <br /> ,_ABOVE GROUND ........ COPPER(DWV) SOLDER _ <br /> ABOVEGROUND COPPER(L OR M) PRESSFIT(52"),SOLDER(->2 <br /> 1 2" ZAP ENERGY <br /> REFRIGERANT 5901 23RD DR. W. <br /> ALL COPPER(ACR) BRAZED,PRESSFIT(MAXIPRO, PROVIDE NITROGEN PURGE IF BRAZED EVERETT, WA 98203 <br /> ZOOMLOCK OR UAL <br /> ALL PRE-INSULATED COPPER LINE SETS BRAZOOZED,ML PRESSFKIT(MAXIPRO, <br /> O C OR UAL PROVIDE NITROGEN PURGE IF BRAZED <br /> ALL PRE-INSULATED PE COMPOSITE FLEX BRAZED,PRESSFIT(MAXIPRO, IF NOT IN A RA PLENUM <br /> PIPE WITH ALUM CORE ZOOMLOCK OR UAL) <br /> 304 BRAIDED STAINLESS STEEL BRAZED,PRESSFIT(MAXIPRO, <br /> ALL 580 PSI MIN WORKING PRESSURE REQUIRED <br /> WITH PTFE LINER _. ZOOMLOCK OR EQUAL) <br /> �NtoDokti <br /> NOTE: BOLD&UNDERLINE REPRESENTS THE HERMANSON CORPORATE STANDARD MATERIAL AND JOINT METHOD FOR EACH SERVICE TYPE Oe Ode��.r`''S w <br /> MINIMUM PIPE INSULATION LAST UPDATED: 04/04/24 <br /> FLUID DESIGN I INSULATION CONDUCTIVITY NOMINAL PIPE DIAMETER INCH �gc,, 3er4v9 <br /> OPERATING CONDUCTIVITY MEAN TEMP 7 1 TO 1-1/2 TO 4 TO cCsiON,U,tip' <br /> TEMP°F RANGE RATING°F <34 "1-1/2' <4 <8 >_8 Ocrober2Z 2024 <br /> HEATING SYSTEMS' STEAM CONDENSATE HYDRONIC HOT WATER <br /> >350 0.32-0.34 250 4.5 5.0 1 5.0 1 5.0 5.0 <br /> 251-350 0.29-0.32 200 3.0 4.0 4.5 4.5 4.5 <br /> 201-250 0.27-0.30 150 2.5 2.5 2.5 3.0 3.0 <br /> 141-200 0.25-0.29 125 1.5 1.5 2.0 2.0 2.0 <br /> 105-140' 0.71-0.28 100 1.07 1.07 I.5' 1.57 1.S' ISSUE FOR PERMIT <br /> DOMESTIC HOT WATER; DOMESTIC HOT WATER RECIRCULATION3 <br /> NA 0.21-0.28 1 100 1 0.5 0.75 6 1.0 1.25 6 1.5 2.0 6 2.0 2.0 <br /> DOMESTIC COLD WATERS;HORIZONTAL RAIN LEADERS&CONDENSATE PIPE TO MAIN VERTICAL RISER CONDENSATION PREVENTION ONLY <br /> NA 0.21-0.27 75 0.5 0.5 0.5 0.5 0.5 Key Plan <br /> COOLING SYSTEMS' CHILLED WATER BRINE AND WATERSIDE ECONOMIZER SYSTEM <br /> SZ <br /> 40f0 0.21-0.27 75 0.5 0.5 1.0 1.0 1.0 <br /> <40 0.20-0.26 75 0.5 1.0 1.0 1.0 1.5 <br /> REFRIGERANT PIPING SEE CODE SCHEDULES FOR EXPOSED PIPE DAMAGE PROTECTION REQUIREMENTS <br /> IN COND SPACE 0.21-0.26 75 0.5 0.5 0.5 0.5 0.5 <br /> OUT COND SPACE 0.21-0.26 75 1.0 1.0 1.0 1.0 1.0 <br /> UNLINED <br /> STORAGE TANKS ALL SIZES R-12.56 <br /> NOTES: <br /> GENERAL ALL PIPING EXPOSED TO WEATHER TO BE PROTECTED FROM SUNLIGHT,MOISTURE,WIND AND MAINTENANCE DAMAGE <br /> AND SHIELDED FROM SOLAR DEGREDATION,ADHESIVE TAPES ARE NOT ALLOWED <br /> 1 NOT REQUIRED FOR STRAINERS,CONTROL VALVES&BALANCING VALVES ASSOCIATED WITH PIPING 1"OR LESS IN DIA. <br /> 2 TYPICAL CONDENSER WATER PIPE IN NON-ECONOMIZER SYSTEMS IS NOT INSULATED <br /> 3 SEE R403 FOR RESIDENTIAL INSTALLATIONS <br /> 4 FOR PIPING SMALLER THAN 1-1/2 INCH AND LOCATED IN PARTITIONS WITHIN CONDITIONED SPACES,REDUCTION OF <br /> INSULATION THICKNESSES BY 1 INCH SHALL BE PERMITTED,BUT NOT TO A THICKNESS OF LESS THAN 1 INCH <br /> 5 DOMESTIC HOT WATER PIPE INSULATION SHALL HAVE A MINIMUM WALL THICKNESS OF NOT LESS THAN THE DIAMETER <br /> OF THE PIPE FOR PIPE UP TO 2 INCHES IN DIAMETER.INSULATION WALL THICKNESS SHALL NOT BE LESS THAN 2 INCHES <br /> FOR A PIPE OF 2 INCHES OR MORE IN DIAMETER.NOTE THAT THIS IS PER UPC SECTION 609.11.2.IN JURISDICTIONS <br /> THAT REQUIRE DOMESTIC HOT WATER PIPING TO BE INSULATED PER THE ENERGY CODE,USE THE 105-140 ROW <br /> FROM HEATING SYSTEMS ABOVE. <br /> 6 UNFIRED TANKS USED TO STORE WATER AT TEMPERATURES ABOVE 130T SHALL INCLUDE A MINIMUM OF R-2 Revisions <br /> ADDITIONAL INSULATION FOR EVERY 10T INCREASE IN STORED WATER TEMPERATURE OVER 130'F. <br /> 7 FOR HEATED WATER CIRCULATION SYSTEMS,BOTH SUPPLY AND RETURN PIPE INSULATION SHALL BE AT MINIMUM <br /> 1 INCH THICKER THAN ROW 105-140 FROM HEATING SYSTEMS,ABOVE,EXCEPT WHERE PIPING IS CENTERED WITHIN <br /> A FRAMING CAVITY 4"DEEPER THAN THE PIPE DIAMETER THAT IS COMPLETELY FILLED WITH BATT OR <br /> BLOWN-IN INSULATION. <br /> MINIMUM DUCT INSULATION LAST UPDATED 05/02/24 - <br /> INSULATION <br /> DUCT SYSTEM DUCT LOCATION AND USE R-VALUE REMARKS - <br /> CLIMATE ZONE 4C <br /> SUPPLY AIR OR OUTSIDE THE BUIDING(OUTDOORS AND EXPOSED TO WEATHER) R-8 1 <br /> RETURN AIR <br /> SUPPLY AIR OR UNCONDITIONED SPACE(ENCLOSED BUT NOT IN THE BUILDING CONDITIONED R-6 1 <br /> RETURN AIR ENVELOPE <br /> SUPPLY AIR OR UNCONDITIONED SPACE(DUCT CONVEYS AIR THAT IS WITHIN 15"F OF THE AIR <br /> R-3.3 2 <br /> RETURN AIR TEMPERATURE OF THE SURROUNDING UNCONDITIONED SPACE) <br /> SUPPLY AIR OR IN A BUILDING ENVELOPE ASSEMBLY <br /> R-16 3 <br /> RETURN AIR <br /> WITHIN CONDITIONED SPACE(SUPPLY DUCT CONVEYS AIR THAT IS LESS THAN 55-F R-3.3 1 <br /> SUPPLY AIR OR GREATER THAN 105° 10/25/24 BDG ISSUE FOR PERMIT <br /> WITHIN CONDITIONED SPACE THAT THE DUCT DIRECTLY SERVES AND WITHIN VIEW - <br /> SUPPLY AIR (SUPPLY DUCT CONVEYS AIR THAT IS LESS THAN 55•F OR GREATER THAN 105°F) NONE 1 No. Date By Description <br /> WITHIN CONDITIONED SPACE(SUPPLY DUCT CONVEYS AIR THAT IS 55•F OR NONE 1 <br /> SUPPLY AIR GREATER AND 105°F OR LESS <br /> RETURN OR WITHIN CONDITIONED SPACE,DOWNSTREAM OF AN ENERGY RECOVERY MEDIA, R-s - Design Team <br /> EXHAUST AIR UPSTREAM OF AN AUTOMATIC SHUT OFF DAMPER <br /> RELIEF OR WITHIN CONDITIONED SPACE AND DOWNSTREAM OF AN AUTOMATIC SHUT OFF R-16 - Design BDG <br /> EXHAUST AIR DAMPER <br /> OUTSIDE AIR INSIDE CONDITIONED SPACE AND UPSTREAM OF AN AUTOMATIC >2800 CFM R-16 4 Drawn FVP <br /> SHUT OFF DAMPER <br /> OUTSIDE AIR INSIDE CONDITIONED SPACE AND DOWNSTREAM OF AN AUTOMATIC i 2800 CFM R-8 Checked DTN <br /> SHUT OFF DAMPER TO HVAC UNIT OR ROOM <br /> OUTSIDE AIR INSIDE CONDITIONED SPACE <2800 CFM R-7 5 Pre-Construction Number 21-24-27429 <br /> Construction Number <br /> NOTES: <br /> 1 SEE ENERGY CODE SECTION C403.10.1.2 FOR DETAILS Issue Date 10/25/24 <br /> 2 SEE IMC SECTION 603.12 FOR ADDITIONAL REQUIREMENTS FOR CONDENSATION CONTROL AT DUCTWORK <br /> 3 DUCT OR PLENUM IS SEPARATED FROM BUILDING ENVELOPE ASSEMBLY WITH THE MINIMUM INSULATION VALUE <br /> 4 SEE ENERGY CODE SECTION C403.10.1.1 FOR ADDITIONAL REQUIREMENTS <br /> 5 SEE EXCEPTION 1 TO SECTION C403.10.1.1 FOR ADDITIONAL DETAILS <br /> CONSTRUCTION <br /> STANDARDS <br /> - HVAC <br /> FOR CITY USE: <br /> M0.01 <br /> L City of Everett Permit Services <br /> EVERETT Reviewed for Permit 12/19/2024 <br />