My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6611 ASSOCIATED BLVD PLANS 2024 Plans 2025-07-01
>
Address Records
>
ASSOCIATED BLVD
>
6611
>
Plans
>
6611 ASSOCIATED BLVD PLANS 2024 Plans 2025-07-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/5/2025 11:22:10 AM
Creation date
6/5/2025 11:21:35 AM
Metadata
Fields
Template:
Address Document
Street Name
ASSOCIATED BLVD
Street Number
6611
Unit
PLANS
Permit
B2410-012
Year
2024
Notes
T/I - INTERIOR NON-STRUCTURAL ALTERATIONS TO EXISTING OFFICE
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
T HARDWARE SETS: N <br /> 0'M <br /> 7 7 HS-1 SINGLE NON-RATED DOOR WITH LATCHSET HS-2 SINGLE NON-RATED DOOR WITH LOCKSET <br /> 1 QTY 2 PAIR-BUTT HINGES QTY 2 PAIR-BUTT HINGES <br /> Qryi-LEVER LATCHSET OTY1-LEVER LOCKSET <br /> BLDG.STD.6'-0"X V-0"BS X 1-3/4" QTY 1-BLDG STD.DOOR STOP OTY 1-BLDG STD.DOOR STOP <br /> SC,FLUSH PANEL WOOD DOORS BLDG.STD.3'-0"X T-0"BS X 1-314" BLDG VARIER VFY .STD.T-T X 6-0"BS X 1-314" QTY 1 SET-SILENCERS OTY 1 SET-SILENCERS . ■ <br /> �\ SC,FLUSH PANEL WOOD DOORS /� SC,FLUSH PANEL WOOD DOORS W <br /> FINISH:BLDG.PAINTED WOOD � � FINISH:BLDG.PAINTED WOOD � �, EXISTING FINISH:BLDG.PAINTED WOOD HS-3 DOUBLE NON-RATED DOOR WITH LOCKSET HS4 SINGLE NON-RATED DOOR WITH PRIVACY LOCKSET <br /> DOORS AND FRAMES DOORS AND FRAMES DOORS AND FRAMES <br /> NOTE @ DOOR/RELITE QTY 4 PAIR-BUTT HINGES QTY 1-1/2 PAIR-BUTT HINGES <br /> NOTE @ DOOR/RELITE NOTE @ DOOR/RELITE QTY 1-LEVER LOCKSET WITH DUMMY TRIM ON INACTIVE LEAF QTY 1-LEVER PRIVACY LOCKSET <br /> COMBINATION:PROVIDE COMBINATION:PROVIDE COMBINATION:PROVIDE QTY 2-BLDG STD.DOOR STOP OTY 1-BLDG STD.DOOR STOP 10 <br /> METAL STUD KICKERSSUPPORTUPTO 1 p <br /> SUPPORTUPTOSTRUCT. II� 7 METAL II/ 0 METAL STUD KICKERS QTY2SET-SILENCERS QTYISET-SILENCERS N <br /> 7 FORSTABILITY. -10.1 FOR STABILITY. STRUCT. -10.1 FOR SSUPPOTABILIry.RT UP TO STRUCT. QTY 2-CLOSERS Y <br /> Ln <br /> 10.1 AT NEW <br /> E UNISEX METAL <br /> DOOR SCHEDULE:FLOOR 1 &2 � Lu <br /> AT NEW UNISEX RESTROOMS ONLY g <br /> Z v <br /> NO. TYPE FRAME HDWE RATING REMARKS REVISION Q , C> <br /> \� 00 <br /> BASE,AS SPECIFIED \l 100A EX EX EX N P <br /> 10 EX EX EX L <br /> BASE,AS SPECIFIED BASE,AS SPECIFIED ++ 102A 2A A WD HS9 <br /> N CL I-10.1 1028 E% EX EX j <br /> � <br /> ODOOR TYPE A O DOOR TYPE B O DOOR TYPE C ;04X EX EX EX a m <br /> SCALE:3/8"=1'-0" SCALE:3l8-=1'4" SCALE:3/8"=V-0" 104C EX EX EX <br /> 105 E% EX EX <br /> 108 EX EX EX <br /> 110 B WD HS-2 <br /> 112 EX EX EX <br /> 114 B WD H94 EXISTING DOOR WITH NEW <br /> HARDWARE EVERETT COMMERCE CTR A <br /> 116 B WD HS4 EXISTING OORWITHNEW <br /> HARDWARE <br /> Floor 1 &2 <br /> 119 EX EX EX <br /> 122 EX EX EX 6611 Associated Blvd <br /> 124 EX EX EX Everett,WA 98203 <br /> 125 EX EX EX <br /> 200 EX EX EX <br /> 202 E% EX EX <br /> 204 C WD HS-1 EXISTING ADJACENT DOOR TO <br /> DESIGN JPC <br /> NEW RELITE DRAWN VZ <br /> 206 C WD HS-1 EXISTING ADJACENT DOOR TO CHECKED AC <br /> NEW RELITE <br /> 208 C WD HS-1 EXISTING ADJACENT DOOR TO NO. 24-0444 <br /> NEW RELITE <br /> 210 C WD HS-1 EXISTING ADJACENT DOOR TO <br /> NEW RELITE REGISTERED <br /> 212 E% EX EX 4.CTA <br /> 214 EX EX EX216 EX EX EX LOTTE ATT ON OF WASHINGTON <br /> 218 EX EX EX <br /> BUILDING STANDARD BUILDING STANDARD 226 E% EX EX <br /> 1' <br /> WOOD VENEER FRAME TYP 11/ WOOD VENEER FRAME <br /> 2" <br /> 1 1l2' <br /> 1/2"THICK WOOD <br /> STOP <br /> DOOR PER � a � <br /> SCHEDULE _ 1/4"TEMPERED SAFETY <br /> GLASS SET WITH GLAZING <br /> TAPE AT ENTIRE <br /> PERIMETER <br /> DOUBLE STUDS AT EACH DOUBLE STUDS AT EACH <br /> SIDE OF JAMBS SIDE OF JAMBS <br /> C <br /> 1/2" SILL BELOW w <br /> wig <br /> TYR GENERAL DOOR NOTES:(AS APPLIES) <br /> SPECIFIED PARTITION SPECIFIED PARTITION 1. PROVIDE AND INSTALL DIAGONAL BRACE(TO MATCH WALL FRAMING)AT THE LATCH SIDE OF ALL NEW DOOR FRAMES,ABOVE 09.16.24 PERMIT ISSUE <br /> ACOUSTICAL SEALANT,EA ACOUSTICAL SEALANT,EA <br /> CEILING,EITHER TO ADJACENT WALL FRAMING OR TO STRUCTURE ABOVE. <br /> SHIM AS SIDE SHIM AS REQUIRED SIDE 2. GC TO COORDINATE JAMB DEPTH WITH FINISHED WALL WIDTH PRIOR TO ORDERING FRAMES. <br /> REQUIRED NOTE:VERIFY TO MATCH EXISTING BLDG STANDARD NOTE:VERIFY TO MATCH EXISTING BLDG STANDARD 3. ALL EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. <br /> 4. ALL GLAZING SHALL CONFORM TO SAFETY GLAZING REQUIREMENTS OF IBC SECTION 2406. <br /> 5. MAGNETIC HOLD OPEN DEVICES SHALL BE TIED TO BUILDING FIRE ALARM SYSTEM. <br /> 6. ALL RATED DOORS TO BE LABELED PER IBC TABLE 715.3. <br /> 7 DOOR JAMB (HEAD SIMILAR) g RELITE JAMB (HEAD SIMILAR)1'-0'SCALE:6'=1'-0" CALE:I7. THRESHOLDS AT DOORWAYS SHALL BE:MAXIMUM IN HEIGHT.PER ICC/ANSI A117.1-2009 SECTION 404.2.4. <br /> S = <br /> 8. ICC/ANSI Al 17.1-2009 SECTION 404.2.6.DOOR HARDWARE.HANDLES,PULLS,LATCHES,LOCKS 8 OTHER OPERABLE PARTS ON <br /> 112" ACCESSIBLE DOORS SHALL HAVE A SHAPE THAT IS EASY TO GRASP WITH ONE HAND 8 DOES NOT REQUIRE TIGHT GRASPING, <br /> 1 112" TYP PINCHING,OR TWISTING OF THE WRIST TO OPERATE.OPERABLE PARTS OF SUCH HARDWARE SHALL BE 34'MIN.848"MAX, <br /> 5 1/4" ABOVE THE FLOOR.WHERE SLIDING DOORS ARE IN THE FULLY OPEN POSITION.OPERATING HARDWARE SHALL BE EXPOSED 8 <br /> USABLE FROM BOTH SIDES. <br /> 9. ICC/ANSI Al17.1-2009 SECTION 404.2.8.DOOR OPENING FORCE.FIRE DOORS SHALL HAVE THE MINIMUM OPENING FORCE <br /> S DOOR PER ill"THICK WOOD 1/4"TEMPERED SAFETY ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY.THE MAXIMUM FORCE FOR PUSHING OR PULLING OPEN <br /> SCHEDULE = w STOP GLASS SET WITH GLAZING DOORS OTHER THAN FIRE DOORS SHALL BE AS FOLLOWS:1.INTERIOR HINGED DOOR:5.0 POUNDS(22.2 N) 2.SLIDING OR <br /> TAPE AT ENTIRE PERIMETER FOLDING DOOR:5.0 POUNDS(22.2 N).THESE FORCES DO NOTAPPLY TO THE FORCE REQUIRED TO RETRACT LATCH BOLTS OR <br /> ' EO +, 1" EO DISENGAGE OTHER DEVICES THAT HOLD THE DOOR IN A CLOSED POSITION. <br /> il4"TEMPERED SAFETY 10. ACTIVATION OF THE BUILDING AUTOMATIC SPRINKLER OR FIRE DETECTION SYSTEM,IF PROVIDED,SHALL AUTOMATICALLY <br /> GLASS SET WITH SHIM AS REQUIRED UNLOCK ALL ELECTRONICALLY SECURED DOORS WITHIN THE EGRESS PATHWAY.THE DOORS SHALL REMAIN UNLOCKED UNTIL <br /> GLAZING TAPE AT THE FIRE ALARM HAS BEEN RESET. <br /> w ENTIRE PERIMETER BUILDING STANDARD 11. ENTRANCE DOORS IN THE BUILDINGS WITH OCCUPANCY IN GROUP A,B,E OR M SHALL NOT BE SECURED FROM THE EGRESS <br /> WOOD VENEER FRAME SIDE DURING PERIODS THAT THE BUILDING 15 OPEN TO THE GENERAL PUBLIC. JUR Isoicnory sraMr <br /> VERIFY MINIMUM 1/8" <br /> CLEARANCE ABOVE D00- Elevations,s <br /> , <br /> '"314 ° SPECIFIED FINISH FLOORING Details & Schedule <br /> BUILDING STANDARD <br /> WOOD VENEER FRAME, <br /> BUILDING STANDARD ° <br /> NOTE:VERIFY TO MATCH EXISTING BLDG STANDARD FINISH <br /> NOTE:VERIFY TO MATCH EXISTING BLDG STANDARD <br /> r 10 DOOR/RELITE JAMB GLAZING SILL <br /> =4 o SCALE:6"=1'-0" SCALE:6" 1'-0" <br /> -4 JRC ARCHITECTS.LLC <br /> City of Everett Permit Services <br /> EVERETT Reviewed for Permit 11/07/2024 <br />
The URL can be used to link to this page
Your browser does not support the video tag.