Laserfiche WebLink
Port of Skagit SWIFT Center <br />Douglas Building <br />PBS Engineering + Environmental <br />PBS Project #41140.017 <br />PLM ASBESTOS SAMPLE INVENTORY <br />PBS Sample #Material Type Sample Location Lab Description Lab Result Lab <br />41140.017-106 Hard mudded fitting 1st floor, ceiling hatch in Northeast Layer 1: Off-white woven fibrous material NAD SATExercise Room Layer 2: White powdery material 5% Chrysotile 4% Amosite <br />41140.017-107 Hard mudded fitting on 6" Room 8 Layer 1: Off-white woven fibrous material NAD SATfiberglass straight run Layer 2: White powdery material 8% Chrysotile 3% AmositeLayer 3: Off-white woven fibrous material NADLayer 4: White powdery material NAD <br />41140.017-108 Hard mudded fitting on 6" hard Basement, west hall Layer 1: Off-white woven fibrous material NAD SATstraight run Layer 2: White powdery material 10% Chrysotile 7% Amosite <br />41140.017-109 6" hard straight run insulation Basement hall at Room 18, south Layer 1: Off-white woven fibrous material NAD SATLayer 2: White powdery material 11% Chrysotile 8% Amosite <br />41140.017-110 6" hard straight run insulation Basement, west hall Layer 1: Off-white woven fibrous material NAD SATLayer 2: White powdery material 6% Chrysotile 15% Amosite <br />41140.017-111 6" hard straight run insulation Basement, west hall at Room 19 Layer 1: Off-white woven fibrous material NAD SATLayer 2: White powdery material 12% Chrysotile 10% Amosite <br />41140.017-112 Hard mudded fitting on 4" straight run Basement, near room 18 Layer 1: Off-white woven fibrous material NAD SATLayer 2: White powdery material 10% Chrysotile 9% Amosite <br />41140.017-113 Hard mudded fitting on 4" straight run Basement, west hall at Room 18 Layer 1: Off-white woven fibrous material NAD SATLayer 2: White powdery material 13% Chrysotile 8% Amosite <br />41140.017-114 Hard mudded fitting on 4" straight run Basement, west hall at Room 19 Layer 1: Off-white woven fibrous material NAD SATLayer 2: White powdery material 11% Chrysotile 7% Amosite <br />41140.017-115 Hard mudded fitting on 4" Basement hall at Room 12 Layer 1: Silver foil NAD SAT <br />October 30, 2023 NAD - No Asbestos Detected 9 of 19