Laserfiche WebLink
Analysis Report <br />Total Lead (Pb) <br />Douglas Building Core West Wing 2nd & 3rd Fl. <br />PBS Environmental - SeattleClient: <br />214 E Galer St. Suite. 300 <br />Seattle, WA 98102 <br />Ms. Janet MurphyAttention: <br />Address: <br />Project Location:Samples Received: 6 <br />Samples Analyzed: 6 <br />Client Project #: 41140.017 <br />Batch #: 2316179.00 <br />Date Received: 10/10/2023 <br />Lab ID Client Sample # <br />Sample <br />Weight (g) <br />Results <br />in mg/Kg <br />Results in <br />percent <br />RL in <br />mg/Kg <br />Matrix: Paint <br />Method: EPA 3051/7000B <br />23097749 41140.017-Pb12 0.1983 50 720 0.072 <br />23097750 41140.017-Pb13 0.1366 73 1900 0.19 <br />23097751 41140.017-Pb14 0.2149 47 210 0.021 <br />23097752 41140.017-Pb15 0.0631 160 <160 0.016< <br />23097753 41140.017-Pb16 0.0209 480 <480 0.048< <br />23097754 41140.017-Pb17 0.0845 120 <120 0.012< <br />FAA-02 <br />ClientSampled by: <br />Yasuyuki HidaAnalyzed by: <br />Shalini PatelReviewed by: <br />10/10/2023Date Analyzed: <br />10/11/2023Date Issued: <br />Small sample size (<0.05g) for 41140.017-Pb16Comments: <br />Bench Run No:2023-1010-07 <br />mg/ Kg =Milligrams per kilogram RL = Reporting Limit <br />Percent = Milligrams per kilogram / 10000 '<' = Below the reporting Limit <br />Note : Method QC results are acceptable unless stated otherwise. <br />Unless otherwise indicated, the condition of all samples was acceptable at time of receipt. <br />Shalini Patel, Manager Metals Lab <br />page 2 of 4