Laserfiche WebLink
2 <br />3 <br />2 <br />5 <br />6 <br />7 I g I g I I I 10 I 11 <br />9 <br />F <br />E <br />� D <br />Ci <br />0 <br />N <br />0 <br />0 <br />rn <br />r- <br />L <br />0 <br />0 <br />0 <br />0► <br />0 <br />O <br />0 <br />0 <br />U) <br />w <br />0I <br />N <br />0 <br />Q <br />UI <br />ti <br />CO <br />w <br />w C <br />cn <br />J <br />J <br />L <br />w <br />2 <br />0- <br />0 <br />w <br />w <br />0 <br />Q� . <br />J <br />J <br />2 <br />w <br />w <br />w <br />¢I <br />T- <br />0 <br />4 <br />rn <br />ti <br />Un <br />, <br />6 <br />N <br />J <br />Q <br />0- B <br />U <br />Q <br />X <br />In <br />ZD <br />U <br />X <br />J <br />E: <br />a- <br />'t <br />r <br />N <br />. N <br />N <br />O <br />N - <br />00 <br />i6i <br />2 <br />w <br />Q <br />0 <br />X <br />Q A <br />z <br />w <br />V <br />co <br />C <br />w <br />E- <br />i- <br />0 <br />J <br />0- <br />ACCESSIBILITY NOTES: <br />THIS LIST IS NOT ALL INCLUSIVE. FOR CONDITIONS NOT COVERED, CONTACT THE ARCHITECT. <br />A. At least one accessible route shall be provided within the site from accessible parking spaces and <br />accessible passenter loading zones; public streets and sidewalks; and public transportation stops to <br />the accessible building or facility entrance they serve. <br />A. Carpet or carpet tiles provided on a floor surface shall be securely attached; be firm, have a level <br />loop, textured loop, level cut pile, or level cut/uncut pile texture. Maximum pile height shall be 1/2". Exposed <br />edges of carpet shall be fastened to floor surfaces and have trim along the exposed edges. <br />11B-302.3 - OPENINGS <br />A. Openings in floor or ground surfaces shall now allow passage of a sphere more than 1/2" diameter. <br />B. Elongated opening shall be placed so that the long dimension is perpendicular of the dominant direction of travel. <br />11B-303 - CHANGES IN LEVEL <br />11 B-303.2 - VERTICAL (REFERENCE FIGURE 11 B-303.2 as shown on this sheet) <br />A. Changes in level up to 1/4" maximum may be vertical and without edge treatment. <br />11B-303.3 -BEVELED (REFERENCE FIGURE 11B-303.3 as shown on this sheet) <br />B. Changes in level between 1/4" high minimum and 1/2" maximum shall be beveled with a slope no greater than 1:2 (50%). <br />2 <br />11 <br />-_ r <br />- <br />r N <br />2 <br />�� I r � -J � <br />FIGURE 11B-303.2 FIGURE 11_B-303.3 <br />VERTICAL CHANGE IN LEVEL BEVELED CHANGE IN LEVEL <br />116-304 -TURNING SPACE <br />A. The space required to make a wheelchair turn to make a 180' turn is 60" diameter to a "T-shaped" space. <br />11B-305 - CLEAR FLOOR GROUND SPACE <br />A. Minimum clear floor space for a wheelchair and occupant shall be 30" wide x 48" long. Clear floor space <br />may be positioned for forward or parallel approach. Clear floor space shall be centered on the element it serves. <br />B. One full unobstructed side of the clear floor space adjoins or overlaps an accessible route or adjoins <br />another wheelchair clear floor surface. <br />11 B-307 PROTRUDING OBJECTS <br />11 B-307.1 - GENERAL <br />A. Objects projecting from walls (for example, telephones) with their leading edges between 27" - 80" above <br />the finished floor shall protrude no more than 4" maximum horizontally into the circulation path. <br />B. Free-standing objects mounted on posts or pylons may overhang 12" maximum when located 27" minimum <br />and 80" maximum above the ground or finished floor. <br />4 ---7--;�4" MAX NO MIN. <br />LOBBY ,k--- NO MAX. <br />z <br />ti <br />N <br />11 B-307.4 - VERTICAL CLEARANCE <br />A. Vertical clearance shall be 80" high minimum room. <br />DIVISION 4 ACCESSIBLE ROUTES <br />11 B-403 WALKING SURFACES <br />11 B-403.5 - CLEARANCES <br />A. The minimum clear width for single wheelchair passage shall be 32" at a point and 36" continuously. <br />11B-403.5.1 - CLEAR WIDTH <br />A. Walkways maintain a minimum 48" width. <br />B. Walkways less than 60" wide shall have a minimum 60" x 60" landing not to exceed every 200 ft. <br />11B-403.5.3 - PASSING SPACE <br />A. The minimum clear width for two wheelchairs to pass is 60". <br />11 B-403.3 - SURFACE CROSS SLOPES <br />A. Cross slope shall not exceet 1:48. <br />11 B-403.3 - SLOPE <br />A. Running slope shall not exceet 1:20 (5%). (If slope exceets 1:20 (5%), refer to section 11 B-405 RAMPS). <br />DIVISION 5 - GENERAL SITE AND BUILDING ELEMENTS <br />116-502 - VEHICLE SPACES <br />A. Car and van spaces shall be 18'-0" long minimum. Car parking spaces shall be 9'-0" wide minimum and <br />van parking spaces shall be 12'-0" wide minimum, shall be marked to define the width and shall have an <br />adjacent aisle complying with Section 11 B-502.3. <br />Exception: Van parking spaces shall be permitted to be 9'-0" wide minimum where the access aisle is 96" <br />wide minimum. <br />B. Parking access aisles shall be 5'-0" wide minimum and extend the length of the parking stall they serve. <br />Access aisles must adjoin an accessible route. <br />C. Surface slope shall not exceet 1:48 in all directions. <br />D. Provide minimum vertical clearance of 98" at accessible parking spaces, access aisles and along <br />at least one vehicle access route to such spaces from site entrances and exits. <br />11B-502.6 - MARKING OF PARKING SPACES <br />A. Each accessible parking space must have an individual vertically mounted sign. Required van accessible <br />spaces must be designated and <br />shall have an additional sign or additional language stating "Van Accessible". <br />B. Characters and symbols on such signs shall be located 80" minimum above the ground, or 36" if wall mounted. <br />11 B-405 - RAMPS <br />11 B-406 - SLOPE OF CURB RAMPS (REFERENCE FIGURE 11 B-406.2.2 & 406.3.2 as shown on this sheet) <br />A. Slopes of curb ramps shall not exceet 1:12 gradient (8.33%). <br />Note: Maximum cross slope of 1:48 at all ramps and level surface areas. <br />B. Maximum slopes of adjoining gutters, road surface immediately adjacent to the curb ramp, or accessible <br />route shall not exceet 1:20 (5%). <br />1126.5, PART 2 - WIDTH OF CURB RAMPS (REFERENCE FIGURE 11 B-406.2.2 & 11 B-406.3.2 as shown on this sheet) <br />A. The minimum width of a curb ramp shall be 487, exclusive of flared sides. <br />11276.5, PART 3 - SIDES OF CURB RAMPS (REFERENCE FIGURE 11 B-406.2.2 & 11 B-406.3.2 as shown on this sheet) <br />A. If a curb ramp is located where pedestrians must walk across the ramp or where it is not protected by <br />handrails or guardrails, it shall have flared sides; the maximum slope of the flare shall be 1:10 (10%). <br />� Q&„ <br />Adjoining Slope Shall <br />1% <br />/ Not Exceed 1:20 <br />landing to be <br />at least as <br />Flared sides 1:10 max slope. <br />wide as curb <br />ramp <br />4V' Min. <br />- <br />r- I ;,;,' <br />'-- <br />slope <br />, r -_, ,r" k. -%, i <br />',1 - J, , , n ♦ , <br />S- ' ,'fi <br />, J <br />t <br />- R, 7/ <br />slope ; - _ .- <br />Ramp (1:12 Max. Slope) shall have <br />. <br />detectable warnings with <br />11 i �- <br />contrasting color, see Fig. 11 B-406 <br />CBC and Fig 11 B-705.1 as shown <br />on this sheet <br />FIGURE 11 B-406.2.2 <br />STANDARD RAMP <br />-------, <br />Detectable Warning with <br />contrasting color, see Fig. <br />11 B-406 CBC and Fig. 11 b-705.1 <br />as shown on this sheet--- <br />/ i" ... ... ... � <br />Adjoining Slope Shall <br />Not Exceet 1:20 <br />-_,t <br />- �Cl, -i , ' a -- $ c- - <br />:5�, , .I- , - . .- _ - <br />'i 9 <br />48" Mire -- <br />FIGURE 11 B-406.3.2 <br />PARALLEL TO CURB <br />48" Min. <br />Location of Typical Parking <br />Access Aisle <br />Ramps (1:12 Max. Slope) <br />a- <br />LO <br />M <br />CV <br />A <br />15" at top <br />.9" at base <br />TYPICAL PLAN <br />FIGURE 11 B-705.1 <br />TRUNCATED DOMES <br />0.2" HT. <br />1 <br />- ---- Tapered edges <br />where exposed <br />TYPICAL SECTION A -A <br />11 B-503 - PASSENGER LOADING ZONES <br />11 B-503.5 - GENERAL + VERTICAL CLEARANCES <br />A. Passenger loading zones shall provide an access aisle at least 60" wide minimum and 20 ft long minimum <br />adjacent and parallel to the vehicle pull-up space. Vehicle standing spaces and access aisles shall be at the same <br />level as the vehicle pull-up space they serve. Changes in level are not permitted. Exception: slopes not sleeper than <br />1:48 shall permitted. <br />B. Provide minimum vertical clearance of 114" at accessible passenger loading zones and along at least one <br />vehicle access route from site entrances and exits. . <br />11B-406.5.9 - DIAGONAL CURB RAMPS <br />A. If diagonal curb ramps have returned curbs or other well-defined edges, such edges scall be parallel to the <br />direction of pedestrian flow. The bottom of diagonal curb ramps shall have 48" minimum clear space. If diagonal <br />curb <br />ramps are provided at marked crossings, the 48" clear space shall be within the markings. If diagonal curb ramps <br />have flared sides, they shall also have at least a 24" long segment of straight curb located on each side of the <br />curb ramp and within the marked crossing. <br />11 B-406.6 ISLANDS <br />A. Any raised islands in crossings shall be cut through level with the street or curb ramps at both sides. The <br />clear width of the accessible route at islands shall be 60" wide minimum. <br />11 B-406 - CURB RAMPS, BLENDED TRANSITIONS AND ISLANDS <br />11 B-406.1 - GENERAL <br />A. Curb ramps, blended transitions and islands on accessible routes shall comply with Section 11 B-406. <br />11B-406.5.2 - CURB RAMP WIDTH <br />A. The minimum clear width of a ramp shall be 48". <br />Note: Maximum cross slope of 1:48 at all ramps and level surface areas.) <br />11 B-406.3.1 - CURB RAMP SLOPE <br />A. The running slope of the curb ramp segments shall be in -line with the direction of the sidewalk travel. Ramp <br />runs shall have a running slope not steeper than 1:12. <br />11B-406.5.3 - CURB RAMP LANDINGS <br />A. Level landings required at top of each ramp. The slope of the landing in all directions shall be 1:48 maximum. <br />(REFERENCE FIGURE 11B-406.2.2 & 11B-406.3.2 as shown on this sheet) <br />11 B-405 - RAMPS <br />11B-405.1 - GENERAL <br />A. Ramps on accessible routes shall comply with section 11 B-405. <br />1 1 B-405.7.2.1 - SIZE TOP LANDING <br />A. Top landings shall not be less than 60" wide and shall have a length of 60" in the direction of ramp run. <br />11 B-405.7.3.1 - SIZE BOTTOM LANDING <br />A. Landings at the bottomof ramps shall extend 72" minimum in the direction of the ramp run. <br />11 B-405.7.2 - WIDTH OF LANDING <br />A. At the bottom and Intermediate landings the width shall be the same as required for ramps. <br />11B-405.7.4 - CHANGE OF DIRECTION <br />A. Ramps that change direction between runs at landing shall have a clear landing 60" minimum by 72" minimum <br />in the direction of downward travel from the upper ramp run. <br />11 B-405.8 - HANDRAILS FOR RAMPS <br />A. Handrails are required at all ramps with more than a 6" rise. <br />B. Height: 34" minimum - 38" maximum above ramp surface. <br />C. The clear space between the handrail and the wall shall be 1-1/2" minimum. <br />D. Handrails shall be at each side of ramp. <br />E. Handrails shall extend 12" of level distance beyond top and bottom of ramp and parallel to the floor or ground <br />surface. The inside handrail on switchback ramps shall always be continuous. <br />11B-406.9 - EDGE PROTECTION <br />A. Edge protectino complying with Section 11 B-405.9.2 shall be provided on each side of ramp runs and at each <br />side of ramp landings. <br />11 B-303.5 - WARNING CURBS <br />A. Warning curbs shall be at least 6" in height above the walk or sidewalk surface. <br />B. Warning curbs are not required when a guard or handrail is provided with a guiderail centered 2" minimum <br />and 4" maximum above the surface of the walk or sidewalk. <br />11 B-404 DOORS, DOORWAYS AND GATES <br />11B-404.2.2 DOUBLE -LEAF DOORS AND GATES <br />A. At least one of the active leaves of doorways with two leaves shall comply with sections 11 B-404.2.3 and <br />11 B-404.2.4 <br />11 B-404.2.3 - CLEAR WIDTH <br />A. Door openings shall provide a clear width of 32" minimum, with the door open 90°. <br />1. Clear openings shall be measured between the face of the door.and opposite stop. <br />2. Openings more than 24" in depth shall provide a clear opening of 36" minimum. <br />Exception: Doors not requiring full user passage, such as shallow closets, may have a clear opening of 20" <br />minimum. <br />11 B-404.2.4 - MANEUVERING CLEARANCES AT DOORS <br />Provide level (1:50 (5%) max. slope) and clear maneuvering area at doors as follows: <br />A. Front approach pull side - 60" minimum length & 18" minimum beside strike edge 24" at exterior doors. <br />B. Front approach push side - 48" minimum length & 0" beside strike edge (12" at strike if door has both a closer <br />and a latch.) <br />. C. Hinge side approach pull side - 60" minimum width; 36" minimum beside strike edge. <br />D. Hinge side approach push side - 44" minimum width & 22" minimum beside hinge edge (48" minimum width if <br />door has both a closer and a latch.) . <br />E. Latch side appraoch pull side - 60" minimum width and 24" minimum beside strike edge (54" minimum width if <br />door has a closer). <br />F. Latch side approach push side - 44" minimum width and 24" minimum beside strike.edge (48" minimum width if <br />door has a closer). <br />11 B-404.2.5 - THRESHOLDS AT DOORWAYS <br />A. The height of the threshold shall be at a maximum of 1/2" above the floor/landing. <br />B. Change in level between 1/4" and 1/2" shall be beveled with a slope no greater than 1:2 (50%) slope. <br />Note: The threshold shall have vertical edges no greater than 1/4". <br />11B-404.2.9 - DOOR OPENING FORCE <br />A. The maximum force for pushing or pulling open a door shall be as follows: <br />1. Fire doors shall have the minimum opening force allowable by the appropriate administrative authority, not <br />to exceed 15 Ibf. <br />2. Other doors: <br />. I a. Exterior hinged doors: 5 Ibs maximum <br />b. Interior hinged doors: 5 Ibs maximum <br />c. Sliding or folding doors,: 5 Ibs maximum <br />11 B-404.2.8.1 - DOOR CLOSERS <br />A. If a door has a closer, then the sweep period of the closer shall be adjusted so that from an open po <br />sition of <br />900, the time required to move the door to a position of 120 from the latch is 5 seconds. <br />11 B-404.2.7 - DOOR HARDWARS <br />A. Handles, pulls, latches, locks, and other operating devices shall have a shape that is easy to grasp. with one <br />hand and does not require tight grasping, tich pinching, or twisting of the wrist to operate. <br />B. Hardware required for accessible door passage shall be centered between 34" minimum and 44" maximum <br />above finish floor. <br />C. Lever -operated mechanisms and push-pull activating -type mechanisms are acceptable designs. <br />11 B-404.2.10 - DOOR SURFACE <br />A. Swinging door and gate surfaces within 10" of the finish floor or ground measured vertically shall have a smooth <br />surface on the push side extending the full width of the door or gate. <br />11 B-602 - DRINKING FOUNTAINS <br />11B-602.4 - SPOUT HEIGHT (REFERENCE FIGURE 11B-313 as shown on this sheet) <br />A. Accessible spouts shall be no higher than 36" , measured from the floor or ground surface to the spout outlet. <br />B. In addition to the accessible drinking unit, at least one drinking fountain shall be at a standard height (38" <br />minimum and 43" maximum above finish floor). A "hi -low" fountain will accommodate both requirements. <br />11 B-602.2 - CLEARANCES + ALCOVES (REFERENCE FIGURE 11 B-36 as shown on this sheet) <br />A. Wall and post -mounted cantilever fountains shall have clear knee space as follows: <br />1. Minimum 27" high (from apron bottom to floor) minimum 30" wide, and 18"-19" deep. <br />2. A clear floor space allowing a forward approach to the unit shall be provided. The minimum clear floor space <br />shall be 30" wide x 48" deep. <br />11 B-602.9 - PEDESTRIAN PROTECTION <br />A. Drinking fountains shall be located within alcoves, wing walls or otherwise positioned not to encroach into <br />pedestrian ways. The minimum alcove size shall be 32" wide minimum x 18" deep minimum. <br />11B-211.2 -ACCESSIBLE DRINKING FOUNTAIN REQUIREMENTS <br />A. Where only one drinking fountain area is provided on a floor, there shall be a drinking fountain that is accessible to <br />individuals who use wheelchairs and one that is accessible to those who have difficulty bending or stooping. This can <br />be accommodated by use of "hi -low" fountains. <br />B. Where more than one drinking fountain is provided on a floor, 50% of those provided must be wheelchair <br />accessible. . <br />DRINKING FOUNTAIN HEIGHTS AND CLEARANCES: E.Q. E.Q. <br />11 8" TO9" EQUIPMENT 48"MIN. <br />PERMITTED IN 6" MAX. <br />SHADED AREA <br />z o% C � ; o <br />, <br />J , J J ' <br />X U �; U U +� <br />Z <t r <br />';,� Z L, ; Z Z t- <br />_� � i <br />f-- GU - <br />EL 1, <br />­�,7 �-- <br />---- NCV co 11 - <br />co 14�- "I <br />- co M ,-, <br />-F-17 <br />' 4jr I:, <br />- 1�- 7- l _ _ <br />Y ' <br />11 11 <br />i , / <br />48" MIN. 11* I <br />'� , �_- <br />8" MIN. 8 <br />KNEE CLR. � � MAX. _ 18" MIN. Q <br />TOE CLR. 9 <br />17" MIN.. ~ <br />DEPTH � 0 . <br />FREE STANDING RECESSED = = HI -LOW <br />SIDE ELEVATION (IN PLAN) (IN PLAN) m 0 (IN ELEVATION) <br />FIGURE 11 B-3B <br />11 B-604 - WATER CLOSETS AND TOILET COMPARTMENTS <br />118-604A - HEIGHT OF WATER CLOSET (REFERENCE FIGURE 100 as shown on this sheet) <br />NOTE: <br />At alcoves deeper than 24" additional 6" maneuvering clearance is required. At "hi -low" type fountains, center the 30" x 48" clear floor space on the <br />"LOW" fountain fixture. <br />A. The height to the top of the toilet seat shall be 17" minimum -19" maximum from the finished floor. <br />Note: The dimension is measured from the floor to the top of a 2" maximum high toilet seat. <br />B. Seats shall not be sprung to return to a lifted position. <br />11 B-604.5 - GRAB BARS (REFERENCE FIGURE 100 as shown on this sheet) <br />A. For water closets not located in toilet stalls, the following grab bars shall be provided: <br />1. Side wall: minimum 42" long, 12" minimum from back wall. <br />2. Rear wall: minimum 36" long, measured from the center line of water closet to 12" minimum at one end of <br />grab bar and 24" minimum on the other end of the grab bar. <br />Note: The grab bars are measured 33" minimum and 36" maximum above finish floor measured to the top of of the griping surface. <br />11B-604.4 - FLUSH CONTROLS (REFERENCE FIGURE 100 as shown on this sheet) <br />A. Controls shall be 44" maximum above the finish floor. <br />B. Lever controls or flush valves shall be mounted on the wide side of toilet areas. <br />C. The force required to activate controls shall be no greater than 5 Ibf. <br />D. Controls shall be operable with one hand and shall not require tight grasping, pinching, or twisting of the wrist. <br />Note: Controls shall be hand operated or automatic. <br />11 B-604.7- TOILET TISSUE DISPENSERS (REFERENCE FIGURE 100 as shown on this sheet) <br />A. Toilet paper dispensers shall be installed on the side wall, a minimum 19" above the floor to centerline of dispenser. <br />Note: Dispensers that control delivery or do not permit continuous paper flow shall not be used. <br />B. Centerline of dispenser shall be 7" minimum and 9" maximum from the front of the toilet <br />1 1 B-604.8.2.2 - DOORS AT WATER CLOSET COMPARTMENT(S) <br />A. Toilet stall doors shall have an automatic -closing device and shall have clear, unobstructed opening width of 32" when located <br />at the end and 34" when located at the side with the door located at 900 from its closed position. <br />11B-604.9.1 - SIZE AND ARRANGEMENT AT TOILET STALLS (REFERENCE FIGURE 100 as shown on this sheet) <br />A. Toilet stalls may be arranged to provide either a left or a right handed approach. <br />SINGLE ACCOMODATION TOILET FACILITY: ACCESSIBLE WATER CLOSET COMPARTMENT <br />FLUSH <br />ACTIVATOR <br />2 17" TO 18" ON WIDE 18" MIN. , <br />CN SIDE <br />0 <br />Z-�- - ] , -- ­- ,,\ <br />I T <br />7T, \ <br />t <br />L0 - <br />, <br />a ' , <br />2-7 <br />z <br />Cy 11 ME t <br />--,� J 1J - -J1 %\ _ ! <br />so <br />a ,` <br />32" MIN. CLR. <br />18" MIN. CLR. <br />WITHIN A MULTIPLE -ACCOMMODATION TOILET <br />FACILITY: <br />� <br />17" TO 18" FLUSH <br />ACTIVATOR ON <br />CN <br />I 1 1 WIDE SIDE <br />2i ZI `� <br />J <br />Z U <br />1E z <br />:57- <br />N =. <br />M <br />1- i � . � . =T � <br />32" MIN. CLR. <br />�I \ 4" MAX. <br />18" MIN. CLR, ,X <br />,� <br />it <br />� <br />. <br />TOILET FACILITY MOUNTING AND INSTALLMENT HEIGHTS <br />W <br />o J <br />,m <br />54" MIN. <br />w U <br />6" HOLD <br />12" MAX. <br />z 0 <br />36" MIN. - ��-i <br />42" MIN. GRAB BAR <br />w <br />GRAB BAR <br />a= <br />0 <br />= <br />24" MIN. 12" MIN. <br />o�-- <br />-p- rELONGATED <br />RIM <br />AR <br />irf�clo <br />11 24" MIN. <br />TRANSFER SIDE <br />-a'0 <br />�_ . <br />TOP OF SEAT <br />2 � <br />. <br />MAX. HIGH SEAT <br />T2" <br />71 <br />o) <br />� <br />. -----K--�*-\ <br />LL��- <br />co -N <br />M -Jl\ <br />� <br />� <br />I <br />I 1­1 <br />I 1 <br />18" HOLD <br />7" MIN. 19" MAX. <br />M <br />M <br />/ <br />. <br />CE <br />� <br />I <br />I I . <br />NOTE: R ¢ <br />FIGURE 100 SHOWS MINIMUM REQUIREMENTS. SEE DEtLkV1 ON SHEET A307 FOR ENLARGED FLOOR <br />PLAN OF EXISTING PUBLIC RESTROOM CONDITIONS. Z 0 <br />-0 <br />= r- <br />11B-213.2 - MULTIPLE -ACCOMMODATION TOILET FACILTIES <br />A. If toilet stalls are provided in a toilet room or bathroom, then at least one stall shall be a "standard" accessible toilet stall <br />(for wheelchair users) complying with this Section 11 B-603. <br />B. Provide at least one ambulatory accessible compartment where six or more compartments are provided within <br />a multiple -accommodation toilet room. (This is in addition to the accessible water closet.) The provided compartment <br />shall be 36" wide with an outward swinging self -closing door and parallel grab bars complying with Section 11 B-604.5. <br />11B-605.2 -HEIGHT OF ACCESSIBLE URINALS (REFERENCE FIGURE 101 as shown on this sheet) <br />A. Urinals shall be stall -type or wall hung with a tapered, elongated rim at 17" maximum above the finished floor. The rim shall <br />extend a minimum of 131/2" from the wall. <br />11B-605.3 -CLEAR FLOOR SPACE + APPROACH (REFERENCE FIGURE 101 as shown on this sheet) <br />A. A clear floor space 30" wide x 48" deep minimum shall be provided in front of urinal to allow forward approach. <br />1. This space shall adjoin or overlap an accessible route. <br />2. Urinals installed in alcoves deeper than 24" require a maneuvering area of at least 36" minimum wide, centered on fixture. <br />11B-605.4 FLUSH CONTROLS (REFERENCE FIGURE 101 as shown on this sheet) <br />A. Controls shall be 44" maximum above the finished floor. <br />1. Controls shall be hand operated or automatic. <br />2. Controls shall be operable with one hand and shall not require tight grasping, pinching, or twisting of the wrist. <br />3. The force required to activate controls shall be no greater than 5 Ibf. <br />15„ P --- - <br />IT- <br />,_ r , a <br />`i_ <br />,..:_ - _ „ <br />48" MIN. ' T -' <br />I/ '. , <br />I <br />_ F v <br />=� <br />,; ;� <br />-,' ; = 3 <br />. \\\\\ ',! ,,1 t,a <br />- ` „i <br />z CLEAR -- <br />. - \ <br />w <br />0 a- = FLOOR . ,, ; -%- <br />,; <br />U w o r ' `"; <br />Q w "' SPACE 2-, =t \\\N _ ` - -` <br />11 \9'� <br />¢ i _ <br />¢ i <br />z W 13.5" MIN. <br />= 0 PLAN VIEW /I /I ELEVATION <br />co <br />M <br />11 B-606 - LAVATORY HEIGHT + CLEARANCES (REFERENCE FIGURE 11 B-600 as shown on this sheet) <br />A. Lavatories shall be mounted with the rim or counter surface no higher than 34" above the finished floor. <br />1. Lavatories shall extend 17" minimum from the wall. <br />2. Clearance of 29" minimum shall be provided from the finished floor to bottom of the apron. <br />3. Knee clearance of 27" minimum shall extend 8" minimum under the front of the lavatory. <br />4. Toe clearance of 9" minimum shall be provided for the full depth of the lavatory. <br />17" MAX. <br />00!� <br />0 <br />�,- Z � <br />Z 2 2E � CLEAR [ / <br />z ® 0 I O <br />FLOOR <br />o Z� 2 2 2 CD <br />SPACE <br />2. N �'' ,T m 19" MAX. <br />M0 <br />~ I r/ <br />8" MIN, 6" MAX. 48" MIN. LA <br />17" MIN. ' SIDE ELEVATION PLAN VIEW <br />,I 'I <br />FIGURE 11 B-600 <br />LAVATORY+ MIRROR MOUNTING HEIGHTS AND CLEARANCES <br />11 B-606.4 - FAUCETS <br />A. Controls shall be operable with one hand and shall not require tight grasping, pinching, or twisting of the wrist. <br />B. The force required to activate controls shall be no greater than 5 Ibf. <br />C. Acceptable faucet designs include: lever -operated, push -type, and electronically controlled mechanisms. <br />D. If self -closing valves are used, the faucet shall remain open for at least 10 seconds. <br />11B-606.5 - EXPOSED PIPES + SURFACES BENEATH LAVATORIES <br />A. Hot water and drain pipes under lavatories shall be insulated or otherwise configured to protect against contact. <br />B. There shall be no sharp or abrasive surfaces under lavatories. <br />11 B-603.3 - MIRRORS (REFERENCE FIGURE 11 B-600 as shown on this sheet) <br />A. Mirrors shall be mounted with the bottom edge of the reflecting surface 40" maximum above the finished floor. <br />11B-609.2.1 - GRAB BARS / 11B-609.3 - DIAMETER SIZE + SPACING <br />A. Grab bars with a Circular cross section to have a diameter or width of gripping surface shall be 1-1/4" to 2" maximum. <br />B. The space between grab bars and adjacent walls shall be 1-1/2" minimum. <br />11 B-609.8 - GRAB BARS - STRUCTURAL STRENGTH <br />A. Grab bars and mounting devices shall meet the following requirements: <br />1. Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 <br />pounds is applied at any point on the grab bar, faster, mounting device, or supposering structure. <br />11 B-609.5 GRAB BARS - SURFACE <br />A. Grab bars and adjacent wall surfaces shall be free of sharp or abrasive surfaces and shall have rounded edges. <br />11 B-603.5 - ACCESSORIES <br />GENERAL: Where towel, sanitary napkins, waste receptacles, dispensers, other equipment and controls are provided <br />at least one of each type shall be located on an accessible route, with all operable parts, including coin slots, within 40" <br />from the finished floor. <br />11 B-602.5 - SPOUT LOCATION <br />A. Spouts shall be located at the front of the unit (15" minimum from the vertical support and 5" maximum from the <br />front edge including bumpers and the water stream from the bubbler shall have a flow in a trajectory that is parallel <br />(or nearly parallel) to the front edge of the unit. <br />1. The spout shall provide a flow of water at least 4" high minimum . <br />2. If the fountain has a round or oval bowl, the spout must be positioned so the flow of water is within 3" of the <br />front edge of the fountain. <br />11 B-602.3 - OPERABLE PARTS <br />A. The flow of water shall be activated by a manually operated system that is front mounted or side mounted and <br />located within 6" of the front edge of the fountain or an automatic electronically controlled device. Maximum <br />force to operate is 5 Ibf. <br />DIVISION 7 - COMMUNICATION ELEMENTS AND FEATURES <br />11B-703 -SIGNS <br />11B-703.1 - GENERAL <br />A. When new or additional signs and/or identification devices are provided or when existing signs are <br />replaced/altered, the new/altered signs shall comply with 11 B-703: types include: <br />1. Identification signs <br />2. Directional & informational signs <br />3. Accessibility signs <br />11 B-703.7.1 / 11 B-703.6.2 - FINISH AND CONTRAST <br />A. Characters, symbols and background of signs shall have a non -glare finish. <br />B. Characters and symbols shall contrast with their background (i.e. a light characters on a dark background or <br />dark characters on a light background). <br />11B-703.2.4 - PROPORTIONS <br />A. Visual characters on signs shall be selected from fonts where the width of the uppercase letter "O" is 60 <br />percent minimum and 110 percent maximum of the uppercase letter "I". Stroke thickness of the uppercase letter "I" <br />shall be 10 percent minimum and 20 percent maximum of the height of the character. <br />11 B-703.5.5 - CHARACTER HEIGHT <br />A. Characters on signs shall be appropriately sized according to the viewing distance from which they are to be <br />read, refer to the "Visual Character Height" table in section 11 B-703.5.5 <br />B. Pictorial symbol signs (pictograms) shall be accompanied by the verbal (i.e. text) description placed directly <br />below the pictogram. The outside dimension of this pictogram shall be a minimum of 6 inches in height. <br />C. Characters and Braille shall be in a horizontal format. <br />D. Braille shall be placed at a minimum of 3/8" and a maximum of 1/2" directly below the tactile characters, flush <br />left or centered. <br />E. When tactile text is multilined, all Braille shall be placed together below all lines of tactile text. <br />11 B-703.3 - BRAILLE (REFERENCE FIGURE 3 as shown on this sheet) <br />A. Braille dots are 1/10" on center in each cell with 2/10" space between cells, measured from the second column <br />of dots in the first cell to the first column of dots in the Second cell. <br />B. Braille dots are raised a minimum of 1/40" above the background. <br />C. Braille dots are domed or rounded. <br />11B-703.3.2 - MOUNTING LOCATION & HEIGHTS (REFERENCE FIGURE 2 as shown on this sheet for restrooms) <br />A. Where permanent identification signage are provided for rooms & spaces signs shall be located on the wall <br />adjacent to the latch side of the door. <br />Note: Where there is no wall space on the latch side, including at double -leaf doors, signs shall be placed on the <br />nearest adjacent wall. It is preferred on the right side, clear of any door swing. <br />B. Tactile signs for permanent rooms are mounted on the wall at a minimum of 48" above the finish floor to the <br />baseline of lowest tactile character and a maximum of 60" above the finish floor to the baseline of highest tactile <br />character. Provide clear floor space of 18" minimum x 18" minimum centered on the tactile characters beyond the <br />arc of any door swing between the closed position and 45' open position. <br />C. The braille baseline must be betwen 48" and 60" above the finished floor. <br />SANITARY FACILITY SIGNAGE <br />NOTE: Sanitary facilities are required to display signs in a minimum of two locations: <br />1. One type located on the doorway or entryway to the facility. <br />2. One type mounted on the wall adjacent to the latch side of the door. <br />3. 11 B-703.4.2 Restroom identification signs shall be located on the approach side of the door as one enters <br />the room or space. . <br />11 B-703 SANITARY FACILITY DOOR MOUNTED SIGNAGE <br />A. 11 B-703.7.2.6.1 (Men's) - Men's sanitary facilities shall be identified by an equilateral triangle 1/4" thick with. <br />edges 12" long and a vertex pointing upward. The triangle symbol shall contrast with the door, either light on a dark <br />background or dark on a light background. Fig. 1 as shown on this sheet. <br />B. 11 B-703.7.2.6.2 (Women's) - Women's sanitary facilities shall be identified by a circle that is 1/4" thick and 12" <br />in diameter. The circle symbol shall contrast with the door, either light on a dark background or dark on a light <br />background. Fig. 1 as shown on this sheet. <br />C. 11 B-703.7.2.6.3 (Unisex) - Unisex sanitary facilities shall be identified by a 12" diameter circle that is 1/4" thick <br />triangle superimposed within the circle. The triangle symbol shall contrast with the circle symbol, either light on a <br />dark background or dark on a light background. The circle symbol shall contrast with the door, either light on a <br />dark background or dark on a light background. Fig.1 as shown on this sheet. <br />D. 11 B-703.4.1 - The geometric symbols shall be centered horizontally on the door at a height of 60" above the <br />finish floor or ground surface measured to the center of the symbol. Fig. 2. as shown on this sheet. <br />E. 11 B-703.7.2.6.4 - The edges of the signs shall be rounded, chamfered or eased, and any corners have a <br />minimum radius of 1/8". Fig.1 as shown on this sheet. <br />11B-703 SANITARY FACILITY WALL MOUNTED SIGNAGE <br />A. The restroom identification signage (i.e. MEN'S, WOMEN'S, UNISEX.) is located on the wall adjacent to the <br />latch side of the door. Fig. 2. as shown on this sheet. <br />NOTE: Where there is no wall space on the latch side, including at double leaf door, signs shall be placed on the <br />nearest adjacent wall, preferably on the right. Fig. 2. as shown on this sheet. <br />B. Pictorial symbol signs (pictograms), if utilized in conjunction with verbal (i.e. text) identification, are located <br />directly above the verbal (i.e. text) description and the border dimension of this pictogram is a minimum of 6" in <br />height. 11 B-703.6.1 Fig.1 as shown on this sheet. <br />C. Provide clear floor space of 18" minimum x 18" minimum centered on the tactile characters beyond the arc of <br />any door swing between the closed position and 450 open position. Fig. 3, Fig. 4 as shown on this sheet. <br />11B-703.7.2 - SYMBOLS OF ACCESSIBILITY <br />1 1 B-703.7.2.1- INTERNATIONAL SYMBOL OF ACCESSIBILITY <br />A. The International Symbol of Accessibility shall be posted to identify facilities that are accessible to and <br />usable by physically disabled persons. <br />B. The Symbol of shall consist of a white figure on a blue background. <br />C. The blue color shall be equal to Color No.15090 in Federal Standard 595B. <br />Exception: The appropriate enforcement agency may approve other colors, special signs and identification to <br />compliment decor or unique design when it is determined that such an identification provides adequate . <br />direction to persons with disabilities. <br />11 B-703 - ENTRANCE SIGNS <br />A. Entrances to buildings and facilities that are accessible to and usable by persons with disabilities shall <br />be identified with a minimum of one International Symbol of Accessibility and with addition directional signs, <br />utilizing the symbol, at junctions where the accessible route of travel diverges from the regular circulation <br />path, to be visible to persons along approaching circulation paths. Fig.1 as shown on this sheet <br />1011 EXIT SIGNS <br />1 01 1.1 - TACTILE EXIT SIGNS <br />A. Each grade -level exterior exit door, that is required to comply with section 1 01 1, shall be identified by a tactile sign with the <br />word, "EXIT". Fig. 4 & 5 as shown on this sheet <br />B. Each exit door, that is required to comply with section 1 01 1, that leads directly to a grade -level exterior exit by means of a <br />stairway or ramp shall be identified by a tactile exit sign with following words as appropriate: Fig. 5 as shown on this sheet <br />1. "EXIT STAIR DOWN" <br />2. "EXIT RAMP DOWN" <br />3. "EXIT STAIR UP" <br />4. "EXIT RAMP UP" <br />C. Each exit door, that is required to comply with section 1 01 1, that leads directly to a grade -level exteriorexit by means of an exit <br />enclosure that does not utilize a stair or ramp, or an exit passageway shall be identified by a tactile exit sign with the words, <br />"EXIT ROUTE". <br />D. Each exit access door, that is required to comply with section 1 01 1, from an interior room (or area) that is <br />required to have a visual exit sign shall be identified by a tactile exit sign with the words, "EXIT ROUTE". <br />E. Each exit door, that is required to comply with section 1011, through a horizontal exit shall be identified by a tactile exit sign with <br />the words, "TO EXIT". <br />12" D. <br />O O � [ <br />U � &�, - �� F°11, <br />ICI �1111�-,-, r� co <br />MEN WOMEN UNISEX ti <br />0 0 0 <br />WALL-SIGNAGE DOOR MOUNTED SIGNAGE <br />NOTE: PICTOGRAMS AN/OR LETTERING ARE NOT REQUIRED ON DOOR MOUNTED SIGNAGE. <br />I- - - - -- - <br />i <br />:I <br />I .I <br />`� <br />i <br />i: <br />�_____ - - - <br />- --J <br />INTERNATIONAL SYMBOL OF ACCESSIBILITY <br />FIGURE 1 - SIGNAGE TYPES <br />PROVIDE CLEAR FLOOR SPACE OF 18 INCHES MINIMUM X 18 INCHES MINIMUM, <br />CENTERED ON THE TACTILE CHARACTERS BEYOND THE ARC OF ANY DOOR SWING <br />BETWEEN THE CLOSED POSITION AND 450 OPEN POSITION. <br />10" MAX. / 9" MIN. f . <br />. MOUNTED 60" AFF MAX. <br />DOOR MOUNTED SIGNAGE TO BASELINE OF <br />HIGHTEST TACTILE <br />CHARACTER <br />co <br />17 <br />7C -r--�,-- <br />RAISED EN oo o <br />CHARACTL <br />z <br />ERSN w <br />M -i <br />BRAILLE , , . , <br />0 <br />FIGURE 2 - SIGNAGE FOR SANITARY FACILITIES <br />=w <br />2m <br />PERMANENT SIGNAGE TO BE INSTALLED ON THE WALL <br />ADJACENT TO THE LATCH SIDE OF THE DOOR. <br />MOUNTING LOCATION MUST ALLOW A PERSON TO <br />APPROACH WITHOUT ENCOUNTERING PROTRUDING <br />OBJECTS OR STANDING WITHIN THE SWING PATH OF <br />THE DOOR. <br />V3�4 <br />L 0 � <br />II �ww <br />Z <br />2 = Q <br />U <br />0 ® LL = Q <br />¢ Z C)o wO V <br />00 _J w co <br />pCnJ 0ZJ <br />w ¢ q w J i- <br />m L 0-- <br />� � m � ¢ �-- <br />0 �m <br />M <br />PROVIDE CLEAR FLOOR SPACE OF 18" <br />DOOR SWING PATH MIN. X 18" MIN. CENTERED ON THE <br />TACTILE CHARACTERS BEYOND THE <br />ARC OF ANY DOOR SWING BETWEEN <br />FIGURE 3 - SIGNAGE FOR THE CLOSED POSITION AND 450 OPEN <br />PERMANENT ROOMS AND SPACES POSITION. <br />LETTERING RAISED <br />1 /32" <br />- E <br />- - i - <br />ROOM 7 <br />.234 <br />(braille grid) LITERARY BRAILLE <br />00 00 00 00 00 00 00 00 00 00 STANDARD DIMENSIONS: <br />00 00 00 00 00 00 00 00 00 00 <br />00 00 00 00 00 00 00 00 00 00 <br />a b c Dot diameter 0.059 inches <br />LETTERS AND NUMBERALS SHALL BE RAISED Inter -dot spaceing 0.090 inches <br />1/32", UPPER CASE, SAN SERIF TYPE AND. <br />SHALL BE ACCOMPANIED WITH GRADE II Horizontal separation <br />BRAILLE. RAISED CHARACTERS SHALL BE AT between cells 0.241 inches <br />LEAST 5/8" HIGH, BUT NO HIGHER THAN 2 <br />Vertical separation <br />FIGURE 3 - CONTINUED between cells 0.395 inches <br />DOOR SWING PATH e <br />FIGURE 4 - TACTILE EXIT SIGN <br />c <br />w <br />J <br />- 0 F= <br />D F= ~ U . <br />5 ~ 1E Cn <br />Lww Lw - <br />iiv = <br />11 )0 cc�< <br />LL 0 = <br />L p i F- w U <br />- w U Z Z <br />D w 2i U) <br />5 S` <br />... m PROVIDE CLEAR FLOOR SPACE OF 18„ <br />MIN. X 18" MIN. CENTERED ON THE <br />TACTILE CHARACTERS BEYOND THE <br />ARC OF ANY DOOR SWING BETWEEN <br />THE CLOSED POSITION AND 450 OPEN <br />POSITION. <br />6" (TYP.) <br />I, EQ <br />WORDING AS <br />PER <br />APPROPRIATE <br />CONDITION - - ----E %O � <br />\K--- Al I <br />DISTANCE :2� <br />BETWEEN BRAILLE = <br />AND OTHER 00 <br />TACTILE ELEMENTS <br />(BRAILLE) <br />DISTANCE FROM <br />RAISED BORDER <br />AND DECORTIVE <br />ELEMENTS z <br />co <br />`. CC 9, A I M­ I <br />PERMIT SUBMITTAL �o <br />. . <br />08/01/2022 , ( , <br />-­ I . 22-5704-01 <br />n <br />PM: KEVIN MARX <br />`') . DRAWN: RM <br />