My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9534 HOLLY DR 2024 Plans 2025-07-01
>
Address Records
>
HOLLY DR
>
9534
>
Plans
>
9534 HOLLY DR 2024 Plans 2025-07-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/1/2025 2:03:25 PM
Creation date
6/13/2025 11:21:33 AM
Metadata
Fields
Template:
Address Document
Street Name
HOLLY DR
Street Number
9534
Permit
K2412-011
Year
2024
Notes
FIRE SPRINKLERS FOR NEW DUPLEX
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Permit#: K2412-011 <br /> Builder:Bustard Custom Construction Inc Site Address: 9534 Holly or Units A B <br /> Property address:9534 Holly Dr,Everett(Arcadia Gardens Lot 3)(Duplex) Applicant: Robinson(Const)Plumbing Inc <br /> Total quantity of sprinkler heads:48(24 each unit) Application Date: 12/17/2024 <br /> JOB: BUSTARD CUSTOM HOMES Description: Fire Sprinklers for new duplex <br /> ADDRESS:9534 HOLLY DRIVE,EVERETT(LOT 3ARCHADIA GARDENS DUPLEX) Fire sprinkler SyStaM DOtaS' Review Dale: 12/18/2024 <br /> DESIGNER:KENNETH H.ROBINSON-ELMSUE <br /> CALCULATIONS FOR 25 GPM FLOW(2 HEADS) IND.LOSS NET TOTAL `Fire sprinkler <br /> p' system design per NFPA 13d(standard for houses and duplexes). <br /> a <br /> A WATER PRESSURE IN STREET 55.00 *Flre sprinkler system to be pressure tested and flow tested. EVER ETT <br /> B:SELECT PIPE SIZE:1" Everett Fire Dept.Permit Review <br /> C:DEDUCT METER S SETTER LOSS(1') 1200. 43.00 `Sprinkler piping and fittings to be C.P.V.C."Flameguard"by Spears Mfg. Status:Approved <br /> DEDUCT BACKFLOW DEVICE LOSS(NONE) 0.DO 4300 Reviewed By:kbrown <br /> D:DEDUCT HEAD LOSS FOR ELEVATION •Installation of CP.V.C.pipe and fittings to be done by manufacturer certified installers 12/18/2024 3:41:40 <br /> HEIGHT 20 X.434 LSS/FT 8.68 34.32 PM <br /> `E.DEDUCT PRESSURE LOSS FROM MAIN TO SRINKLER Sprinkler system to supply water connection for toilet s,providing"flow through"in lieu of <br /> 1-1/4" WATER SERVICE bacldlow prevention.Dead end branch lines shall be kept to no more than 10'in length.Single <br /> ITEM QUANTITY EQUIV FT.TOTAL FT. Swing check to be installed for backttow prevention at riser. <br /> PIPE: 150 1 150 <br /> ELLS: 8 2 16 <br /> R-TEES 7 3 21 •Sprinkler heads to be Victaulic FL-RES/C concealed pendant with escutcheons listing. <br /> B-TEES 3 2 6 P per <br /> TOTAL: 1. SIN#V4906 and Victa ilic sidewall V-2738. <br /> TOTAL EQUIVALENT FT.X.04 PSIIFT- 7.72 25.60 <br /> R DEDUCT PRESSURE LOSSES FOR 1-10 PIPING •Lines in attic to be protected from freezing with tent irlsulat ion(by others). <br /> FROM CONTROL VALVE TO MOST REMOTE SPRINKLER <br /> ITEM QUANTITY EQUIV FT.TOTAL FT. <br /> PIPE: 0 1 0 `Design spacing for Victaulic concealed pendant is 16'x 16'(256 square feet). <br /> ELLS: 0 9 0 <br /> R-TEES 0 1 0 <br /> B-TEES 0 8 0 •Design Density is minimum.O5 gpm/square foot <br /> TOTAL: 0 'Design area is for 2 head simultaneous flow. <br /> TOTAL EQUIVALENT FT.X.0178 PSI/FT 0 2S W <br /> F:DEDUCT PRESSURE LOSSES FORI-1/4'PIPING 'Minimum flow requirements(concealed pendant)are: <br /> FROM CONTROL VALVE TO MOST REMOTE SPRINKLER <br /> ITEM = gpm Q 7.0 psi(flat or sloped ceilings up to 8/12) <br /> QUANTITY (1)head flow 13 52 EQUIV FT.TOTAL FT. OC sloped ELLS: S 8 ei (2)head flow=13 gpm(ea)Q 7.0 psi(flat pe ceilings up to 8/12) <br /> R-TEES 7 1 7 <br /> S-TEES 4 6 24 <br /> TOTAL: 147 <br /> TOTAL EQUNALENT FT.X.0343 PSI/FT. 5,0421 21.56 <br /> F:DEDUCT PRESSURE LOSSES FOR 1"PIPING <br /> FROM CONTROL VALVE TO MOST REMOTE SPRINKLER <br /> ITEM QUANTITYEQUIVFT.TOIALFT. <br /> PIPE: 14 1 14 <br /> ELLS: 3 7 21 <br /> R-TEES 2 1 2 <br /> B-TEES 2 5 10 <br /> TOTAL: 47 <br /> TOTAL EQUIVALENT FT.X.1057 PSIIFT- 5.01 16.54 <br /> F:DEDUCT PRESSURE LOSSES FOR 3/4'PIPING <br /> FROM CONTROL VALVE TO MOST REMOTE SPRINKLER I <br /> ITEM QUANTITY EQUIV FT,TOTAL FT. �N/ <br /> PIPE: 10 1 10 I J-4 in I" I ELLS: 1 1 0 7 gLV ��+A. <br /> R-TEES 0 1 I r..................... <br /> / wbarrareu s7wre <br /> TOTAL 0 3 17 I I`A-M/Ly f�' i mare mxeT <br /> TOTAL EQUIVALENT FT,X.0683 PSI/FT. 1.52 15.02 KemW1 H.RoWn AkrWIe <br /> r 7559-0105-CE Lr 13 r <br /> RoWnwn Plumbkr9,Inc- <br /> REMAINING <br /> Y ;RO& <br /> REMAINING PRESSURE FOR SPRINKLER OPERATION 15.02 I CALCULATIONS PER NFPA I3D A.10.4.4(A)(2016 ED.) %.... ........����� <br /> � I I <br /> /� I uwme4el I / d E 903.3.1.3.1 NFPA 13D <br /> amendments.A <br /> minimum of one head <br /> A-- shall be installed on the <br /> garage side of the door <br /> leading into the <br /> (per residence from an <br /> 903.3.1.3.1 NFPA 13D +' i '0_1Sam 6 /" attached garage. EFD <br /> amendments.A <br /> minimum of one head pq U <br /> shall be installed on the z <br /> garage side of the door r(� <br /> leading into the \J <br /> residence from an ys of 3/k =y usa+47>r Z O <br /> attached garage. EFD <br /> G � m <br /> arA>> C76T G-S7 <br /> sr r<ce. lT ) Gam.` 6A4 atoEf4 O a <br /> saeeaeetunv ruao4wrr <br /> YXP044N/ z Z <br /> (S) W W <br /> 7'Y5T :D,1LVrJ z I1C <br /> LO <br /> Q Q- H ,W <br /> L1✓r1 <br /> c �G n 2 W yo <br /> vAc✓' Lr✓I,aJv QOO/N 1.1L 1.r. �C;��3 <br /> e¢A L VE <br /> o <br /> z <br /> N ° <br /> U <br /> Q <br /> /�i <br /> ° <br /> VICTAULIG V4906 CONCEALED PENDANT(22) w w LL <br /> NZ <br /> -VICTAULIC RC-RE5/5W 51DEWALL 175 DEGREE(2) z S w 3 <br /> J <br /> U �'— <br /> O -DESIGN SPRINKLER(M09T REMOTE) <br /> LU t :2() -UP OR DOWN VERTICAL PIPE L p�oz w <br /> ® RISER <br /> WATER SUFFLY/ RISER DETAIL SCALE: / =10'-O" <br /> N O SCALE SIT <br /> DE51GN 5PACING 1516'X 16'(256 SQUARE FEET) M N <br /> DENY 15.05 GPM/5QUARE FOOT 1z <br /> ALL PIPING TO BE FLAMEGUARD CPVC PER UL L15TING <br /> LL. <br /> LEGEND <br /> a <br />
The URL can be used to link to this page
Your browser does not support the video tag.