Laserfiche WebLink
ELECTRICAL LEGEND <br /> POWER RECEPTACLES&OUTLETS SERVICE GEAR•AS SHOWN ON PLANS LIGHT FIXTURES&CONTROLS ABBREVIATIONS D 2 n V Jj <br /> 9 SINGLE RECEPTACLE G CIRCUIT BREAKER PANELBOARD NOTE: LIGHTING FIXTURE SYMBOLS SHOW LENGTH,MOUNTING& A(200A) (AFTER A NUMBER)=AMPS lS 1 <br /> to DUPLEX RECEPTACLE !. LOAD CENTER EMERGENCY EGRESS INFORMATION ONLY.REFER TO FIXTURE AF(200AF)(AFTER A NUMBER)=FUSE SIZE IN AMPS J <br /> DESIGNATIONS&LIGHTING FIXTURE SCHEDULE FOR LAMP TYPE&t® DOUBLE DUPLEX RECEPTACLE L. LIGHTING CONTROL PANEL OTHER FIXTURE SPECIFICS. AFF ABOVE FINISHED FLOOR APR 11 2024 <br /> 10 DUPLEX GFCI RECEPTACLE 6 EXISTING PANELBOARD TO REMAIN 0❑ SURFACE CEILING MOUNTED DOWNUGHT AHJ AUTHORITY HAVING JURISDICTION CITY OF EVERETT <br /> k® DOUBLE DUPLEX GFCI RECEPTACLE o TERMINAL CABINET O 0 RECESSED DOWNLIGHT AL ALUMINUM Permit Services TITAN ELECTRIC <br /> ® DUPLEX RECEPTACLE MOUNTED IN CEILING O SWITCHBOARD OR MOTOR CONTROL CENTER,SIZE AS ATS AUTOMATIC TRANSFER SWITCH FULL SERVICE ELECTRICAL CONTRACTOR <br /> DOUBLE DUPLEX RECEPTACLE MOUNTED IN CEILING <br /> SHOWN ON PLANS 0� PENDANT MOUNTED FIXTURE OR CHANDELIER BKR BREAKER I_; Ica_N-1 P WAY, SUITE 205 <br /> ELLEOHE WA <br /> 8005 <br /> DUPLEX RECEPTACLE MOUNTED+4"O.C.ABOVE COUNTER OR FT DRY TYPE TRANSFORMER(SEE NOTES&RISER DIAGRAM Q Q SINGLE POINT SOURCE WALL MOUNTED FIXTURE C CONDUIT UPH, 206-633 928111 <br /> FOR SIZE)BACKSPUSH,WHEN PRESENT(U.O.N.) n WALL SCONCE CKT CIRCUIT FA. 206-374-2128 <br /> I� DOUBLE DUPLEX RECEPTACLE MOUNTED+4"O.C.ABOVE ® TRANSFER SWITCH H-0 WALL MOUNTED LONG ARM FIXTURE CL CENTERLINE <br /> COUNTER OR BACKSPLASH,WHEN PRESENT(U.O.N.) a RECESSED WALLWASHER CLG CEILING <br /> . . <br /> �t9 DUPLEX GFCI RECEPTACLE MOUNTED+4"O.C.ABOVE COUNTER UTILITY TRANSFORMER Q FLOODLIGHT OR MONOPOINT C O CONDUIT ONLY <br /> OR BACKSPLASH,WHEN PRESENT(U.O.N.) CRP CONTROL RELAY PANEL ('X <br /> METER ® SURFACE MOUNTED LINEAR FIXTURE CU COPPER J <br /> k® hk <br /> DOUBLE DUPLEX GFCI RECEPTACLE MOUNTED N .ABOVE C� SURFACE MOUNTED LINEAR FIXTURE(NARROW BODY) <br /> COUNTER OR BACKSPU O. I <br /> SH.WHEN PRESENT(U O.N ] GROUND BAR CIA DIAMETER <br /> *WP GFCI RECEPTACLE WITH WEATHERPROOF WHILE-IN-USE COVER •0 WEATHERHEAD(PLAN VIEW) ® RECESSED LINEAR FIXTURE DISC DISCONNECT I ENGINEERING <br /> 10 DUPLEX RECEPTACLE MOUNTED ON WIREMOLD PRO UTILITY POWER POLE(SITE PUN) ® PENDANT MOUNTED LINEAR FIXTURE DISP DISPOSER Consulting Electrical Engineers <br /> DOUBLE DUPLEX RECEPTACLE MOUNTED ON WIREMOLD ® GROUND ROD LOCATION WALL MOUNTED LINEAR FIXTURE DF DRINKING FOUNTAIN 19515 North Creek Parkway,Suite 302 <br /> - IUD DUPLEX RECEPTACLE MOUNTED HORIZONTALLY H—CN LINEAR STRIP FIXTURE DW DISHWASHER <br /> 0 HANDHOLE OR PULLBOX(SITE PUN) Bothell,WA Lmca 1 <br /> � LINEAR INDUSTRIAL STRIP FIXTURE E.C. ELECTRICAL CONTRACTOR 425-402-9400 offtce2°caseeng.Com <br /> Av FLUSH FLOOR OUTLET BOX WITH DEVICES SHOWN CONDUITS AND CIRCUITING WALL MOUNTED STRIP FIXTURE ECB ENCLOSED CIRCUIT BREAKER <br /> FLOOR POKE-THRU WITH DEVICES SHOWN WALL MOUNTED INDUSTRIAL LINEAR FIXTURE (E) EXISTING(USED AS SYMBOL DESIGNATION) <br /> WIRING CONCEALED IN CEILING OR WALL EMT ELECTRICAL METALLIC TUBING <br /> POWER POLE WITH DEVICES SHOWN ----WIRING CONCEALED UNDER FLOOR OR UNDERGROUND Cn� RECESSED LINEAR WALLWASHER EXTG EXISTING(USED AS ABBREVIATION IN TEXT) <br /> CONDUIT HOME-RUN C====a LINEAR UNDERCOUNTER FIXTURE EV ELECTRIC VEHICLE(CHARGER) NEL S.Cq" <br /> 0 DUPLEX RECEPTACLE WITH 1/2 SWITCHED FAAP FIRE ALARM ANNUNCIATOR PANEL S�,GR'Of WASpnc��J+� <br /> CONDUCTORS IN CONDUIT �LED COVE OR UNDER COUNTER LIGHT(LENGTH AS SHOWN t <br /> DOUBLE DUPLEX RECEPTACLE WITH 1/2 SWITCHED PHASE CONDUCTOR(S) ON PLAN) FACP FIRE ALARM CONTROL PANEL y� r• �, <br /> �T TAMPER RESISTANT RECEPTACLE NEUTRAL CONDUCTOR �Sp TRACK LIGHT(LENGTH AS SHOWN ON PLAN) FUR FLOOR <br /> GROUND CONDUCTOR F.O.I.C. FURNISHED BY OTHERS,INSTALLED <br /> SINGLE SPECIAL PURPOSE RECEPTACLE RECESSED LINEAR 2'X4'FIXTURE a <br /> �1• GROUND WIRE BY ELECTRICAL CONTRACTOR A sazTs p � <br /> VL© CEILING MOUNT DROP CORD RECEPTACLE CONDUIT BENDS TO CHANGE ELEVATION AT THIS POINT ® RECESSED LINEAR 2'x2 FIXTURE FSD FIRE SMOKE DAMPER 01f��dON�� <br /> © JUNCTION BOX WITH BLANK COVER CONDUIT STUB-UP FLIT FUTURE <br /> EMERGENCY EGRESS FIXTURES:SHADED FIXTURES REPRESENT A GEN GENERATOR 03/25/2024 <br /> I® FURNITURE SYSTEM POWER FEED.CONNECT CONDUCTORS CONDUIT BREAK CONNECTION TO EMERGENCY EGRESS LIGHTING CIRCUIT VIA UL924 GFCI GROUND FAULT CIRCUIT INTERRUPTER <br /> TO FURNITURE SYSTEM FLEX CONDUIT PROVIDED BY CONDUIT CONTINUES ELSEWHERE RELAY.DUAL CIRCUITS-NORMAL&EMERGENCY SHOWN ON PLAN <br /> (NOTED ON PUN) <br /> OTHERS.VERIFY REQUIREMENTS. AS NORMAL/EM#OR NORMAL# GND GROUND PERMIT SET <br /> IQ CLOCK OUTLET(RE,I -ED 120V RECEPTACLE) CONDUIT TO BE REMOVED EMN HH HANDHOLE <br /> KD DOORBELL ( CABLE TRAY SURFACE LINEAR FIXTURE ON EMERGENCY EGRESS CIRCUIT HTR HEATER MARCH 25,2024 <br /> �•��MULTI-OUTLET ASSEMBLY(SEE NOTES ON PLAN) ® RECESSED LINEAR FIXTURE ON EMERGENCY EGRESS CIRCUIT HWT HOT WATER TANK <br /> TELECOMMUNICATIONS SYSTEM DEVICES CONDUIT WITH BELT. FIND 0• SINGLE POINT FIXTURE ON EMERGENCY EGRESS CIRCUIT HOA HAND-OFF-AUTO <br /> FLOODLIGHT,MONOPOINT OR TRACK HEAD EGRESS kCMIL THOUSANDS OF CIRCULAR MILS Permit#: E2403-264 <br /> EQUIPMENT CONNECTIONS&CONTROLS T Site Address: 8729 AIRPORT RD <br /> KVA 1000 VOLT AMPERES Owner; AER <br /> TELEPHONE ® UNIVERSAL/CEILING MOUNTED EXIT SIGN KW 1000 WATTS MACHINISTS INC <br /> �W WALL MOUNTED TELEPHONE(VERIFY MOUNTING HEIGHT) Tenant: AM DISTRICT 751 <br /> ® EQUIPMENT CONNECTION ®[ffi] DIRECTIONAL EXIT SIGN(ARROWS INDICATE ONE OR LOP LIGHTING CONTROL PANEL App.Date: 3/28/2024 <br /> Q SINGLE GANG TELEPHONE/DATA OPENING 4 WALL MOUNTED EQUIPMENT CONNECTION TWO SIDES AND DIRECTION INDICATED) <br /> Q WAP WIRELESS ACCESS POINT rC LT LIGHT Permit Type: ELECTRICAL <br /> y MOTOR CONNECTION 13-M WALL MOUNTED EXIT SIGN LTS(LTG) LIGHTS(LIGHTING) Subtype: STANDARD ELECTRICAL PERMIT <br /> JUNCTION BOX&CONDUIT FOR FURNITURE SYSTEM r�tt Description: New Construction-Electrical <br /> TELE/DATA CONNECTIONS 0 FAN CONNECTION � EMERGENCY EXIT SIGN WITH DUAL PATHWAY HEADS LV LOW VOLTAGE <br /> a2 DATA/COMM OUTLET(NUMBER INDICATES NUMBER OF JACKS. 'B' D4 ELECTRIC WALL HEATER CONTROLLED BY WALL MCB MAIN CIRCUIT BREAKER <br /> INDICATES BLANK PLATE) MOUNTED THERMOSTAT DUAL HEAD EMERGENCY EGRESS FIXTURE MECH MECHANICAL Reviewed By: Date: /i L <br /> T <br />- ITS TELEPHONE TERMINAL BOARD-3/4"FIRE RESISTANT RECESSED STEP LIGHT MH MANHOLE ELECTRIC WALL HEATER WITH INTEGRAL THERMOSTAT Office Set _lab Site Set <br /> PLYWOOD,8' HIGH x LENGTH SHOWN ON PLAN F� RECESSED DIRECT BURIAL FLOODLIGHT MLO MAIN LUGS ONLY <br /> I <br /> ® f19"x19"TWO-POST FLOOR MOUNTED DATA -+"+ ELECTRIC UNIT HEATER ARM WALL MOUNTED DOCK LIGHT MSC MULTI-SCENE CONTROLLER - <br /> I� <br /> EQUIPMENT RACK DISCONNECT SWITCH S SINGLE POLE LIGHT SWITCH NOR NEMA 3R MW MICROWAVE CITY OF EVERETT <br /> f1R"x20"WALL MOUNTED DATA EQUIPMENT RACK a FUSED DISCONNECT SWITCH S' THREE POLE LIGHT SWITCH(NUMBER INDICATES NUMBER NIC NOT IN CONTRACT® MAGNETIC MOTOR STARTER OF POLES USED) REVIEWED FOR PERMIT <br /> AUDIOVISUAL DEVICES NREC NON-RESIDENTIAL ENERGY CODE <br /> COMBINATION STARTER AND DISCONNECT Sp DIMMER SWITCH OC ON CENTER <br /> AV AUDIOVISUAL OUTLET(SEE DRAWING NOTES FOR TYPE) 79 ENCLOSED CIRCUIT BREAKER SOS OCCUPANCY SENSOR LIGHT SWITCH OH OVERHEAD Project Title: <br /> A❑ AUDIO AUXILLIARY INPUT VFD VARIABLE FREQUENCY DRIVE Sv9 VACANCY SENSOR LIGHT SWITCH <br /> OS OCCUPANCY SENSOR <br /> ® ASSISTED LISTENING DEVICE O HAND/OFF/AUTO SWITCH SLv LOW VOLTAGE SWITCH CONTROLLED BY ROOM SENSOR PC PHOTOCELL <br /> IR INFRARED RECEIVER FOR WIRELESS MICROPHONE SYSTEM 0 START-STOP PUSHBUTTON SWITCH SLW LIGHT SWITCH SUBSCRIPTS ARE AS FOLLOWS: PNL PANELBOARD <br /> O PUSHBUTTON SWITCH NVI LV=LOW VOLTAGE,D=DIMMING PIV POST INDICATOR VALVE <br /> ❑M MICROPHONE JACK b= LOWER CASE LETTER CORRESPONDS TO LETTER AT N _,1 [ <br /> S" MOTOR RATED SWITCH FIXTURES TO BE CONTROLLED P.0.5. POINT OF SALE NEW Bl1llCllllg for: <br /> ® MICROPHONE/AUXILIARY JACK COMBINATION PLATE KD WALL MOUNTED THERMOSTAT RJ RELAY N IN LIGHTING CONTROL PANEL PP POWER POLE/POWER PACK(SEE PLAN LOCATION) <br /> RV REMOTE VOLUME CONTROLLER S#=SENSOR ZONE <br /> ELECTRIC BASEBOARD HEATER PSE PIJGET SOUND ENERGY <br /> ❑S CEILING MOUNTED SPEAKER (LENGTH&WATTAGE ON PLAN) os OCCUPANCY SENSOR PUD PUBLIC UTILITY DISTRICT <br /> AV WALL MOUNTED SPEAKER ® HEAT LAMP Q VACANCY SENSOR PV PHOTOVOLTAIC C�J�J D TAM <br /> [TV TELEVISION OUTLET F H EXHAUST FAN/HEAT LAMP COMBINATION ® PHOTOCELL LIGHT SENSOR RED RECEPTACLE(S) <br /> 5© FUTURE SMARTBOARD JUNCTION BOX -MOUNT ON WALL EXHAUST FAN/LIGHT COMBINATION ® COMBINATION VACANCY/PHOTOCELL SENSOR REF REFRIGERATOR MAY 2 1 2024 EVERETT <br /> BEHIND FUTURE EQUIPMENT AS DIRECTED ON PLANS. ` (R) RELOCATED EXISTING <br /> PROVIDE 3/4"C.O.TO ACCESSIBLE CEILING SPACE. PADDLE FAN Q SENSOR POWER PACK CITY OF EVERETT <br /> 6P 4-GANG SOUND SYSTEM INTERFACE PLATE J O PHOTOCELL AIMED NORTH,MOUNTED ON BUILDING EXTERIOR ROMTS REQUIREMENTS Permit Services <br /> SCL SEATTLE CITY LIGHT <br />_ FIRE ALARM SYSTEM EQUIPMENT S° LIGHT SWITCH WITH PILOT LIGHT SNOPUO SNOHOMISH PUBLIC UTILITY DISTRICT <br /> NOTES AND MISCELLANEOUS SYMBOLS s" KEYED SWITCH <br /> o MANUAL PULL STATION SHEET LIST <br /> C ORESTPOND IDENTIFIESSCHEDULE SPECIFIC <br /> IFI THEME ON ELECTRICAL IN ❑O LED TRANSFORMER-SHOWN AS NEEDED SPD SURGE PROTECTIVE DEVICE EO.D7 ELECTRICAL SYMBOL LEGEND&ABBREVIATIONS&SHEET LIST �TC�L��F�T. <br /> TO r� WALL MOUNTED HORN/STROBE ALARM SO SQUARE 8729 AIRPORT ROAD <br /> THAT EXPLAINS DETAILS OR FEATURES OF THAT ITEM. 8 CEILING MOUNTED HORN/STROBE ALARM �-0 ARM MOUNTED POLE LIGHT(ON SITE PLAN) SW SO BE DETERMINED E1TCH 0.02 ELECTRICAL LIGHTING S R PLAN SCHEDULE AND WSEC FORMS EVERETT,L'n r,'1 1,WA 98204 <br /> 7FF-3 MECHANICAL FLAG- DEFINES MECHANICAL EQUIPMENT AND LFJ WALL MOUNTED STROBE(ONLY)ALARM E2.02 LEVEL P1 POWER AND COMMUNICATIONS PLAN-SOUTH <br /> CORRESPONDS TO DESIGNATIONS IN MECHANICAL PLANS AND �-e-{] DUAL HEADED ARM MOUNTED POLE LIGHT(ON SITE PLAN) TTB TELEPHONE TERMINAL BOARD E2.11 LEVEL 1 POWER AND COMMUNICATIONS PLAN-NORTH <br /> SCHEDULES.CORRESPONDS TO MECHANICAL CONNECTION ( CEILING MOUNTED STROBE(ONLY)ALARM . 1-1 POST TOP AREA LIGHT TYP TYPICAL <br /> SCHEDULE IN THE ELECTRICAL SET. E2.12 LEVEL 1 POWER AND COMMUNICATIONS PLAN-SOUTH <br /> SQ SMOKE DETECTOR UC UNDER COUNTER E2.21 LEVEL 2 POWER AND COMMUNICATIONS PLAN-NORTH Sheet Title: <br /> 200 EOUIPMENT FLAG-DEFINES SPECIAL(IE.COOKING) HQ HEAT DETECTOR JIG UNDERGROUND E2.22 LEVEL 2 POWER AND COMMUNICATIONS PLAN-SOUTH <br /> EQUIPMENT ON A PLAN AND COORESPOIN TO DESIGNATIONS INTERCOM/CLOCK SYSTEM DEVICES E2.31 ROOF POWER AND COMMUNICATIONS PLAN-NORTH LET L .r+��/� T <br /> Q DUCT SMOKE DETECTOR 5 SPEAKER,CEILING MOUNTED UL UNDERWRITER'S LABORATORY E2.32 ROOF POWER AND COMMUNICATIONS PLAN-SOUTH ELECTRICAL <br /> 0 U.O.N. UNLESS OTHERWISE NOTED E3.02 LEVEL Pt LIGHTING PLAN-SOUTH <br /> IN AN EQUIPMENT SCHEDULE IN THE ELECTRICAL SET. �\ <br /> NFORMATIONREVISION OTHAUD TNHAS BEEN REVISED l FLAG -CLOUD SURROUNDS FLAG DENTIFIES 0 MAGNETIC DOOR HOLDER ^/ SPEAKER,WALL MOUNTED UTIL UTILITY E3.11 LEVEL 1 LIGHTING PLAN-NORTH SYMBOL LEGEND <br /> DIGITAL CLOCK COMBINATION OUTLET <br /> 1 THE REVISION IN WHICH THE CHANGES WERE MADE. ✓r VA VOLT AMPERES E3.12 LEVEL 1 LIGHTING PIAN-SOUTH ABBREVIATIONS <br /> OT TAMPER SWITCH v ANALOG CLOCK OUTLET E3.21 LEVEL 2 LIGHTING PLAN-NORTH &ABB r'•„AyIONS <br /> VFO VARIABLE FREQUENCY DRIVE <br /> DETAIL NUMBER -APPEARS IN FRONT OF A TITLE ON 0 FLOW SWITCH I BELL,WALL MOUNTED E3.22 LEVEL 2 LIGHTING PLAN-SOUTH <br /> O DRAWINGS WITH MORE THAN ONE ILLUSTRATION. El> BEAM SMOKE DETECTOR TRANSMITTER �5 a SPEAKER,WALL MOUNTED,EXTERIOR VS VACANCY SENSOR E3.31 ROOF LIGHTING PLAN-NORM &SHEET LIST <br /> W WATTS E3.32 ROOF LIGHTING PLAN-SOUTH <br /> 9 IDENTIFICATION SYMBOL-CROSS REFERENCES INFORMATION BEAM SMOKE DETECTOR RECEIVER VOLUME SWITCH <br /> El.l IN ONE AREA WITH A DETAIL AL #)AND SHEET(BOTTOM ) OJ FIRE/SMOKE DAMPER ,CP• CALL(PANIC)SWITCH WAR WIRELESS ACCESS POINT E4.02 LEVEL P1 MECHANICAL CONNECTIONS PLAN-SOUTH <br /> IN ANOTHER IN THE ELECTRICAL SET. FS° � wC WATER COOLER E4.11 LEVEL 1 MECHANICAL CONNECTIONS PLAN-NORTH Designed By: SHIJO <br /> FACP FIRE ALARM CONTROL PANEL W/D WASHER/DRYER E4.12 LEVEL 1 MECHANICAL CONNECTIONS PLAN-SOUTH <br /> NOTE:THESE STANDARDS APPLY ON ALL ELECTRICAL DRAWINGS C� MEDICAL EQUIPMENT E4.21 LEVEL 2 MECHANICAL CONNECTIONS PLAN-NORTH Drawn By: SH/JO <br /> UNLESS NOTED OTHERWISE. W/O WITHOUT <br /> SECURITY SYSTEM EQUIPMENT TOO NURSE CALL STATION E4.22 LEVEL 2 MECHANICAL CONNECTIONS PLAN-SOUTH Project No: 23244 <br /> Q P SYMBOLS SHOWN ON PLANS IN STANDARD(HEAVY) SSP Kph NURSE DUTY STATION WP WEATHERPROOF E4.31 ROOF MECHANICAL CONNECTIONS PLAN-NORTH <br /> p� LINE WEIGHT ARE NEW LA RELOCATED WORK. o SECURITY SYSTEM PANEL XFMR TRANSFORMER E4.32 ROOF MECHANICAL CONNECTIONS PLAN-SOUTH Date: 03l25/2024 <br /> MASTER NURSE CALL STATION <br /> °R E8.11 ENLARGED PLANS AND DETAILS <br /> IQ SYMBOLS SHOWN IN LIGHT LINE WEIGHT OR CARD READER ACCESS OUTLET QJ FILM VIEWBOX CONNECTION E9.01 RISER DIAGRAM&LOAD CALCULATIONS Sheet Number: <br /> I@ (E) DESIGNATED WITH(E)INDICATE EXISTING TO REMAIN. xa KEYPAD VB E10.01 PANEL SCHEDULES <br /> r----J O VIDEO ENTRY LIGHT NURSE CALL CEILING MOUNTED DOME LIGHT <br /> X� L---- hP SYMBOLS SD OR AS DASHED.INDICATE ITEMS TO SECURITY CAMERA I{ID "ROOM IN USE"INDICATOR LIGHT E10.02 PANEL SCHEDULES(2) <br /> BE E10.03 PANEL SCHEDULES(3) E 0•O 1 <br /> E10.04 MECHANICAL EQUIPMENT CONNECTION SCHEDULE <br />