7929 BEVERLY BLVD 2024 Plans 2025-07-01
>
Address Records
>
BEVERLY BLVD
>
7929
>
Plans
>
7929 BEVERLY BLVD 2024 Plans 2025-07-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/1/2025 2:07:03 PM
Creation date
6/13/2025 1:14:38 PM
Metadata
Fields
Template:
Address Document
Street Name
BEVERLY BLVD
Street Number
7929
Permit
B2405-041
Year
2024
Notes
SFR WITH NEW ADU BOTH CONVERT TO AFH
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
4
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
11' B A 1. PARTITION EXISTING CLOSET TO CREATE A STORAGE <br /> AREA. <br /> ® LANDING- � <br /> ALL RAILING MATERIALS SHALL BE CSL. Q <br /> 2. REMOVE EXISTING BATHTUB AND INSTALL A WALK IN Sl1V <br /> �NS <br /> H O PRESSURE TREATED WOOD <br /> -3" STORAGE SHOWER. <br /> 1 .3 Csldesigns2�Ct7ymail.com <br /> RAMP SLOPE TO MAINTAIN 6.3% <br /> 3 w GRADIENT OR LOWER 3. INSTALL GRAB BARS IN BATHROOM A&B. <br /> 4) _ RAMP VERTICAL RISE=16' <br /> CO HORIZONTAL LENGTH=1 T 5'- 7" <br /> =y a 6 x r 4. INSTALL SMOKE DETECTORS AND COMBINED FIRE SMOKE <br /> DETECTORS. <br /> c <br /> CO y <br /> 3 y s l2 1 z" 1 5. INSTALL RANGE HOOD FAN. <br /> t m 1�" 12, <br /> X 6. REMODEL IS FOR THE PURPOSE OF CONVERTING THE <br /> 5'-3" 5'-7" HOME INTO AN ADULT FAMILY HOME. <br /> v r 1 4" 3'-0" y "sf� <br /> GENERAL NOTES: <br /> 4x4 Post x4 Post <br /> -BATH 5'_y" 1. ALL SMOKE ALARMS TO BE INTERCONNECTED, <br /> 0 A Concrete ramp HARDWIRED WITH A BATTERY BACK-UP.ALL CARBON <br /> 010 SECTION VIEW w/broom finish for MONOXIDE ALARMS TO BE INTERCONNECTED, <br /> B slip resistance <br /> SCALE:NTS HARDWIRED WITH A BATTERY BACK-UP.ALARMS SHALL <br /> 3 5_6 BE INSTALLED IN SUCH A MANNER SO THAT THE <br /> =re .dow <br /> DETECTION DEVICE WARNING IS AUDIBLE FROM ALL <br /> ® 96w x36"h /41"sill 4 AREAS OF THE DWELLING UPON ACTIVATION OF A <br /> T N o height egress window SINGLE ALARM.PER IRC R330.5,R314 and R315. <br /> v 3 N o INTERIOR NON-LOAD BEARING WALLS DO NOT REQUIRE No. Description Date <br /> I 3 y 4 2 LANDING <br /> L STRUCTURAL HEADER. 1. City comment responses 7/2/24 <br /> x T 1 3 y PROVIDE INSULATION FOR ALL HOT WATER PIPING WITH 2. Clt comment responses 8/5/24 <br /> 3 rn <br /> L ro A MINIMUM THERMAL RESISTANCE(R-VALUE)OF R-3. <br /> Cl) d <br /> 12'-11 3 REFERENCE BORED OR DRILLED HOLES&FIRE <br /> ;D BLOCKING NOTATIONS ON SHEET A002. <br /> yr <br /> O 1 O 5. FIRE BLOCKING IS REQUIRED FOR ALL OPENINGS <br /> 1 AROUND VENTS,PIPES,DUCTS,CABLES AND WIRES TO <br /> F SD RESIST PASSAGE OF FLAMES AND COMBUSTION. <br /> 6. FRAME WALLS,INSTALL DOORS,WINDOWS PER AG N ES <br /> ELEVATION DETAILS ON SHEET A001 AND PER FRAMING <br /> SPECIFICATIONS ON SHEET A002. REMODEL <br /> p BATH 7. EXPOSED WALL CAVITIES SHALL BE INSULATED TO R-15 <br /> A FOR 2x4 AND R-21 FOR 2%6. <br /> CONSTUCTION NOTES. <br /> ® 1. NSTALL GRAB BARS N THE BATHROOM PER 7929 BEVERLY BLVD. <br /> 6 N a DETAIL SHOWN ON THIS SHEET. EVERETT, WA 98203 <br /> Full address to be posted at lower level 3 2�INSTALL NEW SMOKE DETECTORS. <br /> entrance:7929 Beverly Blvd,Unit B 3 y <br /> t B 3�PROVIDE COMBINED FIRE AND SMOKE DETECTOR. <br /> ID CD <br /> INSTALL A MINIMUM OF 3 FEET AWAY FROM <br /> 3 a BATHROOM DOOR. <br /> vt <br /> 24"WIDTH CLEAR WINDOW OPENING AND 36" <br /> HEIGHT CLEAR WINDOW OPENING.6.0 SF <br /> OPENABLE AREA. <br /> I <br /> 1 INSTALL 160CFM RANGE HOOD FOR LOWER LEVEL <br /> ELECTRIC RANGE. <br /> LEVEL I-FLOOR PLAN-PROPOSED <br /> SCALE: 1/4"=V-0" �N <br /> 1 1/4" MIN.-2" MAX DIA. <br /> STAINLESS STEEL GRAB STORAGE <br /> BAR PROVIDE 2X SOLID <br /> BLOCKING IN WALL AT <br /> CONTACT POINTS <br /> EDGE OF <br /> SHOWER STALI. <br /> IS BEGINNING <br /> OF SLOPED <br /> FLOOR LEGEND: <br /> WH (E)WATER HEATER LEVEL II-FLOOR PLAN-PROPOSED <br /> FUR (E)FURNACE U SCALE: 1/4"=1'-0" 547.34 <br /> NOT IN SCOPE sf <br /> 0 0 i N DECK <br /> (E)PROGRAMMABLE THERMOSTAT <br /> 6' Z, 6 6' 6' O <br /> M%I a X M XI UM M IM M C CLOSET <br /> �£ Hof E EXISTING PROPOSED PLANS <br /> N NEW <br /> CO CARBON MONOXIDE SENSOR <br /> SD SMOKE DETECTOR <br /> DIA. STAINLESS 1 1/4" MIN MAX o (E)WALLS 2x4 P.T. STRINGER Project Number <br /> o <br /> STEEL GRAB BAR 28.. N WALL L# <br /> Date 4/20/2024 <br /> 36" MIN H <br /> PROVIDE 2X SOLID 1'-6' 25"MIN.30" <br /> BLOCKING IN WALL MAX RAILING Drawn By CS <br /> AT CONTACT POINTS 12' 15' �'-4" zxasTUD @is"o.c. <br /> 36"MINI UM ONE IDE MAX. 1/2"Gypsum 2x12x16"Footer Checked By <br /> 18"OP OSnE SI E wall board 1/2"Gypsum DOOR SCHEDULE GM <br /> ° wall board (TYP.ALL) <br /> 3 DI Yx:6'-8",interior grade door A003 <br /> LANDING <br /> M M N <br /> /1 SECTION SIDE VIEW SIMPSON ABA44Z POST BASE <br /> NTS (TYP') <br /> Scale Varies <br /> GRAB BAR DETAILS INTERIOR WALL ASSEMBLY DETAIL <br />