11127 EVERGREEN WAY 2023 Plans 2025-07-01
>
Address Records
>
EVERGREEN WAY
>
11127
>
Plans
>
11127 EVERGREEN WAY 2023 Plans 2025-07-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/1/2025 2:08:12 PM
Creation date
6/13/2025 1:17:51 PM
Metadata
Fields
Template:
Address Document
Street Name
EVERGREEN WAY
Street Number
11127
Permit
M2305-118
Year
2023
Notes
REPLACE EXISTING RTU WITH NEW LIKE FOR LIKE RTU
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PACKAGED ROOFTOP AC UNIT SCHEDULE - DEMO UNIT UPDATED: 04/20/23 <br /> HEATER <br /> UNIT AREA BASIS OF SUPPLY OSA ESP IT COOLING CAPACITY SUPPLY FAN ELEC WEIGHT <br /> TAG LOCATION SERVED DESIGN CFM CFM IN WG DBIF I TOTAL MBH I SENS.MBH KW) QTY I RPM BHP SEER MCA V PH LES REMARKS <br /> AC-2 ROOF E IP.RN TRANE TM O60 2,400 0.40 55 59.0 57.0 6 CENTR 1 850 0.8 10 1 1 460 3 600 1 REMARKS: H e r m a n s o n <br /> 1 DEMO EXISTING UNIT <br /> Building Today,Defining Tomorrow <br /> PACKAGED ROOFTOP AC UNIT SCHEDULE - REPLACEMENT UNIT UPDATED: 05/23/23 Hem anson Company LLP <br /> 1221 2nd Avenue North <br /> HEATER Kent,Washington 98032 <br /> UNIT AREA BASIS OF SUPPLY MIN OSA ESP SAT COOLING CAPACITY SUPPLY FAN ELEC WEIGHT Tel:(206)575-9700 <br /> TAG LOCATION SERVED DESIGN CFM CFM IN WG DB OF TOTAL MBH I SENS.MBH KW TYPE QTY I RPM BHP HP SEER/EER MCA V/PH LBS REMARKS Fax:(206)575-9800 <br /> AC-2 ROOF EQUIP.ROOM TRANE THC067E4RI 2,000 NA 0.50 55 58.0 43.3 CENTR 1 922 0.7 1 17.2 13 1 15 46013 915 1-15 www.hennanson.com <br /> GENERAL: ALL TRADES TO CONFIRM EQUIPMENT REQUIREMENTS(ELECTRICAL,WEIGHT,SIZE,ETC...)WITH APPROVED SUBMITTALS PRIOR TO INSTALLATION;FIELD COORDINATE FINAL LOCATION&INSTALL PER MANUFACTURERS REQUIREMENTS Contractor Reg#:HDRMACLO05B1 <br /> UNIT CAPACITY RATED AT 85/67 OUTSIDE AIR DESIGN TEMPERATURES <br /> REMARKS: <br /> 1 ELECTRICAL CONTRACTOR TO PROVIDE SCCR PROTECTION DIRECTION FOR EQUIPMENT AS REQUIRED BY LATEST APPROVED VERISON OF THE NATIONAL ELECTRICAL CODE,PRIOR TO ORDER. <br /> MANUFACTURER TO PROVIDE SCCR LISTING(5 KAIC MINIMUM OR PER ELECTRICAL CONTRACTOR CALCULATION)INSIDE CONTROL PANEL AS REQUIRED BY NATIONAL ELECTRICAL CODE. <br /> 2 PROVIDE DOWNFLOW ENTHLAPHY ECONOMIZER WITH BAROMETRIC RELIEF SYSTEM <br /> 3 ECONOMIZER SHALL BE CAPABLE OF PROVIDING PARTIAL COOLING IN ADDITION TO MECHANICAL COOLING AS REQUIRED TO MEET THE REMAINDER OF THE LOAD PER ENERGY CODE SECTION C403.5.1 <br /> 4 MINIMUM UNIT EFFICIENCY TO MEET THE ENERGY CODE TABLE C403.3.2(2) <br /> 5 NOT USED om <br /> 6 NOT USED <br /> 7 REUSE EXISTING SMOKE DETECTORS,PROVIDED REPLACEMENT IF NEEDED (BY MECHANICAL)AND INSTALLED(BY ELECTRICAL)IN THE RETURN AIR. EVERETT <br /> 8 PROVIDE WITH MERV 8 FILTERS NEIGHBORHOOD FINANCIAL CENTER <br /> 9 REPLACEMENT UNIT TO BE INSTALLED ON EXISTING ROOF CURB USING CURB ADAPTOR 11127 EVERGREEN WAY <br /> 10 RECONNECT TO EXISTING CONTROLS,ADJUST OR REPLACE AS NEEDED EVERETT,WA 98204 <br /> 11 RECONNECT TO EXISTING DUCTWORK AND BALANCE TO EXISTING COOLING CAPACITY <br /> 12 HEATING&COOLING FANS/PUMPS SHALL SHUT OFF WHEN THERE IS NO CALL FOR HEATING AND COOLING IN THE ZONE PER WSEC 2018 C403.3.5.2,EXCEPT IF HEATING/COOLING FANS<0.12W/CFM <br /> 13 PROVIDE VARIABLE SPEED FAN CONTROL FOR SUPPLY FANS>5 TONS(<66%OF DESIGN SPEED AT LOW SPEED SETTING MAXIMUM)PER ENERGY CODE C403.2.11.5 <br /> 14 IF>5 TONS&ECONOMIZER PROVIDED,UNIT TO INCLUDE TWO STAGE MIN COOLING(3 STAGE IF BETWEEN 5&20 TONS,4 STAGE FOR>20 TONS)AS DEFINED BY ENERGY CODE C403.3.1.2 �NEODO11 <br /> 15 SEE STRUCTURAL CALCULATIONS FOR MOUNTING DETAILS Q�,Q�OF WASy7�F'Y�'2 <br /> 61SIE1�+O� <br /> ONAL C <br /> May 25,2023 <br /> ISSUE FOR PERMIT <br /> Revisions <br /> _05/23/23 MG ISSUE FOR PERMIT <br /> No. Date By Description <br /> Design Team <br /> Design MG <br /> Drawn FVP <br /> Checked DTN <br /> Pre—Construction Number 15-23-23919 <br /> Construction Number <br /> Issue Date 05/23/23 <br /> SCHEDULE <br /> SHEET <br /> - HVAC <br /> FOR CITY USE: <br /> M0 .02 <br />