Laserfiche WebLink
Permit#: K2409-011 „ HARBOR'S EDGE BLDG C NFPA Z M <br /> Site Address: 3620 W Mukilteo BLVD Unit E Z <br /> Applicant: Moore Fire Protection r ' •• , 13DLL <br /> Application Date:09/03/2024 0 _ Z <br /> Description: Install residential Flow-through i __- ----I SITE SPECIFICATIONS <br /> system-Harbors Edge Bldg C .- U O <br /> Review Date: 09/05/2024 AHI: City of Everett OWNER/LESSEE: < <br /> A RELATED PERMIT: B2304-042 Sage Homes Northwest <br /> OCCUPANCY TYPE: Residential 9505-19th Ave SE,Suite 118 Q J <br /> L CONST.TYPE: V-B Everett,WA 98208 1-1 <br /> EV_ER_ETT rre"r" WEST MUKILTEO BLVD. STORIES: 3 (425)609-8074 <br /> 97+00 98+00 99+00 N76U+ooe9t7'oa"E 1016.80 100+00 <br /> Everett Fire Dept.Permit Review PARCEL: 00433600004700 <br /> Status:Approved <br /> Reviewed By:kbrown GENERAL DESCRIPTION: <br /> 09/09/2024 10:43:04 New single family attached townhome.The typical and mirrored plans are both shown for <br /> AM reference.This submittal is for one plan-type only._______________ ________________________________________________-_______________-___________________________________ <br /> 0 LEGAL DESCRIPTION: <br /> _____ EDGEWATER BLK 000 D-00-LOT 47 <br /> Everett Fire Dept.Notes: <br /> i(NFPA 13D) I " <br /> FIRE FLOW <br /> •See Attached Fire Sprinkler ' 340.17 <br /> HYD STATIC(PSI): 117 BOR STATIC(PSI): 104 <br /> System Acceptance Test Checklist. <br /> RESIDUAL(PSI): 53 HYD ELEVATION(FT): 132.13 <br /> NFPA 13D Report-The installer shall I GRADE1511 55 GRAnF-151 r7 GRADE=151.65 P FLOW(GPM): 1,331 MODEL REPORT DATE:02/03/23 <br /> complete and sign the contractor's material I GRADE=152.5 GRADE=151.6 <br /> and test certificate prior to final approval of SYSTEM SPECIFICATIONS <br /> the system. I w <br /> FFc 15 O BUILDING CODE: 2018 IRC with WA State Amendments C <br /> I_____-_-_-_-_____J Z PqD, 28 SYSTEM TYPE: NFPA 13D 2019 Wet Sprinkler System •e <br /> p 150.g Passive purge system without backflow preventer '> <br /> Oo D 6 O CE G' O © AO SPRINKLER COVERAGE: 256 ftz per sprinkler listing <br /> PUBLICWORKS ODEPARTMENT oocn 1296SF 1221SF 1220SF 1$ZSSF 1525SF 1p?OSF 1220SF 1�20SF 1216SF <br /> SPRINKLER SPACING: 16-0"max.between heads. <br /> BY:THerman <br /> DATE:09110/2024 FFo' FFi�1 FF;i pP�'153.7 FFc' 8'-0"max.from any wall. <br /> CITY OF EVERETT REVIEWED FOR PERMIT PAD=i53 j PAD#15j.3.7 PAD_'S3"5 Ap 151.1 PAD`752'8 8'-0"min.between heads. <br /> 17 7 �t51, 08 <br /> PAD$150.3 PAD,160.3 PAD_150'9 5 Residential fast E response pendent sprinklers used throughout. N d <br /> L........... ............. i............-- ............I r............ ............. �........... ............� HAZARD CLASSIFICATION: <br /> to v <br /> 2666 Residential use throughout. u° <br /> 9 <br /> PIPING DETAILS: o <br /> Blazemas ter CPVC:Aboveground wet sprinkler system throughout except as noted on the F <br /> / Submittal for riser detail. <br /> Bldg C Unit E only s <br /> a <br /> SUPPLY: C m n <br /> N 77°23'09" 6"circulating water main supplies V tap and tube to combined domestic/fire meter.V u m` <br /> E 56.51 combined domestic/water meter supplies 1Yz"poly underground which runs to the system u m <br /> M = <br /> riser. a d Y a <br /> ,...........I ..........., ............ ............ ,.........._ c IY x <br /> LL ai <br /> i ii i E3 <br /> d <br /> LL <br /> CPVC COMPATIBILITY: N <br /> J Iq <br /> A list of approved products for use with Blazemaster CPVC pipe is included with the product <br /> i i i i I specifications booklet For a complete and up-to-date product search lease go to <br /> r...................""", .g <br /> FF: P P <br /> 75 F I p F 1 3 7 pF-153.3 <http://www.moorefire.com/cpvc>Moore Fire Protection is not liable for damage to CPVC c d A <br /> PqD_ 3.7 F=15q 0 ADctS Apc75 piping caused by any products which are not approved for contact with it.Information o. v u <br /> 151.7 PADa75 0 1 7 1 3 about products approved for contact can be found with the manufacturer. 212 <br /> rn d d <br /> FFl1$3 FF, F t no <br /> 2 O 77 A ~ E Y <br /> pAD; 4 PgD53.4 P�153.4 118F 1187 SF 1181 Sp 81 SF GENERAL NOTES AND LIABILITY <br /> 2 T151.q (51.4 A4`151.4 4ti v <br /> Install CPVC piping in accordance with manufacturer's instructions and ILL listing including y m <br /> N+' but not limited to:hanging,vertical restraint,thermal expansion,chemical compatibility, ° n $ <br /> w a O concealment,and protection. Horizontal CPVC pipe shall be concealed with a minimum of 2 m I" n C <br /> v 128 1301 O 3/8"gypsum board. All CPVC pipe shall be concealed. y x u <br /> 2 SF SF 1301 SF GRADE=153.4 GRADE=154.0 a <br /> All system piping is to be supported per manufacturer's specifications and is to be secured <br /> PARCEL NO. SW GRADE=154.0 to to prevent lateral movement. Pipe is to be secured to prevent sprinkler head movement. r_Y <br /> F'>A <br /> 00433600004801 ^�o,�' Moore Fire Protection's warranty of work does not cover any damage due to freeze related ui� OR <br /> - GRADE=153.8 ^N problems. Wet piping shall be protected against temperatures below 50 degrees 999 <br /> ° e only with no insulation on the warm side of the a facing the heated interior. „ .• .' <br /> GRADE=154.8 0 I 2 Fahrenheit. Insulation installed for this purpose shall be located on the cold side of the , <br /> SW GRADE=154.0 pipe y pp g N, ; <br /> Coordinate with general and/or insulation contractor. All insulation to be by others. N <br /> GRADE=155.5 GRADE=155.9 a c 11 <br /> Moore Fire Protection shall not be responsible for the ability of the structure to adequately y ;C t <br /> - O % O support the fire sprinkler system or any appurtenances thereof. <br /> J f <br /> G - 1301 SF 1301 SF 1300 SF Owner is responsible for the periodic inspection,testing and maintenance of the water ;; 5 <br /> - a based fire protection system(s)in accordance with the requirements of NFPA 13D Chaptere� � <br /> 2a O © O O 12. t°k <br /> 1180 118j 118 12 P15 FF; 8, FFk 15 <br /> �m jl FF=7572 FF S FF 757 FFf�6 pAtl`156.3 PAD, 66 3 PAD'156.3 • lJh"Poly or equivalent supply brought in by others.* :�... ... .. <br /> Pgtl`758.2 PAD,i552 PA��7556 PAD,'S 11@"combination domestic/fire sprinkler shut off valve C:) M M #z <br /> 2 : ? by others.Must be located before the domestic tee. J <br /> I s b O x <br /> a 10 <br /> �- r No monitoring is required. N .a <br /> i i i a <br /> o es # v N U� <br /> �� ----... tic Ares - o ngtva v <br /> E 11/z"to nues to d by others.Any <br /> domes sure redu Ives,water softeners, ,�E O <br /> roc 1 = O leak detectors,or other devices that will deter water m J v --0 <br /> ........ ............' `.....---... ............, i i <br /> 3 •Flow are to be on the domestic-only side of the tee. O w v o t n 2: <br /> 0o u.u Brass tee top outlet to be female-threaded to d w o In <br /> w " O n accommodate male threaded CPVC adapter �� m o v <br /> om� G G u connection. V) N o oo w <br /> O.i Q o 7 J <br /> C a �0 1%"PEX to domestic by others. N 3 M O N <br /> g hh"CPVC adapter with 11/2xl CPVC reducing bushing. LU LL1 ry v Z <br /> O MFP scope of work to begin here. 2 E o < o <br /> 1"check valve. V)Q d u ui <br /> w v <br /> LU It m o`, <br /> N 76°16'48"E - _ r ` ® 1"tee with flow switch wired to exterior bell by .--I(A o w a In 10 w <br /> others. <br /> 220.10 E v Z M <br /> c ul a 1"x 1"x 1"tee with 1"drain valve piped to collection ` 1 <br /> u cup attached to sanitary sewer,left by plumber and 0 U o, <br /> ® co <br /> sized to accommodate the system flow demand of 27 '^ < <br /> a O d gpm. V ?i <br /> SITE PLAN UNDERGROUND NOTES A m O 1"x 1"x/z"tee with h"x va"bushing for pressure u <br /> SCALE:1/16"=1'-0" 16 All underground to be by others. .r 9auge.Three way valve included for pressure gauge. 11 I M w <br /> ❑A Modelled hydrant Flow location RISER SECTION KEYNOTE LEGEND LU y <br /> SCALE:1/2"=V-0" O '^ j <br /> ❑B 6-in circulating water main • Part Tag `QJ U <br /> WARNING SIGN: STUB IN: <br /> v <br /> 6.3.4 A warning sign,with minimum 1/4 in.letters,shall be affixed adjacent to the main *Builder to Provide 12"x 12"block out to protect piping. O w Cal❑C Tap to 1-in combined domestic/fire service(Typical for all units) shutoff valve and shall state the following: # Hydraulic Node Tag <br /> FLUSH TEST: �/ 'a <br /> WARNING:The water system for this home supplies fire sprinklers that require certain Underground installer will be required to have a flush test completed and witnessed L,L <br /> m <br /> ❑D 1-in combined domestic/fire meter(Typical for all units) flows and pressures to fight a fire.Devices that restrict the flow or decrease the pressure before Moore Fire will hook up to the incoming supply.Underground installer to provide a O Reference Tag <br /> or automatically shut off the water to the fire sprinkler system,such as water softeners, CMTC proving this test was done. LL O _ <br /> filtration systems,and automatic shutoff valves,shall not be added to this system without PASSIVE PURGE SYSTEM SPECIAL NOTES: y <br /> ❑# Underground Note Tag 00 <br /> ❑E lYz-in poly combined domestic/fire underground to riser location by others*(Typical for all units) a review of the fire sprinkler system by a fire protection specialist. This is aFlow-through("passive purge")system.A 1h"female adapter will be left at the � E <br /> remote toilet location.Plumber is to connect from adapter to toilet. 3: <br /> Do not remove this sign. �# Remote Area Tag Q O <br /> ❑F Riser location-see this page for detail(Typical for all units) T ^/ <br /> M <br />